Literature DB >> 15653966

Choice of oximeter affects apnea-hypopnea index.

Subooha Zafar1, Indu Ayappa, Robert G Norman, Ana C Krieger, Joyce A Walsleben, David M Rapoport.   

Abstract

STUDY
OBJECTIVES: Current Medicare guidelines include an apnea-hypopnea index (AHI) > or = 15 events per hour, in which all hypopneas must be associated with 4% desaturation, to qualify for reimbursement for therapy with continuous positive airway pressure (CPAP). The present data demonstrate the effect of pulse oximeter differences on AHI.
DESIGN: Prospective study, blinded analysis.
SETTING: Academic sleep disorder center. PATIENTS: One hundred thirteen consecutive patients (84 men and 29 women) undergoing diagnostic sleep studies and being evaluated for CPAP based on the Medicare indications for reimbursement.
INTERVENTIONS: Patients had two of four commonly used oximeters with signal averaging times of 4 to 6 s placed on different digits of the same hand during nocturnal polysomnography. MEASUREMENTS AND
RESULTS: Apneas and candidate hypopneas (amplitude reduction, > 30%) were scored from the nasal cannula airflow signal without reference to oximetry. Candidate hypopneas then were reclassified as hypopneas by each oximeter if they were associated with a 4% desaturation. Although the use of three oximeters resulted in a similar AHI (bias, < 1 event per hour), the fourth oximeter showed an overall increase in AHI of 3.7 events per hour. This caused 7 of 113 patients to have an AHI of > or = 15 events per hour (meeting the Medicare criteria for treatment) by one oximeter but not when a different oximeter was used. More importantly, when our analysis was limited to those patients whose number of candidate hypopneas made them susceptible to the threshold value of 15 events per hour, 7 of 35 patients who did not meet the Medicare AHI standard for treatment by one oximeter were reclassified when a different oximeter was used.
CONCLUSION: In the present study, oximeter choice affected whether the AHI reached the critical cutoff of 15 events per hour, particularly in those with disease severity that was neither very mild nor very severe. As oximetry is not a technique that produces a generic result, there are significant limitations to basing the definition of hypopnea on a fixed percentage of desaturation in determining the eligibility for CPAP therapy.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15653966     DOI: 10.1378/chest.127.1.80

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  16 in total

1.  Novel mathematical processing method of nocturnal oximetry for screening patients with suspected sleep apnoea syndrome.

Authors:  Laurent Poupard; Carole Philippe; Michael David Goldman; Richard Sartène; Marc Mathieu
Journal:  Sleep Breath       Date:  2011-04-15       Impact factor: 2.816

2.  Abbreviated or not abbreviated? Is it the right question?

Authors:  Frederic Sériès
Journal:  Thorax       Date:  2007-05       Impact factor: 9.139

3.  Positive Home Sleep Apnea Test After a Negative Polysomnogram: Role of Potential Confounding Factors.

Authors:  Mukesh Kapoor
Journal:  J Clin Sleep Med       Date:  2019-03-15       Impact factor: 4.062

4.  The Importance of State and Context in Safe Interoperable Medical Systems.

Authors:  Sandy Weininger; Michael B Jaffe; Michael Robkin; Tracy Rausch; David Arney; Julian M Goldman
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-08       Impact factor: 3.316

5.  The Need to Apply Medical Device Informatics in Developing Standards for Safe Interoperable Medical Systems.

Authors:  Sandy Weininger; Michael B Jaffe; Julian M Goldman
Journal:  Anesth Analg       Date:  2017-01       Impact factor: 5.108

6.  Comparison of two home sleep testing devices with different strategies for diagnosis of OSA.

Authors:  Tyler Gumb; Akosua Twumasi; Shahnaz Alimokhtari; Alan Perez; Kathleen Black; David M Rapoport; Jag Sunderram; Indu Ayappa
Journal:  Sleep Breath       Date:  2017-08-19       Impact factor: 2.816

7.  Prevalence and severity of sleep apnea in a group of morbidly obese patients.

Authors:  Carla Daltro; Paloma Baiardi Gregorio; Erivaldo Alves; Maurício Abreu; Daniel Bomfim; Maria Helena Chicourel; Leila Araújo; Helma P Cotrim
Journal:  Obes Surg       Date:  2007-06       Impact factor: 4.129

8.  Validation of a self-applied unattended monitor for sleep disordered breathing.

Authors:  Indu Ayappa; Robert G Norman; Vijay Seelall; David M Rapoport
Journal:  J Clin Sleep Med       Date:  2008-02-15       Impact factor: 4.062

9.  Validation of the WristOx 3100 oximeter for the diagnosis of sleep apnea/hypopnea syndrome.

Authors:  Carlos Alberto Nigro; Silvia Aimaretti; Sergio Gonzalez; Edgardo Rhodius
Journal:  Sleep Breath       Date:  2008-10-02       Impact factor: 2.816

10.  High Interrater Reliability of Overnight Pulse Oximetry Interpretation Among Inexperienced Physicians Using a Structured Template.

Authors:  Mirna Ayache; Kingman P Strohl
Journal:  J Clin Sleep Med       Date:  2018-04-15       Impact factor: 4.062

View more