Synthetic Patch Rotator Cuff Repair: A 10-year Follow-Up.

Henry M Shepherd1, Patrick H Lam1, George A C Murrell1.   

Abstract

BACKGROUND: The present study aimed to determine the long-term outcome as a result of the use of synthetic patches as tendon substitutes to bridge massive irreparable rotator cuff defects.
METHODS: All patients who previously had a rotator cuff repair with a synthetic patch (2-mm Gore DUALMESH ePTFE patch; Gore, Flagstaff, AZ, USA; or a 2.87-mm Bard PTFE Felt pledgets; CR Bard, Warwick, RI, USA) were followed-up at a minimum of 8.5 years postoperatively. Assessment of shoulder pain, function, range of motion, strength and imaging was performed.
RESULTS: Six patients had an interpositional repair with a synthetic patch. One patient had died. In the remaining five patients, the mean tear size at repair was 27 cm(2). At 9.7 years postoperatively, all the patches remained in situ and no patient required further surgery. The repair was intact in four out of five patients. Patients had improved external rotation and abduction compared to before surgery (p < 0.02).
CONCLUSIONS: We describe the long-term outcomes of patients who had undergone synthetic patch rotator cuff repair for an irreparable rotator cuff tear. At 9.7 years postoperatively, patients reported less severe and more infrequent pain, as well as greater overall shoulder function, compared to before surgery. Patients also had increased passive external rotation and abduction. All the patches remain in situ and there have been no further operations on these shoulders.

Entities:  

Keywords:  Shoulder; graft; rotator cuff; rotator cuff repair; synthetic patch

Year:  2013        PMID: 27582907      PMCID: PMC4986658          DOI: 10.1111/sae.12046

Source DB:  PubMed          Journal:  Shoulder Elbow        ISSN: 1758-5732


  26 in total

1.  Reliability of five methods for assessing shoulder range of motion.

Authors:  K Hayes; J R Walton; Z R Szomor; G A Murrell
Journal:  Aust J Physiother       Date:  2001

2.  Augmentation with a Gore-Tex patch for repair of large rotator cuff tears that cannot be sutured.

Authors:  Atsushi Hirooka; Minoru Yoneda; Shigeyuki Wakaitani; Yoshiteru Isaka; Kenji Hayashida; Sunao Fukushima; Kenji Okamura
Journal:  J Orthop Sci       Date:  2002       Impact factor: 1.601

3.  The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears.

Authors:  Leesa M Galatz; Craig M Ball; Sharlene A Teefey; William D Middleton; Ken Yamaguchi
Journal:  J Bone Joint Surg Am       Date:  2004-02       Impact factor: 5.284

4.  Early aseptic loosening of a total knee arthroplasty due to Gore-Tex particle-induced osteolysis.

Authors:  Michael D Miller; Christopher L Peters; Bryce Allen
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

5.  The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique.

Authors:  Laurent Lafosse; Roman Brozska; Bruno Toussaint; Reuben Gobezie
Journal:  J Bone Joint Surg Am       Date:  2007-07       Impact factor: 5.284

6.  Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff.

Authors:  D T Harryman; L A Mack; K Y Wang; S E Jackins; M L Richardson; F A Matsen
Journal:  J Bone Joint Surg Am       Date:  1991-08       Impact factor: 5.284

7.  A self-administered questionnaire for assessment of symptoms and function of the shoulder.

Authors:  J C L'Insalata; R F Warren; S B Cohen; D W Altchek; M G Peterson
Journal:  J Bone Joint Surg Am       Date:  1997-05       Impact factor: 5.284

8.  Gross osteolytic tibia tunnel widening with the use of Gore-Tex anterior cruciate ligament prosthesis: a radiological, arthrometric and clinical evaluation of 17 patients 13-15 years after surgery.

Authors:  Olle Muren; Lars Dahlstedt; Eva Brosjö; Mats Dahlborn; Nils Dalén
Journal:  Acta Orthop       Date:  2005-04       Impact factor: 3.717

9.  Biologic anchorage of cruciate ligament prosthesis. Bone ingrowth and fixation of the Gore-Tex ligament in sheep.

Authors:  P Paavolainen; S Mäkisalo; K Skutnabb; T Holmström
Journal:  Acta Orthop Scand       Date:  1993-06

10.  Functional and anatomical results after rotator cuff repair.

Authors:  D F Gazielly; P Gleyze; C Montagnon
Journal:  Clin Orthop Relat Res       Date:  1994-07       Impact factor: 4.176

View more
  3 in total

Review 1.  Patch Augmentation in Rotator Cuff Repair.

Authors:  Peter N Chalmers; Robert Z Tashjian
Journal:  Curr Rev Musculoskelet Med       Date:  2020-10

2.  Biomechanical comparison of expanded polytetrafluoroethylene (ePTFE) and PTFE interpositional patches and direct tendon-to-bone repair for massive rotator cuff tears in an ovine model.

Authors:  Andrew Dj McKeown; Rebekah F Beattie; George Ac Murrell; Patrick H Lam
Journal:  Shoulder Elbow       Date:  2015-09-08

3.  A Comparison of Two Arthroscopic Techniques for Interpositional Polytetrafluoroethylene Patch Repair for Massive Irreparable Rotator Cuff Tears: Speed and Biomechanics.

Authors:  Joo Y Sunwoo; Patrick H Lam; George A C Murrell
Journal:  HSS J       Date:  2018-03-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.