Literature DB >> 14960664

The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears.

Leesa M Galatz1, Craig M Ball, Sharlene A Teefey, William D Middleton, Ken Yamaguchi.   

Abstract

BACKGROUND: The impact of a recurrent defect on the outcome after rotator cuff repair has been controversial. The purpose of this study was to evaluate the functional and anatomic results after arthroscopic repair of large and massive rotator cuff tears with use of ultrasound as an imaging modality to determine the postoperative integrity of the repair.
METHODS: Eighteen patients who had complete arthroscopic repair of a tear measuring >2 cm in the transverse dimension were evaluated at a minimum of twelve months after surgery and again at two years after surgery. The evaluation consisted of a standardized history and physical examination as well as calculation of the preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons. The strength of both shoulders was quantitated postoperatively with use of a portable dynamometer. Ultrasound studies were performed with use of an established and validated protocol at a minimum of twelve months after surgery.
RESULTS: Recurrent tears were seen in seventeen of the eighteen patients. Despite the absence of healing at twelve months after surgery, thirteen patients had an American Shoulder and Elbow Surgeons score of >/=90 points. Sixteen patients had an improvement in the functional outcome score, which increased from an average of 48.3 to 84.6 points. Sixteen patients had a decrease in pain, and twelve had no pain. Although eight patients had preoperative forward elevation to <95 degrees, all eighteen regained motion above shoulder level and had an average of 152 degrees of elevation. At the second evaluation, a minimum of twenty-four months after surgery, the average score, according to the system of the American Shoulder and Elbow Surgeons, had decreased to 79.9 points; only nine patients had a score of >/=90 points, and six patients had a score of </=79 points. The average forward elevation decreased to 142 degrees.
CONCLUSIONS: Arthroscopic repair of large and massive rotator cuff tears led to a high percentage of recurrent defects. The minimum twelve-month evaluation showed excellent pain relief and improvement in the ability to perform activities of daily living despite the high rate of recurrent defects; however, at a minimum follow-up of two years, the results deteriorated with only twelve patients who had an American Shoulder and Elbow Surgeons score of >/=80.

Entities:  

Mesh:

Year:  2004        PMID: 14960664     DOI: 10.2106/00004623-200402000-00002

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  451 in total

1.  Development of fatty atrophy after neurologic and rotator cuff injuries in an animal model of rotator cuff pathology.

Authors:  Kasra Rowshan; Scott Hadley; Khoa Pham; Vince Caiozzo; Thay Q Lee; Ranjan Gupta
Journal:  J Bone Joint Surg Am       Date:  2010-10-06       Impact factor: 5.284

2.  Effect of implanting a soft tissue autograft in a central-third patellar tendon defect: biomechanical and histological comparisons.

Authors:  Kirsten R C Kinneberg; Marc T Galloway; David L Butler; Jason T Shearn
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

3.  Arthroscopic transosseous (anchorless) rotator cuff repair.

Authors:  Raffaele Garofalo; Alessandro Castagna; Mario Borroni; Sumant G Krishnan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-20       Impact factor: 4.342

4.  Biologic augmentation of rotator cuff repair.

Authors:  Scott R Montgomery; Frank A Petrigliano; Seth C Gamradt
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

Review 5.  Rotator cuff: biology and current arthroscopic techniques.

Authors:  Olaf Lorbach; Marc Tompkins
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-21       Impact factor: 4.342

6.  Influence of the initial rupture size and tendon subregion on three-dimensional biomechanical properties of single-row and double-row rotator cuff reconstructions.

Authors:  O Lorbach; D Pape; F Raber; L C Busch; D Kohn; M Kieb
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-11       Impact factor: 4.342

7.  Stitch positioning influences the suture hold in supraspinatus tendon repair.

Authors:  Karl Wieser; Stefan Rahm; Mazda Farshad; Eugene T Ek; Christian Gerber; Dominik C Meyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-17       Impact factor: 4.342

Review 8.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

Review 9.  Cellular therapy in bone-tendon interface regeneration.

Authors:  Benjamin B Rothrauff; Rocky S Tuan
Journal:  Organogenesis       Date:  2013-12-09       Impact factor: 2.500

10.  Award Winner in the Young Investigator Category, 2014 Society for Biomaterials Annual Meeting and Exposition, Denver, Colorado, April 16-19, 2014: Periodically perforated core-shell collagen biomaterials balance cell infiltration, bioactivity, and mechanical properties.

Authors:  Steven R Caliari; Laura C Mozdzen; Oliver Armitage; Michelle L Oyen; Brendan A C Harley
Journal:  J Biomed Mater Res A       Date:  2013-12-31       Impact factor: 4.396

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.