Anatomic stemless shoulder arthroplasty and related outcomes: a systematic review.

Nael Hawi1,2, Mark Tauber3,4, Michael Joseph Messina3,5, Peter Habermeyer3, Frank Martetschläger3,6.   

Abstract

BACKGROUND: The latest generation of shoulder arthroplasty includes canal-sparing respectively stemless designs that have been developed to allow restoration of the glenohumeral center of rotation independently from the shaft, and to avoid stem-related complications. The stemless prosthesis design has also recently been introduced for use in reverse arthroplasty systems.
METHODS: We systematically reviewed the literature for studies of currently available canal-sparing respectively stemless shoulder arthroplasty systems. From the identified series, we recorded the indications, outcome measures, and humeral-sided complications.
RESULTS: We identified 11 studies of canal-sparing respectively stemless anatomic shoulder arthroplasty implants, published between 2010 and 2016. These studies included 929 cases, and had a mean follow-up of 26 months (range, 6 to 72 months). The rates of humeral component-related complications ranged between 0 and 7.9 %. The studies reported only a few isolated cases of complications of the humeral component. Some arthroplasty systems are associated with radiological changes, but without any clinical relevance.
CONCLUSIONS: All of the published studies of canal-sparing respectively stemless shoulder arthroplasty reported promising clinical and radiological outcomes in short to midterm follow-up. Long-term studies are needed to demonstrate the long-term value of these kind of implants.

Entities:  

Keywords:  Canal-sparing; Posttraumatic shoulder arthritis; Shoulder arthritis; Shoulder arthroplasty; Stemless; Total shoulder arthroplasty

Mesh:

Year:  2016        PMID: 27577859      PMCID: PMC5006279          DOI: 10.1186/s12891-016-1235-0

Source DB:  PubMed          Journal:  BMC Musculoskelet Disord        ISSN: 1471-2474            Impact factor:   2.362


Background

Early development of shoulder arthroplasty can be traced back to 1950s when Charles Neer, II, described the use of an implant to treat a proximal humeral fracture [1]. Eventually, the indication was widened to include osteoarthritis treatment. Since Neer’s initial prosthesis, the humeral stem design has undergone several changes. Results of total shoulder arthroplasty were first presented in 1974 [2]. The following years saw the introduction of several variations of stemmed humeral implants, which could be subdivided into four different generations. Stem design initially used a monoblock system, then changed to a modular system, followed by a shift to the use of shorter stems. Additionally, cemented fixation techniques have been replaced over time by a press-fit cementless system. The use of shorter implant stems and the elimination of humeral cement carry several advantages, including the preservation of humeral bone stock for potential revisions, performance of anatomic reconstruction regardless of posterior offset in anatomic arthroplasty, facilitating arthroplasty in cases of humeral deformity, prevention of malpositioning, and avoiding periprosthetic fractures [3]. Commonly reported stem-related complications include intraoperative humeral fracture, loosening, stress shielding, and traumatic periprosthetic fracture [4-11]. Fracture sequelae, including severe shaft-head malunion, can lead to malalignment of the shaft implantation and a failure to restore the anatomic center of rotation. In revision surgery, stem removal can present a challenge for the surgeon, potentially requiring an osteotomy or inadvertently resulting in an intraoperative fracture [5, 6, 8, 11]. Canal-sparing respectively stemless prostheses were first available in Europe in 2004. Such implants lack a conventional diaphyseal humeral stem, are based on metaphyseal fixation, and do not violate the humeral canal. In this review article, the terms “canal-sparing” respectively “stemless” refer to implant designs with metaphyseal fixation using a standard humeral neck cut, and excluding humeral head resurfacing techniques. Canal-sparing respectively stemless shoulder arthroplasty must not be confused with resurfacing techniques that aim to restore joint congruency by preserving the majority of the humeral head bone stock and implantation of a metallic cap over the remaining humeral head bone stock [3, 12–18]. Here we have systematically reviewed the current literature describing canal-sparing respectively stemless prostheses in shoulder arthroplasty, particularly with regards to clinical outcomes and complications related to the humeral components.

Methods

The senior investigator (FM) and first author (NH) systematically scanned an online database system (Pubmed, Google Scholar) using the MeSH terms “stemless”, “shoulder replacement”, “shoulder arthroplasty”, “canal-sparing”, and “short stem”. Then the resulting list of references was reviewed to identify potential additional studies. Inclusion criteria were clinical studies including more than five patients, using cementless and stemless humeral fixation, and presenting outcomes and complications. Statistical analysis was ineffective due to the small number of cases, as well as the use of different follow-up protocols, study designs, and outcome measures. Therefore, we performed a descriptive review, with information presented according to the different investigated prosthetic designs. For all included series, we recorded and summarized the indications, outcome measures (clinical and radiological), and complications. The scoring systems of the different studies are presented systematically. Only complications related to the humeral component are included.

Results

Our findings are summarized in Tables 1, 2, 3, 4 and 5.
Table 1

Included patients and follow-up

Implantn = included stemlessAge (years, mean)FU (months, mean)
2010Huguet et al.JSESTESS636445.2
2013Razmjou et al.JSESTESS176924
2013Berth et PapJOTTESS416730.8
2015Maier et al.BMCTESS12686
2011Kadum et al.AOTSTESS227114
2014Bell et CoghlanInt J Shoulder SurgMathys Affinis386812
126524
2011Schoch et al.Obere ExtremitaetArthrex Eclipse966613.2
1962
2012Brunner et al.Obere ExtremitaetArthrex Eclipse2336123.2
2015Habermeyer et al.JSESArthrex Eclipse785872
2016Ho et al.JSESSimpliciti1496624
2016Churchill et al.JBJSSimpliciti1496624
Table 2

Indication for stemless arthroplasty treatment

ImplantN (stemless)Primary osteoarthritisPosttraumatic osteoarthritisOsteo-necrosisRheumatoid arthritisCTAMRCTInstability arthritisPost infection arthtisArthritis due to glenoid dysplasiaRevision
2010Huguet et al.JSESTESS63603
2013Razmjou et al.JSESTESS1717
2013Berth et PapJOTTESS4141
2015Maier et al.BMCTESS1212
2011Kadum et al.AOTSTESS22193
2014Bell et CoghlanInt J Shoulder SurgMathys Affinis5050
2011Schoch et al.Obere ExtremitaetArthrex Eclipse1159619
2012Brunner et al.Obere ExtremitaetArthrex Eclipse2331007061632945 cases couldn’t assigned
2015Habermeyer et al.JSESArthrex Eclipse7839263811
2016Ho et al.JSESSimpliciti149Not specified
2016Churchill et al.JBJSSimpliciti14996 %4 %
Table 3

Kind of stemless arthroplasty treatment and approach

ImplantnApproachHemiarthroplastyTotal shoulder arthroplasty
2010Huguet et al.JSESTESS63Deltopectoral4419
2013Razmjou et al.JSESTESS17Deltopectoral17
2013Berth et PapJOTTESS41Deltopectoral41
2015Maier et al.BMCTESS12Deltopectoral12
2011Kadum et al.AOTSTESS22Antero-Superior (Mackenzie)Not assigned
2014Bell et CoghlanInt J Shoulder SurgMathys Affinis50Deltopectoral50
2011Schoch et al.Obere ExtremitaetArthrex Eclipse115Deltopectoral115
2012Brunner et al.Obere ExtremitaetArthrex Eclipse233Deltopectoral114119
2015Habermeyer et al.JSESArthrex Eclipse78Deltopectoral3939
2016Ho et al.JSESSimpliciti149Deltopectoral149
2016Churchill et al.JBJSSimpliciti149Deltopectoral149
Table 4

Humeral implant related complication

ImplantnPercentage of complicationKind of stemless humeral implant related complication and treatment
2010Huguet et al.JSESTESS637.9 %- Five patients with a small crack of the humeral lateral cortex intraoperatively, noticed on the first postoperative radiograph, further conservative treatment
2013Razmjou et al.JSESTESS170 %-
2013Berth et PapJOTTESS410 %-
2015Maier et al.BMCTESS120 %-
2011Kadum et al.AOTSTESS220 %-
2014Bell et CoghlanInt J Shoulder SurgMathys Affinis500 %-
2011Schoch et al.Obere ExtremitaetArthrex Eclipse1150 %-
2012Brunner et al.Obere ExtremitaetArthrex Eclipse2332.3 %- One patient with radiological and asymptomatic loosening after 24 months
2015Habermeyer et al.JSESArthrex Eclipse780 %-
2016Ho et al.JSESSimpliciti1490 %-
2016Churchill et al.JBJSSimpliciti1490 %-
Table 5

Outcome parameters with radiological humeral conspicuous findings (values are given in mean if not declared different)

2010Huguet et al.JSESTESS63Constant scoreAnterior active elevation (°)ER with elbow to the side (°)Radiological humeral component outcome
29.675961452040Inconspicuous
2013Razmjou et al.JSESTESS17Quick dashWOOSASESInconspicuous
542337854182
Relative Constant-Murley ScoreFlexion (°)Abduction (°)
37926913551121
ER in neutral (°)ER 90° abduction (°)IR at 90° abduction (°)
1854961133
Strength (lbs)
510
2013Berth et PapJOTTESS41DASH score (points)Constant score, adjusted (points)Anteversion (°)Inconspicuous
62.147.440.173.281.2115.9
Abduction (°)External rotation (°)
68.210539.154.4
2015Maier et al.BMCTESS12Constant scoreFlexion (°)Abduction (°)-
33.74894.296.979.685.9
2011Kadum et al.AOTSTESS anatomic22Quick dashEQ-5DVAS for life of qualityInconspicuous
TESS reverse17
56340.360.733966
2014Bell et CoghlanInt J Shoulder SurgMathy Affinis50Constant scoreDASH scoreASES scoreInconspicuous
3828.8476.1249.3610.7942.5188.28
1224.8285.7548.805.9446.3992.58
SPADI scoreActive elevation (median) (°)
3864.2811.0575160
1260.635.1693.18160
2011Schoch et al.Obere ExtremitaetArthrex Eclipse115Constant Murley scoreAnteversion (°)Abduction (°)Inconspicuous
9644.76611814582105
1934.65711014075100
External rotation (°)
961541
191538
2012Brunner et al.Obere ExtremitaetArthrex Eclipse233Constant Murley score (%)Flexion (°)Abduction (°)7.2 % of cases radiolucency between the head and the screw without clinical consequences
51.678.910512880120
External rotation (°)
2237
2015Habermeyer et al.JSESArthrex Eclipse78Constant Murley score (%)Flexion (°)Abduction (°)Incomplete radiolucent line of the humeral component smaller than 2 mm in one patient, in three patients partial osteolyses under the superior part of the humeral component without loosening, decreased density of cancellous bone in the greater tuberosity with the AP view in 34.9 % without influence on shoulder function.
38.175.311414174130
External rotation (°)
2544
2016Ho et al.JSESSimpliciti149Constant Murley score (adjusted)Constant Murley score (adjusted)Constant Murley score (adjusted)Inconspicuous
<60 y60–69 y>70 y
51.290.555.9105.658.2110.6
ASES scoreASES scoreASES score
<60 y60–69 y>70 y
33.284.139.694.339.193.1
Simple shoulder testSimple shoulder testSimple shoulder test
<60 y60–69 y>70 y
410.14.3114.610.7
External rotation (°)External rotation (°)External rotation (°)
<60 y60–69 y>70 y
35.454.928.855.831.358.2
Scapular plane (°)Scapular plane (°)Scapular plane (°)
<60 y60–69 y>70 y
107.1142.4102.3149.6100.9144.5
2016Churchill et al.JBJSSimpliciti149Constant Murley Score (adjusted, %)ASES scoreSimple shoulder TestInconspicuous
55.6104.138.291.94.310.8
Pain VAS ScoreScapular plane (°)Eternal rotation (°)
5.90.5102.8146.630.956.4
Included patients and follow-up Indication for stemless arthroplasty treatment Kind of stemless arthroplasty treatment and approach Humeral implant related complication Outcome parameters with radiological humeral conspicuous findings (values are given in mean if not declared different)

Biomet Total Evolutive Shoulder System

The first available canal-sparing respectively stemless implant was the Biomet Total Evolutive Shoulder System (TESS, Biomet, Warsaw, IN, USA), which was first used in Europe in 2004 (Fig. 1). The TESS is a three-component system, which includes an impaction-implanted 6-armed corolla that is porous to improve bone ingrowth. We identified five studies using the TESS, which were published between 2010 and 2016, and included a total of 155 patients. Follow-up times ranged from 6 to 45 months. Table 2 presents the surgical indications. All studies showed clinical improvement after arthroplasty compared to the preoperative status.
Fig. 1

The Biomet Total Evolutive Shoulder System (TESS; Biomet, Warsaw, IN, USA) (Figure provided by the manufacturer)

The Biomet Total Evolutive Shoulder System (TESS; Biomet, Warsaw, IN, USA) (Figure provided by the manufacturer) In 2010, Huguet et al. [19] first reported on 63 cases with a minimum follow-up of three years. Concerning the TESS stemless humeral implant, the authors report that in five cases the lateral cortex cracked during surgery without any sign of instability, and that each of these cases healed without further intervention. No other humeral implant-associated complications or problems were noted. The remaining four identified studies reported no complications related to the TESS humeral implant. Kadum et al. [20] analyzed 56 patients, among whom 22 received an anatomic TESS prosthesis, with a mean follow-up of 14 months. Razmjou et al. [21] compared the anatomic TESS prosthesis (n = 17) to the Bigliani-Flatow (n = 40) and the Neer II prosthesis (n = 22), showing no significant differences in outcome between groups, with a mean follow-up of 24 months. Berth and Pap [22] compared the anatomic TESS prosthesis to the Mathys Affinis stemmed prosthesis, with 41 patients in each group and a mean follow-up of 30 months. Their results revealed no statistically significant differences in outcome. Finally, Meier et al. [23] compared the anatomic TESS prosthesis to the anatomic stemmed Aequalis Shoulder prosthesis (Tournier, Lyon, France), with 12 cases per group and a 6-month follow-up. They reported comparable results for both groups based on the Constant Score.

Mathys Affinis Short Stemless Prosthesis

The Mathys Affinis Short Stemless Prosthesis (Mathys, Betlach, Switzerland) was first available on the European market in 2009 (Fig. 2). This arthroplasty system has two components: a humeral metaphyseal implant and a ceramic humeral head. The metaphyseal implant comprises four wings composed of a rough porous titanium structure, with an osteoconductive calcium phosphate coating to improve bone ingrowth. This part is inserted with impaction.
Fig. 2

The Mathys Affinis Short Stemless Prosthesis (Mathys, Betlach, Switzerland) (Figure provided by the manufacturer)

The Mathys Affinis Short Stemless Prosthesis (Mathys, Betlach, Switzerland) (Figure provided by the manufacturer) In the only published study using this implant, Bell and Coghlan [24] investigated 50 cases with an indication of primary osteoarthritis. They reported a 24-month follow-up for 12 cases, and a 12-month follow-up for 38 cases. No prosthesis-related intraoperative or postoperative complications were reported.

Arthrex Eclipse Prosthesis

The Arthrex Eclipse Prosthesis (Arthrex, Naples, USA) was introduced in 2005 (Fig. 3). This prosthesis comprises three components. A fully threaded, cylindrical central cage unit is inserted over a collar-bearing baseplate (trunnion) for metaphyseal fixation. The trunnion covers the resection plane at the anatomical neck, and joins cortical support. The third component is a corresponding humeral head. In contrast to the other described implants, the Arthrex Eclipse is the only available stemless system that offers screw-in insertion.
Fig. 3

The Arthrex Eclipse Prosthesis (Arthrex, Naples, USA) (Figure provided by the manufacturer)

The Arthrex Eclipse Prosthesis (Arthrex, Naples, USA) (Figure provided by the manufacturer) Between 2011 and 2015, three studies investigated the Eclipse prosthesis, including a total of 426 procedures with a mean follow-up ranging from 13 to 72 months. Table 2 presents the specific surgical indications. Schoch et al. [25] analyzed 115 cases, and reported that all of the radiographs evaluated at the 12-month follow-up were inconspicuous with regards to loosening or radiolucent lines. Brunner et al. [26] published their experience of using the Eclipse prosthesis in 233 patients after a mean follow-up of 23 months. They describe one case in which the implant loosened after 24 months, and they noted radiolucency between the head and the screw in 7.2 % of cases. However, these radiological changes did not appear to have any clinical relevance. In the most recent study of the Eclipse prosthesis, Habermeyer et al. [27] analyzed 78 patients with a minimum follow-up of 5 years. They reported that one patient showed an incomplete radiolucent line of the humeral component of smaller than 2 mm. Additionally, three patients exhibited partial osteolysis under the superior part of the humeral component, without loosening of the component. Among the patients, 34.9 % showed changed cancellous bone density in terms of stress shielding at the greater tuberosity on the AP view, without clinical significance. No implant-specific complications were observed related to the Eclipse prosthesis.

Simpliciti Stemless Prosthesis

Clinical use of the Simpliciti Stemless Prosthesis (Tornier, Bloomington, MN, US) began in France in 2010 (Fig. 4). It is presently the only FDA-approved stemless respectively canal-sparing implant. It comprises two pieces—a humeral implant and a head implant—which are available in different sizes. Churchill et al. [27] and Ho et al. [18, 28] both recently published results of canal-sparing respectively stemless shoulder arthroplasty with a 24-month follow-up in a total of 298 patients. Table 2 summarizes the indications. Both studies demonstrated improved outcomes, and no humeral-sided complications.
Fig. 4

The Simpliciti Stemless Prosthesis (Tornier, Bloomington, MN, US) (Figure provided by the manufacturer)

The Simpliciti Stemless Prosthesis (Tornier, Bloomington, MN, US) (Figure provided by the manufacturer)

Discussion

Six different canal-sparing respectively stemless humeral implants are presently available on the market, four of which are described in published studies. The canal-sparing respectively stemless shoulder prosthesis with metaphyseal anchoring is a relatively new concept that reportedly provides good outcomes that are comparable to stemmed designs in short and midterm evaluations [19, 21–23, 27]. All of the presently reviewed studies demonstrated substantial improvement after replacement. Moreover, the studies that compared the canal-sparing respectively stemless design to stemmed implants showed no differences in outcomes related to the humeral component [21-23]. The indications for canal-sparing respectively stemless prosthesis are the same as for stemmed systems. Canal-sparing respectively stemless implants cannot be used in cases with poor bone quality, metaphyseal cysts, osteopenia, osteoporosis, or other metabolic bone diseases [29], or in cases with fractures in the metaphyseal area that disturb adequate bony in-growth or primary implant stability. However, there is not yet any test available to objectively determine bone quality pre- or intraoperatively [29]. Churchill et al. [18] described the use of a “thumb test” in which bone quality is intraoperatively assessed by compressing the surface of the neck cut with the thumb. Overall, the presently reviewed studies reported only a few isolated cases of loosening of the stemless component. Among the various investigated canal-sparing respectively stemless prostheses, the main difference in design is that the Eclipse is inserted over a screw, while the TESS, the Simpliciti, and the Affinis prostheses are inserted using an impaction technique. It appears that the mechanism of force transmission when the Eclipse prosthesis is inserted over a screw differs from that during impaction implantation of the corolla of the TESS, the wings of the Affinis, or the Simpliciti prosthesis. This difference may explain the observed differences in the surrounding humeral bone, with changed bone mineral density seen on radiographs, which could be interpreted as stress shielding beneath the trunnion with the Eclipse prosthesis. These findings are not correlated with any negative clinical symptoms, and seem to be purely a radiographic phenomenon, at least at the midterm follow-up. Subgroup analysis of these patients reported by Habermeyer et al. [27] revealed no statistical significance in the patient cohort, with a minimum follow-up of 5 years. One major advantage of the canal-sparing respectively stemless prosthesis design is that it can potentially be used in post-traumatic and deformity cases regardless of the humeral head–shaft configuration. Restoration of the glenohumeral center of rotation independently from the shaft is a key goal in secondary shoulder arthroplasty for fracture sequelae treatment [30]. Malunion resulting in metaphyseal–diaphyseal malalignment can make it difficult or even impossible to implant a stemmed or even a short-stemmed prosthesis. In such cases, corrective osteotomies are associated with poor results [31]. Reports of these types of special cases are limited to only rare single cases within the studies. Other advantages of the canal-sparing respectively stemless prosthesis are that it can preserve bone stock of the proximal humerus, as well as avoid humeral stem-related complications in revision cases requiring stem removal. In a commentary, Athwal summarized the advantages of the canal-sparing respectively stemless implant as a theoretically decreased surgical time, less blood loss, bone preservation, and lower risk of intraoperative and potentially postoperative periprosthetic fractures. Canal-sparing respectively stemless prostheses are also suitable for posttraumatic joint reconstruction and, when needed, explantation is easier compared to with the stemmed version. Following explantation, a stemless prosthesis can be replaced by a standard-length primary implant [29]. For the purpose of this review, we chose to include all available literature evaluating anatomic canal-sparing respectively stemless humeral components in shoulder arthroplasty. This review article refers to only implant designs with metaphyseal fixation, and excludes humeral head resurfacing. It is much easier to achieve glenoid exposure for glenoid component implantation using canal-sparing respectively stemless implants compared to with humeral head resurfacing [3, 20]. It must be noted that, all reviewed studies provide only short or midterm results, and include only a limited number of patients. Additionally, some studies were reported by the designer or co-developer of the investigated implant, which suggests the possibility of a certain bias. There are presently ongoing IDE trials, which will provide more robust and high-quality data on this topic.

Conclusions

All of the published studies describing anatomic canal-sparing respectively stemless shoulder replacement showed promising clinical and radiological outcomes over short to midterm follow-up periods. To date, the available literature lacks well-designed clinical studies with at least midterm results.
  28 in total

1.  Geometrical analysis of stemless shoulder arthroplasty: a radiological study of seventy TESS total shoulder prostheses.

Authors:  Bakir Kadum; Hamid Hassany; Mats Wadsten; Arkan Sayed-Noor; Göran Sjödén
Journal:  Int Orthop       Date:  2015-08-11       Impact factor: 3.075

2.  Complications of total shoulder arthroplasty: are they fewer or different?

Authors:  Patrick Y K Chin; John W Sperling; Robert H Cofield; Cathy Schleck
Journal:  J Shoulder Elbow Surg       Date:  2006 Jan-Feb       Impact factor: 3.019

3.  Midterm results of stemless shoulder arthroplasty: a prospective study.

Authors:  Peter Habermeyer; Sven Lichtenberg; Mark Tauber; Petra Magosch
Journal:  J Shoulder Elbow Surg       Date:  2015-04-11       Impact factor: 3.019

4.  Impact of prosthetic design on clinical and radiologic outcomes of total shoulder arthroplasty: a prospective study.

Authors:  Helen Razmjou; Richard Holtby; Monique Christakis; Terry Axelrod; Robin Richards
Journal:  J Shoulder Elbow Surg       Date:  2012-07-21       Impact factor: 3.019

Review 5.  Complications of total shoulder-replacement arthroplasty.

Authors:  M A Wirth; C A Rockwood
Journal:  J Bone Joint Surg Am       Date:  1996-04       Impact factor: 5.284

6.  Results of the Total Evolutive Shoulder System (TESS): a single-centre study of 56 consecutive patients.

Authors:  Bakir Kadum; Nader Mafi; Sigge Norberg; Arkan S Sayed-Noor
Journal:  Arch Orthop Trauma Surg       Date:  2011-08-07       Impact factor: 3.067

7.  Copeland surface replacement of the shoulder. Results of an hydroxyapatite-coated cementless implant in patients over 80 years of age.

Authors:  H Mullett; O Levy; D Raj; T Even; R Abraham; S A Copeland
Journal:  J Bone Joint Surg Br       Date:  2007-11

8.  Minimum fifteen-year follow-up of Neer hemiarthroplasty and total shoulder arthroplasty in patients aged fifty years or younger.

Authors:  John W Sperling; Robert H Cofield; Charles M Rowland
Journal:  J Shoulder Elbow Surg       Date:  2004 Nov-Dec       Impact factor: 3.019

9.  Outcome of Copeland shoulder resurfacing arthroplasty with a 4-year mean follow-up.

Authors:  Omid Alizadehkhaiyat; Alexandros Kyriakos; Mohamed S Singer; Simon P Frostick
Journal:  J Shoulder Elbow Surg       Date:  2013-04-04       Impact factor: 3.019

10.  Periprosthetic humeral fractures during shoulder arthroplasty.

Authors:  George S Athwal; John W Sperling; Damian M Rispoli; Robert H Cofield
Journal:  J Bone Joint Surg Am       Date:  2009-03-01       Impact factor: 5.284

View more
  16 in total

Review 1.  Short-term results of a new anatomic stemless shoulder arthroplasty - A prospective multicentre study.

Authors:  Tomas Smith; Hauke Horstmann; Roman Karkosch; Spiros Tsamassiotis; Nina Bowsher; Alexander Ellwein; Marc-Frederic Pastor
Journal:  Orthop Rev (Pavia)       Date:  2022-07-27

2.  Mid-term results of a stemless ceramic on polyethylene shoulder prosthesis - A prospective multicentre study.

Authors:  R W Jordan; C P Kelly; G Pap; T Joudet; R W Nyffeler; F Reuther; U Irlenbusch
Journal:  Shoulder Elbow       Date:  2019-08-14

3.  Restoration of the joint geometry and outcome after stemless TESS shoulder arthroplasty.

Authors:  Lars V von Engelhardt; Michael Manzke; Andreas Breil-Wirth; Timm J Filler; Joerg Jerosch
Journal:  World J Orthop       Date:  2017-10-18

4.  Cementless metaphyseal reverse shoulder arthroplasty: our preliminary experience.

Authors:  Gian Mario Micheloni; Gianpaolo Salmaso; Mattia Berti; Sara Bortolato; Gino Zecchinato; Alberto Momoli; Stefano Giaretta
Journal:  Acta Biomed       Date:  2019-01-10

5.  Total shoulder arthroplasty with nonspherical humeral head and inlay glenoid replacement: clinical results comparing concentric and nonconcentric glenoid stages in primary shoulder arthritis.

Authors:  Anthony C Egger; Jennifer Peterson; Morgan H Jones; Anthony Miniaci
Journal:  JSES Open Access       Date:  2019-09-13

Review 6.  Humeral bone grafting in stemless shoulder arthroplasty.

Authors:  Fabian Plachel; Markus Scheibel
Journal:  Obere Extrem       Date:  2017-08-03

7.  Primary Shoulder Hemiarthroplasty: What Can Be Learned From 359 Cases That Were Surgically Revised?

Authors:  Daniel J Hackett; Jason E Hsu; Frederick A Matsen
Journal:  Clin Orthop Relat Res       Date:  2018-05       Impact factor: 4.176

8.  Screw fixation in stemless shoulder arthroplasty for the treatment of primary osteoarthritis leads to less osteolysis when compared to impaction fixation.

Authors:  Arad Alikhah; Jan-Phillipp Imiolczyk; Anna Krukenberg; Markus Scheibel
Journal:  BMC Musculoskelet Disord       Date:  2020-05-12       Impact factor: 2.362

9.  Do the radiological changes seen at mid term follow up of stemless shoulder prosthesis affect outcome?

Authors:  Mohamed Moursy; Milan Niks; Aditya S Kadavkolan; Lars J Lehmann
Journal:  BMC Musculoskelet Disord       Date:  2019-10-27       Impact factor: 2.362

10.  The short- to midterm effectiveness of stemless prostheses compared to stemmed prostheses for patients who underwent total shoulder arthroplasty: a meta-analysis.

Authors:  Wei Peng; Yufu Ou; Chenglong Wang; Jianxun Wei; Xiaoping Mu; Zhian He
Journal:  J Orthop Surg Res       Date:  2019-12-30       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.