Tomas Smith1, Hauke Horstmann1, Roman Karkosch1, Spiros Tsamassiotis1, Nina Bowsher2, Alexander Ellwein3, Marc-Frederic Pastor1. 1. Department of orthopaedic surgery, Medical School Hannover, Anna-von-Borries Str. 1, 30625 Hannover, Germany. 2. DePuy Synthes, 700 Orthopaedic Drive,Warsaw, IN 46581, United States. 3. Department of orthopaedic and trauma surgery, Friederikensift Hannover, Humboldtstraße 5, 30169 Hannover, Germany.
Abstract
Background: Anatomic total shoulder arthroplasty (TSA) has been continuously developed and current designs include stemless or canal-sparing humeral components. In the literature stemless and canal sparing TSA showed good clinical and radiographic results, which were comparable to stemmed TSA. Objective: The aim of this study was to determine the short-term clinical and radiological outcomes of a new stemless TSA design. Methods: A prospective multicentre study including 154 total shoulder arthroplasty patients with a follow up of 12 months was performed. At the time of follow up 129 patients were available for review. The adjusted Constant Murley score,1 Oxford Shoulder Score, EQ-5D-5L score and radiographs were examined preoperatively, 3 and 12 months after the implantation of the new stemless TSA implant GLOBAL ICON™ (DePuy Synthes, Warsaw, IN, USA). Complications were documented. Results: Implant Kaplan-Meier survivorship was 98.7% at 12 months. From baseline to 12 months follow-up, all scores showed a progressive significant mean improvement. The mean adjusted Constant score increased from 42.3 to 96.1 points (p<0.001). The Oxford Shoulder Score showed an increase of 21.6 points (p<0.001). The postoperative radiographs showed no continuous radiolucent lines, subsidence, aseptic loosening or progressive radiolucency, but one osteolytic lesion was observed. Only 2 prostheses were revised. Conclusion: The new GLOBAL ICON stemless TSA showed good clinical and radiographic results at short-term follow up which were comparable to early results of other stemless TSA. Further studies with longer follow up are needed in the future.
Background: Anatomic total shoulder arthroplasty (TSA) has been continuously developed and current designs include stemless or canal-sparing humeral components. In the literature stemless and canal sparing TSA showed good clinical and radiographic results, which were comparable to stemmed TSA. Objective: The aim of this study was to determine the short-term clinical and radiological outcomes of a new stemless TSA design. Methods: A prospective multicentre study including 154 total shoulder arthroplasty patients with a follow up of 12 months was performed. At the time of follow up 129 patients were available for review. The adjusted Constant Murley score,1 Oxford Shoulder Score, EQ-5D-5L score and radiographs were examined preoperatively, 3 and 12 months after the implantation of the new stemless TSA implant GLOBAL ICON™ (DePuy Synthes, Warsaw, IN, USA). Complications were documented. Results: Implant Kaplan-Meier survivorship was 98.7% at 12 months. From baseline to 12 months follow-up, all scores showed a progressive significant mean improvement. The mean adjusted Constant score increased from 42.3 to 96.1 points (p<0.001). The Oxford Shoulder Score showed an increase of 21.6 points (p<0.001). The postoperative radiographs showed no continuous radiolucent lines, subsidence, aseptic loosening or progressive radiolucency, but one osteolytic lesion was observed. Only 2 prostheses were revised. Conclusion: The new GLOBAL ICON stemless TSA showed good clinical and radiographic results at short-term follow up which were comparable to early results of other stemless TSA. Further studies with longer follow up are needed in the future.
Entities:
Keywords:
Stemless; canal-sparing; osteoarthritis; total shoulder arthroplasty
Authors: Leonid I Katolik; Anthony A Romeo; Brian J Cole; Nikhil N Verma; Jennifer K Hayden; Bernard R Bach Journal: J Shoulder Elbow Surg Date: 2005 May-Jun Impact factor: 3.019
Authors: Florian Barvencik; Matthias Gebauer; Frank Timo Beil; Eik Vettorazzi; Marcus Mumme; Martin Rupprecht; Pia Pogoda; Karl Wegscheider; Johannes M Rueger; Klaus Pueschel; Michael Amling Journal: J Orthop Res Date: 2010-01 Impact factor: 3.494
Authors: Michael W Maier; Sarah Lauer; Matthias C Klotz; Matthias Bülhoff; David Spranz; Felix Zeifang Journal: BMC Musculoskelet Disord Date: 2015-10-01 Impact factor: 2.362