Geeta Shakya1, Dipendra Raman Singh2, Hemanta Chandra Ojha2, Chet Raj Ojha3, Shravan Kumar Mishra3, Karishma Malla4, Puspa Chaudhary4, Kiran Regmi5.
Abstract
BACKGROUND: Accurate and prompt diagnosis of HIV and syphilis simultaneously has reinforcing effect on their control program because of their prevalent co-infection. Availability of a simple user-friendly two-pronged and affordable detection tools brings down the cost of health care. They are important in the antenatal clinics, with added opportunity for intervention and prevention of mother to child transmission. In cooperation with rapid test kit manufacturers, SD Bioline, NPHL and NCASC, an evaluation of commercially available HIV/syphilis Duo rapid test kit (SD Bioline) to assess its performance and operational characteristics was done in the present study.Entities:
Keywords: Duo test; Kappa coefficient; Sensitivity; Specificity
Mesh:
Substances:
Year: 2016 PMID: 27566067 PMCID: PMC5002177 DOI: 10.1186/s12879-016-1694-9
Source DB: PubMed Journal: BMC Infect Dis ISSN: 1471-2334 Impact factor: 3.090
Sample size and sample characteristics (n = 10,000)
| Sample collection method: | Number of samples (%) |
|---|---|
| Venepuncture blood samples for serum collection | 9,453 (94.53 %) |
| Finger-prick whole blood samples | 547 (5.47 %) |
| Total number of samples collected by both methods | (9,453 + 547) = 10,000 |
Assay results of the SD BIOLINE HIV/syphilis Duo test for dual detection of HIV and syphilis, Kathmandu, Nepal, 2014
| RDT | Infection | RDT Result | Reference methoda | ||
|---|---|---|---|---|---|
| Positive | Negative | Total | |||
| Using SD Bioline HIV/Syphilis duo test kit | Syphilis | Positive | 42 | 13 | 55 |
| Negative | 2 | 9943 | 9945 | ||
| Total | 10,000 | ||||
| HIV | Positive | 19 | 0 | 19 | |
| Negative | 0 | 9981 | 9981 | ||
| Total | 10,000 | ||||
RDT rapid diagnostic test
aTested by using national HIV testing algorithm [7] with a combination of Determine HIV-1/2/O assay (Abbott Laboratories, Abbott Park, IL), Uni-Gold Recombinant HIV-1/2 (Trinity Biotech, Bray, Ireland) HIV 1/2 Stat-Pak Ultra Fast (Chembio Diagnostic Systems, Medford, NY). Testing for syphilis was done, first by RPR test by using IMMUTREP RPR test kit (Omega Diagnostics Scotland UK) and all test positive samples were re-confirmed by TPHA method. (Thirteen (0.13 %) cases in syphilis testing were found false positive while two were false negative and in case of HIV all of 19 cases tested positive using SD Bioline HIV/Syphilis duo test kit also tested positive by the reference method.)
Comparison of results of Southern Ethiopia and Kathmandu, Nepal studies
| RDT | Southern Ethiopia, 2014a | Kathmandu, Nepal, 2014b |
|---|---|---|
| SD HIV/syphilis Duo | Infection | |
| % Sensitivity 95 % CI | HIV 100 (98.5 to 100) | 100 % (95 % CI: 83.18–100 %) |
| Syphilis 97.6 (92.4 to 99.6) | 95.45 (95 % CI: 84.86–98.74 %) | |
| % Specificity % CI | HIV 99.5 (97.6 to 100) | 100 % (95 % CI: 99.96–100 %) |
| Syphilis 96 (90.6 to 98.7) | 99.87 (95 % CI: 99.78–99.92 %) | |
| % PPV 95 % CI | HIV 99.5 (97.6 to 100) | 100 % (95 % CI: 83.18–100 %) |
| Syphilis 95.4 (89.3 to 98.5) | 76.36 (95 % CI: 63.65–85.63 %) | |
| % NPV 95 % CI | HIV 100 (98.5 to 100) | 100 % (95 % CI: 99.96–100 %) |
| Syphilis 98 (93.4 to 99.7) | 99.89 (95 % CI; 99.39–99.99 %) |
aSyphilis reference method, TPHA; HIV reference method, KHB/STAT-PAK/Unigold algorithm + ELISA. KHB, Shenghai Kehua Bioengineering; NPV, negative predictive value; PPV, positive predictive value; RDT, rapid diagnostic test. Ref: [11]
bReference method: Tested by using national HIV testing algorithm [7] with a combination of Determine HIV-1/2/O assay (Abbott Laboratories, Abbott Park, IL), Uni-Gold Recombinant HIV-1/2 (Trinity Biotech, Bray, Ireland) HIV 1/2 Stat-Pak Ultra Fast (Chembio Diagnostic Systems, Medford, NY). Testing for syphilis was done, first by RPR test by using IMMUTREP RPR test kit (Omega Diagnostics Scotland UK)