Literature DB >> 27550911

Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study.

Edoardo Casiglia1, Valérie Tikhonoff2, Federica Albertini2, Paolo Palatini2.   

Abstract

The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; P<0.0001 for both); 621 subjects had home measurement error of at least ±5 mm Hg and 455 of at least ±10 mm Hg (bad measurers). In multivariable linear regression, a lower cognitive pattern independently determined both the systolic and the diastolic home measurement error and a longer forearm the systolic error only. This was confirmed by logistic regression having bad measurers as dependent variable. The use of wrist devices for home self-measurement, therefore, leads to frequent detection of falsely elevated blood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist.
© 2016 American Heart Association, Inc.

Entities:  

Keywords:  blood pressure; epidemiology; heart; methods; wrist

Mesh:

Year:  2016        PMID: 27550911     DOI: 10.1161/HYPERTENSIONAHA.116.07961

Source DB:  PubMed          Journal:  Hypertension        ISSN: 0194-911X            Impact factor:   10.190


  15 in total

1.  History and Justification of a National Blood Pressure Measurement Validated Device Listing.

Authors:  Jordana B Cohen; Raj S Padwal; Michael Gutkin; Beverly B Green; Michael J Bloch; F Wilford Germino; Domenic A Sica; Anthony J Viera; Benjamin M Bluml; William B White; Sandra J Taler; Steven Yarows; Daichi Shimbo; Raymond R Townsend
Journal:  Hypertension       Date:  2019-02       Impact factor: 10.190

Review 2.  The physical examination as a window into autonomic disorders.

Authors:  William P Cheshire; David S Goldstein
Journal:  Clin Auton Res       Date:  2018-01-02       Impact factor: 4.435

Review 3.  Point-of-care diagnostics to improve maternal and neonatal health in low-resource settings.

Authors:  Catherine E Majors; Chelsey A Smith; Mary E Natoli; Kathryn A Kundrod; Rebecca Richards-Kortum
Journal:  Lab Chip       Date:  2017-10-11       Impact factor: 6.799

4.  Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time.

Authors:  Venu G Ganti; Andrew M Carek; Brandi N Nevius; J Alex Heller; Mozziyar Etemadi; Omer T Inan
Journal:  IEEE J Biomed Health Inform       Date:  2021-06-03       Impact factor: 7.021

5.  The Need for Accurate Data on Blood Pressure Measurement in the Dental Office.

Authors:  Merrill F Elias; Amanda L Goodell
Journal:  Am J Hypertens       Date:  2020-04-01       Impact factor: 2.689

6.  Non-Targeted Self-Measurement of Blood Pressure: Association with Self-Medication, Unscheduled Emergency Visits and Anxiety.

Authors:  Glessiane de Oliveira Almeida; Felipe J Aidar; Dihogo Gama de Matos; Paulo Francisco de Almeida-Neto; Enaldo Vieira de Melo; José Augusto Soares Barreto Filho; Marcos Antonio Almeida-Santos; Victor Batista Oliveira; Rebeca Rocha de Almeida; Suelen Maiara Dos Santos; Larissa Monteiro Costa Pereira; Juliana Santos Barbosa; Antônio Carlos Sobral Sousa
Journal:  Medicina (Kaunas)       Date:  2021-01-17       Impact factor: 2.430

7.  Smartphone / smartwatch-based cuffless blood pressure measurement : a position paper from the Korean Society of Hypertension.

Authors:  Hae Young Lee; Dong-Ju Lee; Jongmo Seo; Sang-Hyun Ihm; Kwang-Il Kim; Eun Joo Cho; Hyeon Chang Kim; Jinho Shin; Sungha Park; Il-Suk Sohn; Wook-Jin Chung; Sung Kee Ryu; Ki Chul Sung; Juhan Kim; Dae-Hee Kim; Wook Bum Pyun
Journal:  Clin Hypertens       Date:  2021-01-25

8.  Education program for prevention of outdoor accidents in middle-high aged trekkers: Monitoring of change in blood pressure and heart rate during exercise.

Authors:  Rie Mieda; Yusuke Matsui; Masaru Tobe; Masafumi Kanamoto; Takashi Suto; Shigeru Saito
Journal:  Prev Med Rep       Date:  2021-05-13

9.  Hypertension in Cancer Patients and Survivors: Epidemiology, Diagnosis, and Management.

Authors:  Jordana B Cohen; Abdallah S Geara; Jonathan J Hogan; Raymond R Townsend
Journal:  JACC CardioOncol       Date:  2019-12-17

10.  Response to exercise-induced blood pressure elevation is blunted in wrist-cuff automated oscillometric measurement in healthy young college students.

Authors:  Tatsuya Sato; Nobutoshi Ichise; Yoshinori Terashima; Aoi Kato; Hiroya Yamazaki; Shunsuke Jimbo; Noritsugu Tohse
Journal:  Physiol Rep       Date:  2020-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.