INTRODUCTION: The LMA Supreme™, i-gel® and LMA ProSeal™ are second-generation supraglottic airway devices. We tested the hypothesis that these devices differ in performance when used for spontaneous ventilation during anaesthesia.
METHODS: 150 patients who underwent general anaesthesia for elective surgery were randomly allocated into three groups. Data was collected on oropharyngeal leak pressures, ease and duration of device insertion, ease of gastric tube insertion, and airway safety.
RESULTS: Leak pressure, our primary outcome measure, was found to be higher for the i-gel than the Supreme and ProSeal (mean ± standard error of the mean: 27.31 ± 0.92 cmH2O, 23.60 ± 0.70 cmH2O and 24.44 ± 0.70 cmH2O, respectively; p = 0.003). Devices were inserted on the first attempt for 90%, 82% and 72% of patients in the i-gel, Supreme and ProSeal groups, respectively (p = 0.105); mean device placement times were 23.58 seconds, 25.10 seconds and 26.34 seconds, respectively (p = 0.477). Gastric tubes were inserted on the first attempt in 100% of patients in the Supreme group, and 94% of patients in the i-gel and ProSeal groups (p = 0.100). There was blood staining on removal in 9 (18%) patients in each of the Supreme and ProSeal groups, with none in the i-gel group (p = 0.007). The incidence of postoperative sore throat, dysphagia and hoarseness was lowest for the i-gel.
CONCLUSION: The three devices were comparable in terms of ease and duration of placement, but the i-gel had higher initial oropharyngeal leak pressure and lower airway morbidity compared with the ProSeal and Supreme. Copyright: © Singapore Medical Association.

Entities:  

Keywords:  LMA; ProSeal; Supreme; airway; i-gel

Mesh:

Year:  2016        PMID: 27549212      PMCID: PMC4993967          DOI: 10.11622/smedj.2016133

Source DB:  PubMed          Journal:  Singapore Med J        ISSN: 0037-5675            Impact factor:   1.858


  25 in total

1.  LMA Supreme™ vs i-gel™--a comparison of insertion success in novices.

Authors:  R Ragazzi; L Finessi; I Farinelli; R Alvisi; C A Volta
Journal:  Anaesthesia       Date:  2012-02-13       Impact factor: 6.955

2.  Evaluation of the i-gel airway in 300 patients.

Authors:  O A Bamgbade; W R Macnab; W M Khalaf
Journal:  Eur J Anaesthesiol       Date:  2008-06-06       Impact factor: 4.330

3.  Safety and efficacy of laryngeal mask airway Supreme versus laryngeal mask airway ProSeal: a randomized controlled trial.

Authors:  Edwin Seet; Subramanyam Rajeev; Tamal Firoz; Farhanah Yousaf; Jean Wong; David T Wong; Frances Chung
Journal:  Eur J Anaesthesiol       Date:  2010-07       Impact factor: 4.330

4.  Regurgitation of gastric contents during general anaesthesia using the laryngeal mask airway.

Authors:  P Barker; J A Langton; P J Murphy; D J Rowbotham
Journal:  Br J Anaesth       Date:  1992-09       Impact factor: 9.166

5.  [A comparison of the single-use i-gel with the reusable laryngeal mask airway Proseal in anesthetized adult patients in Japanese population].

Authors:  Kentaro Hayashi; Akihiro Suzuki; Takayuki Kunisawa; Osamu Takahata; Yuzuru Yamasawa; Hiroshi Iwasaki
Journal:  Masui       Date:  2013-02

6.  [Comparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance].

Authors:  Reyhan Polat; Gözde Bumin Aydin; Jülide Ergil; Murat Sayin; Tuğba Kokulu; İbrahim Öztürk
Journal:  Rev Bras Anestesiol       Date:  2014-09-28       Impact factor: 0.964

7.  Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients.

Authors:  J J Gatward; T M Cook; C Seller; J Handel; T Simpson; V Vanek; F Kelly
Journal:  Anaesthesia       Date:  2008-07-09       Impact factor: 6.955

8.  Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy.

Authors:  Woo Jae Jeon; Sang Yun Cho; Seong Jin Baek; Kyoung Hun Kim
Journal:  Korean J Anesthesiol       Date:  2012-12-14

9.  Comparative study between I-gel, a new supraglottic airway device, and classical laryngeal mask airway in anesthetized spontaneously ventilated patients.

Authors:  Amr M Helmy; Hossam M Atef; Ezzat M El-Taher; Ahmed Mosaad Henidak
Journal:  Saudi J Anaesth       Date:  2010-09

10.  Comparison of clinical performance of the I-gel with LMA proseal.

Authors:  Gaurav Chauhan; Pavan Nayar; Anita Seth; Kapil Gupta; Mamta Panwar; Nidhi Agrawal
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01
View more
  10 in total

1.  A prospective randomised trial to compare three insertion techniques for i-gel™ placement: Standard, reverse, and rotation.

Authors:  Mamta Bhardwaj; Suresh K Singhal; Amit Dahiya
Journal:  Indian J Anaesth       Date:  2020-07-01

2.  Comparing I-Gel to Proseal Laryngeal Mask Airways in Infants: A Prospective Randomised Clinical Study.

Authors:  Sibel Oba; Hacer Şebnem Türk; Leyla Kılınç; Birsen Ekşioğlu Karacı; Serkan İslamoğlu
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-11-25

3.  Comparison between the Baska Mask® and I-Gel for Minor Surgical Procedures Under General Anaesthesia.

Authors:  Roopa Sachidananda; Safiya I Shaikh; Milon Vasant Mitragotri; Vikas Joshi; Dharmesh Arvind Ladhad; Marutheesh Mallappa; Vikram Kemmannu Bhat
Journal:  Turk J Anaesthesiol Reanim       Date:  2019-02-01

4.  A randomised controlled trial comparing ProSeal laryngeal mask airway, i-gel and Laryngeal Tube Suction-D under general anaesthesia for elective surgical patients requiring controlled ventilation.

Authors:  Bikramjit Das; Rahul Varshney; Subhro Mitra
Journal:  Indian J Anaesth       Date:  2017-12

5.  A comparative evaluation of ProSeal laryngeal mask airway, I-gel and Supreme laryngeal mask airway in adult patients undergoing elective surgery: A randomised trial.

Authors:  Anisha Singh; Anju R Bhalotra; Raktima Anand
Journal:  Indian J Anaesth       Date:  2018-11

6.  Comprehensive evaluation of manikin-based airway training with second generation supraglottic airway devices.

Authors:  Axel Schmutz; Erich Bohn; Johannes Spaeth; Sebastian Heinrich
Journal:  Ther Clin Risk Manag       Date:  2019-03-01       Impact factor: 2.423

7.  Comparison of new generation baska mask with i-gel and classical laryngeal mask in outpatient urological interventions.

Authors:  Mustafa Bindal; Asli Demir; Rabia Koculu; Ulku Sabuncu; Aysegul Ozgok
Journal:  Saudi Med J       Date:  2019-07       Impact factor: 1.484

8.  Comparison of Two Supraglottic Airway Devices: I-gel Airway and ProSeal Laryngeal Mask Airway Following Digital Insertion in Nonparalyzed Anesthetized Patients.

Authors:  Ankur Luthra; Rajeev Chauhan; Amit Jain; Ishwar Bhukal; Shalvi Mahajan; Indu Bala
Journal:  Anesth Essays Res       Date:  2019-12-16

9.  Comparative evaluation of i-gel® insertion conditions using dexmedetomidine-propofol versus fentanyl-propofol - A randomised double-blind study.

Authors:  Preeti Sachin Rustagi; Shalaka Sandeep Nellore; Amala Guru Kudalkar; Rashmi Sawant
Journal:  Indian J Anaesth       Date:  2019-11-08

10.  A cohort evaluation of clinical use and performance characteristics of Ambu® AuraGain™: A prospective observational study.

Authors:  Devangi A Parikh; Ruchi A Jain; Smita S Lele; Bharati A Tendolkar
Journal:  Indian J Anaesth       Date:  2017-08
  10 in total