Literature DB >> 18616521

Evaluation of the size 4 i-gel airway in one hundred non-paralysed patients.

J J Gatward1, T M Cook, C Seller, J Handel, T Simpson, V Vanek, F Kelly.   

Abstract

We studied the i-gel in 100 elective, anaesthetised patients (55:45 male:female, median age 53 years) assessing: ease of use, airway quality, positioning, seal and complications. First insertion attempt was successful in 86 patients, second attempt in 11 patients, and third attempt in three patients. Fifty three manipulations were required in 26 patients (median 1) to achieve a clear airway. Median insertion time was 15 s. During ventilation, expired tidal volume of 7 ml x kg(-1) was achieved in 96 (96%) patients. Median airway leak pressure was 24 cmH(2)O. On fibreoptic examination via the device, vocal cords were visible in 87 patients (91%). During maintenance, six patients (6%) required 12 airway manipulations. There was one episode of regurgitation, without aspiration. Other complications and patient side-effects were mild and few. The i-gel is easily and rapidly inserted, providing a reliable airway in over 90% of cases. Further studies are indicated to assess safety and performance compared to other supraglottic airway devices.

Entities:  

Mesh:

Year:  2008        PMID: 18616521     DOI: 10.1111/j.1365-2044.2008.05561.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  38 in total

Review 1.  [Extraglottic airway devices in the intensive care unit].

Authors:  S G Russo; O Moerer; E A Nickel; B Goetze; A Timmermann; M Quintel
Journal:  Anaesthesist       Date:  2010-06       Impact factor: 1.041

2.  Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery.

Authors:  Geoffrey Haw Chieh Liew; Esther Dawen Yu; Shitalkumar Sharad Shah; Harikrishnan Kothandan
Journal:  Singapore Med J       Date:  2016-08       Impact factor: 1.858

3.  Comparison of I-gel with Classic Laryngeal Mask Airway Regarding the Ease of Use and Clinical Performance.

Authors:  Dilek Erdoğan Arı; Arzu Yıldırım Ar; Ceren Şanlı Karip; İncifer Siyahkoç; Ahmet Hakan Arslan; Fatma Nur Akgün
Journal:  Turk J Anaesthesiol Reanim       Date:  2015-08-21

4.  [Evaluation of the new supraglottic airway devices Ambu AuraOnce and Intersurgical i-gel. Positioning, sealing, patient comfort and airway morbidity].

Authors:  J F Heuer; M Stiller; J Rathgeber; C Eich; K Züchner; M Bauer; A Timmermann
Journal:  Anaesthesist       Date:  2009-08       Impact factor: 1.041

5.  Randomized comparison of the i-gel(TM) with the LMA Supreme (TM) in anesthetized adult patients.

Authors:  J M Beleña; M Núñez; A Vidal; C Gasco; A Alcojor; P Lee; J L Pérez
Journal:  Anaesthesist       Date:  2015-03-24       Impact factor: 1.041

6.  Clinical Comparison of I-Gel Supraglottic Airway Device and Cuffed Endotracheal Tube for Pressure-Controlled Ventilation During Routine Surgical Procedures.

Authors:  Ankur Dhanda; Shalendra Singh; Anju R Bhalotra; Siddharth Chavali
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-10-01

7.  Effects of neuromuscular blocking agents on the clinical performance of i-gel® and surgical condition in elderly patients undergoing hand surgery: a prospective randomized controlled trial.

Authors:  Choon-Kyu Cho; Minhye Change; Seok-Jin Lee; Tae-Yun Sung
Journal:  Int J Med Sci       Date:  2021-04-16       Impact factor: 3.738

8.  Randomized comparison of the i-gel™, the LMA Supreme™, and the Laryngeal Tube Suction-D using clinical and fibreoptic assessments in elective patients.

Authors:  Sebastian G Russo; Stephan Cremer; Tamara Galli; Christoph Eich; Anselm Bräuer; Thomas A Crozier; Martin Bauer; Micha Strack
Journal:  BMC Anesthesiol       Date:  2012-08-07       Impact factor: 2.217

9.  Assessment of Success and Ease of Insertion of ProSeal™ Laryngeal Mask Airway versus I-gel™ Insertion by Paramedics in Simulated Difficult Airway Using Cervical Collar in Different Positions in Manikins.

Authors:  Arushi Gupta; Ankita Kabi; Divya Gaur
Journal:  Anesth Essays Res       Date:  2021-05-06

10.  Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients.

Authors:  Jeevan Singh; Manohar Kumar Yadav; Sujan Babu Marahatta; Bikash Lal Shrestha
Journal:  Indian J Anaesth       Date:  2012-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.