Literature DB >> 26363690

[Comparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance].

Reyhan Polat1, Gözde Bumin Aydin2, Jülide Ergil2, Murat Sayin2, Tuğba Kokulu2, İbrahim Öztürk2.   

Abstract

PURPOSE: The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance.
METHODS: We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation.
RESULTS: There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p=0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6±2.4s versus 13.1±1.8s [p=0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p=0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24h after the procedure (p=0.752).
CONCLUSION: Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

Entities:  

Keywords:  Dispositivos supraglóticos; Laryngeal Mask Airway Classic; Máscara laríngea clássica; Supraglottic airway devices; i‐gel

Year:  2014        PMID: 26363690     DOI: 10.1016/j.bjan.2014.02.009

Source DB:  PubMed          Journal:  Rev Bras Anestesiol        ISSN: 0034-7094            Impact factor:   0.964


  4 in total

1.  Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery.

Authors:  Geoffrey Haw Chieh Liew; Esther Dawen Yu; Shitalkumar Sharad Shah; Harikrishnan Kothandan
Journal:  Singapore Med J       Date:  2016-08       Impact factor: 1.858

2.  Supraglottic Airway Devices for Elective Pediatric Anesthesia: I-gel versus Air-Q, Which is the Best?

Authors:  Rami Mounir Wahba; Milad Zekry Ragaei; Ayman Anis Metry; George Mikhael Nakhla
Journal:  Anesth Essays Res       Date:  2021-03-22

3.  I-Gel versus laryngeal mask airway (LMA) classic as a conduit for tracheal intubation using ventilating bougie.

Authors:  Aditi A Dhimar; Bhavika R Sangada; Mahendra R Upadhyay; Sangita H Patel
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Oct-Dec

4.  Application of lower limb nerve block combined with slow induction of light general anesthesia and tracheal induction in elderly hip surgery.

Authors:  Zheng-Yuan Shi; Chun-Nan Jiang; Gang Shao
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817