The hemodynamic benefit of differential atrioventricular delay intervals for sensed and paced atrial events during physiologic pacing.

D L Janosik1, A C Pearson, T A Buckingham, A J Labovitz, R M Redd.   

Abstract

The ability to program different atrioventricular (AV) delay intervals for paced and sensed atrial events is incorporated in the design of some newer dual chamber pacemakers. However, little is known regarding the hemodynamic benefit of differential AV delay intervals or the magnitude of difference between optimal AV delay intervals for paced and sensed P waves in individual patients. In this study, Doppler-derived cardiac output was used to examine the optimal timing of paced and sensed atrial events in 24 patients with a permanent dual chamber pacemaker. The hemodynamic effect of utilizing separate optimal delay intervals for sensed and paced events compared with utilizing the same fixed AV delay interval for both was determined. The optimal delay interval during DVI (AV sequential) pacing and VDD (atrial triggered, ventricular inhibited) pacing at similar heart rates was 176 +/- 44 and 144 +/- 48 ms (p less than 0.002), respectively. The mean difference between the optimal AV delay intervals for sensed (VDD) and paced (DVI) P waves was 32 ms and was up to 100 ms in some individuals. The difference between optimal AV delay intervals for sensed and paced atrial events was similar in patients with complete heart block and those with intact AV node conduction. At the respective optimal AV delay intervals for sensed and paced P waves, there was no significant difference in the cardiac output during VDD compared with DVI pacing. However, cardiac output significant declined during VDD pacing at the optimal AV delay interval for a paced event and during DVI pacing at the optimal interval for a sensed event.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2754135     DOI: 10.1016/0735-1097(89)90208-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  Comparison of echocardiography and device based algorithm for atrio-ventricular delay optimization in heart block patients.

Authors:  Rajesh Vijayvergiya; Ankur Gupta
Journal:  World J Cardiol       Date:  2015-11-26

2.  [Optimized CRT programming: relevance and practical application].

Authors:  F Bode; F Schütte
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-09

3.  Difference in mechanical atrioventricular delay between atrial sensing and atrial pacing modes in patients with hypertrophic and dilated cardiomyopathy: an electrical hemodynamic catheterization study.

Authors:  Yong-Mei Cha; Rick A Nishimura; David L Hayes
Journal:  J Interv Card Electrophysiol       Date:  2002-06       Impact factor: 1.900

Review 4.  Strategies for pacemaker programming in acute heart failure.

Authors:  Marc K Lahiri; Justin T Mao; Claudio D Schuger
Journal:  Heart Fail Rev       Date:  2011-09       Impact factor: 4.214

5.  Reduction of right ventricular pacing in patients with sinus node dysfunction through programming a long atrioventricular delay along with the DDIR mode.

Authors:  Aischa Nitardy; Holger Langreck; Rainer Dietz; Martin Stockburger
Journal:  Clin Res Cardiol       Date:  2008-10-13       Impact factor: 5.460

6.  DDD pacing in hypertrophic cardiomyopathy: a multicentre clinical experience.

Authors:  A K Slade; N Sadoul; L Shapiro; L Chojnowska; J P Simon; R C Saumarez; B Dodinot; A J Camm; W J McKenna; E Aliot
Journal:  Heart       Date:  1996-01       Impact factor: 5.994

7.  Influence of atrioventricular optimization on hemodynamic parameters and quality of life in patients with dual chamber pacemaker with ventricular lead in right ventricular outflow tract.

Authors:  Artur Klimczak; Adam S Budzikowski; Marcin Rosiak; Marzenna Zielińska; Bożena Urbanek; Karol Bartczak; Michał Chudzik; Jerzy K Wranicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-03-06       Impact factor: 1.468

8.  Echocardiographic AV-interval optimization in patients with reduced left ventricular function.

Authors:  C Melzer; A C Borges; F Knebel; W S Richter; W Combs; G Baumann; H Theres
Journal:  Cardiovasc Ultrasound       Date:  2004-12-17       Impact factor: 2.062

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.