Literature DB >> 27519441

Quantitative analysis of lipid classes by liquid chromatography via a flame ionization detector.

F C Phillips1, W L Erdahl1, O S Privett1.   

Abstract

A method is described for the direct quantitative analysis of the lipid classes of mammalian tissue lipids using high performance liquid chromatography (HPLC) with a flame ionization detector (FID). The lipid is extracted from the tissue with chloroform/methanol after deactivation of hydrolytic enzymes and removal of nonlipid substances by extraction with hot dilute acetic acid (0.05N). Separation of the lipid classes is performed with a column (45 cm × 0.2 cm id) of 8 μm silica (Spherisorb, Phase Sep, Hauppague, NY) treated with concentrated ammonium hydroxide at a solvent flow rate of 0.5 ml/min, which requires a pressure of ca. 900 psi. Cholesteryl esters (CE) and triglycerides (TG) are eluted first with Skellysolve B/methylene chloride (1∶1, v/v); cholesterol (CH) is eluted with chloroform/methylene chloride (1∶2, v/v) and the phospholipids with methanol containing 6% ammonium hydroxide added to the latter solvent in a linear gradient. The neutral lipids are eluted in ca. 12 min and the phospholipids in an additional 30 min. The relative amount of each lipid class was determined from standard curves of the peak areas obtained according to response factors using erucyl alcohol as an internal standard. The method was applied to samples of kidney, liver and serum of rats. Duplicate analyses were generally within ca. 1.0% and good agreement was obtained in the analysis of the lipid classes of Azolectin and liver mitochondria lipid compared to thin layer chromatography (TLC) via photodensitometry of charred spots or phosphorus analysis of recovered phospholipids.

Entities:  

Year:  1982        PMID: 27519441     DOI: 10.1007/BF02534597

Source DB:  PubMed          Journal:  Lipids        ISSN: 0024-4201            Impact factor:   1.880


  15 in total

1.  Phosphorus assay in column chromatography.

Authors:  G R BARTLETT
Journal:  J Biol Chem       Date:  1959-03       Impact factor: 5.157

2.  A vapour dilution system for detector calibration.

Authors:  I A FOWLIS; R P SCOTT
Journal:  J Chromatogr       Date:  1963-05

3.  High-performance liquid chromatography of phosphatidylcholine and sphingomyelin with detection in the region of 200 nm.

Authors:  F B Jungalwala; J E Evans; R H McCluer
Journal:  Biochem J       Date:  1976-04-01       Impact factor: 3.857

4.  Analysis of soybean lecithin by thin layer and analytical liquid chromatography.

Authors:  W L Erdahl; A Stolyhwo; O S Privett
Journal:  J Am Oil Chem Soc       Date:  1973-12       Impact factor: 1.849

5.  Studies on the lipid composition of developing soybeans.

Authors:  O S Privett; K A Dougherty; W L Erdahl; A Stolyhwo
Journal:  J Am Oil Chem Soc       Date:  1973-12       Impact factor: 1.849

6.  Two dimensional then layer chromatographic separation of polar lipids and determination of phospholipids by phosphorus analysis of spots.

Authors:  G Rouser; S Fkeischer; A Yamamoto
Journal:  Lipids       Date:  1970-05       Impact factor: 1.880

7.  A simplified procedure for the quantitative extraction of lipids from brain tissue.

Authors:  F Phillips; O S Privett
Journal:  Lipids       Date:  1979-06       Impact factor: 1.880

8.  High-performance liquid chromatographic separations of phospholipids and phospholipid oxidation products.

Authors:  N A Porter; H Weenen
Journal:  Methods Enzymol       Date:  1981       Impact factor: 1.600

9.  Separation of phospholipids and individual molecular species of phospholipids by high-performance liquid chromatography.

Authors:  G M Patton; J M Fasulo; S J Robins
Journal:  J Lipid Res       Date:  1982-01       Impact factor: 5.922

10.  High performance liquid chromatographic separation and direct ultraviolet detection of phospholipids.

Authors:  W S Van Kessel; W M Hax; R A Demel; J De Gier
Journal:  Biochim Biophys Acta       Date:  1977-03-25
View more
  3 in total

1.  Separation and quantification of heart and liver phospholipid classes by high-performance liquid chromatography using a new light-scattering detector.

Authors:  P Juanéda; G Rocquelin; P O Astorg
Journal:  Lipids       Date:  1990-11       Impact factor: 1.880

2.  Analysis of triglyceride species by high-performance liquid chromatography via a flame lonization detector.

Authors:  F C Phillips; W L Erdahl; J D Nadenicek; L J Nutter; J A Schmit; O S Privett
Journal:  Lipids       Date:  1984-02       Impact factor: 1.880

3.  Quantitative high-performance liquid chromatography analysis of plant phospholipids and glycolipids using light-scattering detection.

Authors:  G A Picchioni; A E Watada; B D Whitaker
Journal:  Lipids       Date:  1996-02       Impact factor: 1.880

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.