Literature DB >> 22230150

Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational simulations.

Nicolas Foin1, Ryo Torii, Peter Mortier, Mathieu De Beule, Nicola Viceconte, Pak Hei Chan, Justin E Davies, Xiao Yun Xu, Rob Krams, Carlo Di Mario.   

Abstract

OBJECTIVES: This study sought to evaluate post-dilation strategies in bifurcation stenting.
BACKGROUND: In bifurcation stenting practice, it is still controversial how post-dilation should be performed and whether the kissing balloon (KB) technique is mandatory when only the main vessel (MV) receives a stent.
METHODS: A series of drug-eluting stents (DES) (n = 26) were deployed in a coronary bifurcation model following a provisional approach. After the deployment of the stent in the MV, post-dilation with the KB technique was compared with a 2-step, sequential post-dilation of the side branch (SB) and MV without kissing.
RESULTS: The percentage of the SB lumen area free of stent struts was similar after KB (79.1 ± 8.7%) and after the 2-step sequence (74.4 ± 11.6%, p = 0.25), a considerable improvement compared with MV stenting only without dilation of the stent at the SB ostium (30.8 ± 7.8%, p < 0.0001). The rate of strut malapposition in the ostium was 21.3 ± 9.2% after KB and 24.9 ± 10.4% after the 2-step sequence, respectively, a significant reduction compared with a simple SB dilation (55.3 ± 16.8%, p < 0.0001) or MV stenting only (47.0 ± 8.5%, p < 0.0005). KB created a significant elliptical overexpansion of the MV lumen, inducing higher stress concentration proximal to the SB. KB also led to a higher risk of incomplete stent apposition at the proximal stent edge (30.7 ± 26.4% vs. 2.8 ± 9.6% for 2-step, p = 0.0016).
CONCLUSIONS: Sequential 2-step post-dilation of the SB and MV may offer a simpler and more efficient alternative to final KB technique for provisional stenting of bifurcations.
Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22230150     DOI: 10.1016/j.jcin.2011.08.019

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  19 in total

Review 1.  Update on Provisional Technique for Bifurcation Interventions.

Authors:  Lazzaro Paraggio; Francesco Burzotta; Cristina Aurigemma; Carlo Trani
Journal:  Curr Cardiol Rep       Date:  2016-03       Impact factor: 2.931

2.  Computational fluid dynamic simulations of image-based stented coronary bifurcation models.

Authors:  Claudio Chiastra; Stefano Morlacchi; Diego Gallo; Umberto Morbiducci; Rubén Cárdenes; Ignacio Larrabide; Francesco Migliavacca
Journal:  J R Soc Interface       Date:  2013-05-15       Impact factor: 4.118

3.  Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT.

Authors:  Hye-Joung Eom; Dong Hyun Yang; Young-Hak Kim; Jae-Hyung Roh; Jihoon Kweon; Soo-Jin Kang; Namkug Kim; Joon-Won Kang; Tae-Hwan Lim
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-09       Impact factor: 2.357

4.  Final kissing balloon inflation for coronary bifurcation lesions treated with single-stent technique : A meta-analysis.

Authors:  G Liu; X Ke; Z-B Huang; L-C Wang; Z-N Huang; Y Guo; M Long; X-X Liao
Journal:  Herz       Date:  2017-11-27       Impact factor: 1.443

5.  The Proximal Optimisation Technique for Intervention of Coronary Bifurcations.

Authors:  Angela Hoye
Journal:  Interv Cardiol       Date:  2017-09

6.  Practice Patterns in the Interventional Treatment of Coronary Bifurcation Lesions: A Global Survey.

Authors:  Ilias Nikolakopoulos; Evangelia Vemmou; Judit Karacsonyi; Lorenzo Azzalini; Brian A Bergmark; Yiannis S Chatzizisis; Allison B Hall; Jason Wollmuth; Kevin Croce; Hani Jneid; Bavana V Rangan; M Nicholas Burke; Emmanouil S Brilakis
Journal:  J Invasive Cardiol       Date:  2022-01       Impact factor: 2.022

7.  Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

Authors:  Yoshiyasu Minami; Zhao Wang; Aaron D Aguirre; Stephen Lee; Shiro Uemura; Tsunenari Soeda; Rocco Vergallo; Owen C Raffel; Peter Barlis; Tomonori Itoh; Hang Lee; James Fujimoto; Ik-Kyung Jang
Journal:  Coron Artery Dis       Date:  2016-01       Impact factor: 1.439

8.  Randomized Comparison of the Crush Versus the Culotte Stenting for Coronary Artery Bifurcation Lesions.

Authors:  Xu-Wei Zheng; Dong-Hui Zhao; Hong-Yu Peng; Qian Fan; Qin Ma; Zhen-Ye Xu; Chao Fan; Li-Yu Liu; Jing-Hua Liu
Journal:  Chin Med J (Engl)       Date:  2016-03-05       Impact factor: 2.628

9.  Comparative Computed Flow Dynamic Analysis of Different Optimization Techniques in Left Main Either Provisional or Culotte Stenting.

Authors:  Gianluca Rigatelli; Fabio Dell'Avvocata; Marco Zuin; Sara Giatti; Khanh Duong; Trung Pham; Nguyen Si Tuan; Dobrin Vassiliev; Ramesh Daggubati; Thach Nguyen
Journal:  J Transl Int Med       Date:  2017-12-29

10.  A Novel Tram Stent Method in the Treatment of Coronary Bifurcation Lesions - Finite Element Study.

Authors:  Mark C Arokiaraj; Gianluca De Santis; Matthieu De Beule; Igor F Palacios
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.