Literature DB >> 27502047

Calibrated bold fMRI with an optimized ASL-BOLD dual-acquisition sequence.

María A Fernández-Seara1, Zachary B Rodgers2, Erin K Englund2, Felix W Wehrli2.   

Abstract

Calibrated fMRI techniques estimate task-induced changes in the cerebral metabolic rate of oxygen (CMRO2) based on simultaneous measurements of cerebral blood flow (CBF) and blood-oxygen-level-dependent (BOLD) signal changes evoked by stimulation. To determine the calibration factor M (corresponding to the maximum possible BOLD signal increase), BOLD signal and CBF are measured in response to a gas breathing challenge (usually CO2 or O2). Here we describe an ASL dual-acquisition sequence that combines a background-suppressed 3D-GRASE readout with 2D multi-slice EPI. The concatenation of these two imaging sequences allowed separate optimization of the acquisition for CBF and BOLD data. The dual-acquisition sequence was validated by comparison to an ASL sequence with a dual-echo EPI readout, using a visual fMRI paradigm. Results showed a 3-fold increase in temporal signal-to-noise ratio (tSNR) of the ASL time-series data while BOLD tSNR was similar to that obtained with the dual-echo sequence. The longer TR of the proposed dual-acquisition sequence, however, resulted in slightly lower T-scores (by 30%) in the BOLD activation maps. Further, the potential of the dual-acquisition sequence for M-mapping on the basis of a hypercapnia gas breathing challenge and for quantification of CMRO2 changes in response to a motor activation task was assessed. In five subjects, an average gray matter M-value of 8.71±1.03 and fractional changes of CMRO2 of 12.5±5% were found. The new sequence remedies the deficiencies of prior combined BOLD-ASL acquisition strategies by substantially enhancing perfusion tSNR, which is essential for accurate BOLD calibration.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  3D GRASE; Arterial spin labeling; Background suppression; CMRO(2) quantification; Calibrated BOLD; Dual-echo EPI

Mesh:

Substances:

Year:  2016        PMID: 27502047      PMCID: PMC5159288          DOI: 10.1016/j.neuroimage.2016.08.007

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  32 in total

1.  Changes of cerebral blood flow, oxygenation, and oxidative metabolism during graded motor activation.

Authors:  Andreas Kastrup; Gunnar Krüger; Tobias Neumann-Haefelin; Gary H Glover; Michael E Moseley
Journal:  Neuroimage       Date:  2002-01       Impact factor: 6.556

2.  Analysis and design of perfusion-based event-related fMRI experiments.

Authors:  Thomas T Liu; Eric C Wong; Lawrence R Frank; Richard B Buxton
Journal:  Neuroimage       Date:  2002-05       Impact factor: 6.556

3.  On the application of ultra-fast RARE experiments.

Authors:  D G Norris; P Börnert; T Reese; D Leibfritz
Journal:  Magn Reson Med       Date:  1992-09       Impact factor: 4.668

4.  Phase insensitive preparation of single-shot RARE: application to diffusion imaging in humans.

Authors:  D C Alsop
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

5.  Noise reduction in multi-slice arterial spin tagging imaging.

Authors:  K S St Lawrence; J A Frank; P A Bandettini; F Q Ye
Journal:  Magn Reson Med       Date:  2005-03       Impact factor: 4.668

6.  Continuous arterial spin labeling perfusion measurements using single shot 3D GRASE at 3 T.

Authors:  María A Fernández-Seara; Ze Wang; Jiongjiong Wang; Heng-Yi Rao; Matthias Guenther; David A Feinberg; John A Detre
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

7.  Improving lesion-symptom mapping.

Authors:  Chris Rorden; Hans-Otto Karnath; Leonardo Bonilha
Journal:  J Cogn Neurosci       Date:  2007-07       Impact factor: 3.225

8.  Rapid magnetic resonance measurement of global cerebral metabolic rate of oxygen consumption in humans during rest and hypercapnia.

Authors:  Varsha Jain; Michael C Langham; Thomas F Floyd; Gaurav Jain; Jeremy F Magland; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-20       Impact factor: 6.200

9.  Minimizing acquisition time of arterial spin labeling at 3T.

Authors:  María A Fernández-Seara; Brian L Edlow; Angela Hoang; Jiongjiong Wang; David A Feinberg; John A Detre
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

10.  Quantitative measurement of cerebral physiology using respiratory-calibrated MRI.

Authors:  D P Bulte; M Kelly; M Germuska; J Xie; M A Chappell; T W Okell; M G Bright; P Jezzard
Journal:  Neuroimage       Date:  2011-12-22       Impact factor: 6.556

View more
  4 in total

1.  Calibrated fMRI for dynamic mapping of CMRO2 responses using MR-based measurements of whole-brain venous oxygen saturation.

Authors:  Erin K Englund; Maria A Fernández-Seara; Ana E Rodríguez-Soto; Hyunyeol Lee; Zachary B Rodgers; Marta Vidorreta; John A Detre; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2019-08-08       Impact factor: 6.200

Review 2.  Cerebral oxygen extraction fraction MRI: Techniques and applications.

Authors:  Dengrong Jiang; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2022-05-05       Impact factor: 3.737

3.  Cardiorespiratory noise correction improves the ASL signal.

Authors:  Mahlega S Hassanpour; Qingfei Luo; W Kyle Simmons; Justin S Feinstein; Martin P Paulus; Wen-Ming Luh; Jerzy Bodurka; Sahib S Khalsa
Journal:  Hum Brain Mapp       Date:  2018-02-15       Impact factor: 5.038

4.  The effect of acquisition duration on cerebral blood flow-based resting-state functional connectivity.

Authors:  Yuko Nakamura; Akiko Uematsu; Kazuo Okanoya; Shinsuke Koike
Journal:  Hum Brain Mapp       Date:  2022-03-26       Impact factor: 5.399

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.