Literature DB >> 27493981

Subject-specific four-dimensional liver motion modeling based on registration of dynamic MRI.

Yolanda H Noorda1, Lambertus W Bartels1, Max A Viergever1, Josien P W Pluim1.   

Abstract

Magnetic resonance-guided high intensity focused ultrasound treatment of the liver is a promising noninvasive technique for ablation of liver lesions. For the technique to be used in clinical practice, however, the issue of liver motion needs to be addressed. A subject-specific four-dimensional liver motion model is presented that is created based on registration of dynamically acquired magnetic resonance data. This model can be used for predicting the tumor motion trajectory for treatment planning and to indicate the tumor position for treatment guidance. The performance of the model was evaluated on a dynamic scan series that was not used to build the model. The method achieved an average Dice coefficient of 0.93 between the predicted and actual liver profiles and an average vessel misalignment of 3.0 mm. The model performed robustly, with a small variation in the results per subject. The results demonstrate the potential of the model to be used for MRI-guided treatment of liver lesions. Furthermore, the model can possibly be applied in other image-guided therapies, for instance radiotherapy of the liver.

Entities:  

Keywords:  dynamic data; liver motion model; magnetic resonance imaging; registration

Year:  2016        PMID: 27493981      PMCID: PMC4961895          DOI: 10.1117/1.JMI.3.1.015002

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  33 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images.

Authors:  Torsten Rohlfing; Calvin R Maurer; Walter G O'Dell; Jianhui Zhong
Journal:  Med Phys       Date:  2004-03       Impact factor: 4.071

3.  Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.

Authors:  Baudouin Denis de Senneville; Charles Mougenot; Chrit T W Moonen
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

Review 4.  Imaging and alignment for image-guided radiation therapy.

Authors:  James M Balter; Marc L Kessler
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

Review 5.  Advances in image-guided radiation therapy.

Authors:  Laura A Dawson; David A Jaffray
Journal:  J Clin Oncol       Date:  2007-03-10       Impact factor: 44.544

6.  Assessing residual motion for gated proton-beam radiotherapy.

Authors:  Gregory C Sharp; Hsiao Ming Lu; Alexei Trofimov; Xiaoli Tang; Steve B Jiang; Julie Turcotte; David P Gierga; George T Y Chen; Theodore S Hong
Journal:  J Radiat Res       Date:  2007       Impact factor: 2.724

7.  Systematic errors in respiratory gating due to intrafraction deformations of the liver.

Authors:  Martin von Siebenthal; Gábor Székely; Antony J Lomax; Philippe C Cattin
Journal:  Med Phys       Date:  2007-09       Impact factor: 4.071

8.  Primary pain palliation and local tumor control in bone metastases treated with magnetic resonance-guided focused ultrasound.

Authors:  Alessandro Napoli; Michele Anzidei; Beatrice Cavallo Marincola; Giulia Brachetti; Federica Ciolina; Gaia Cartocci; Claudia Marsecano; Fulvio Zaccagna; Luca Marchetti; Enrico Cortesi; Carlo Catalano
Journal:  Invest Radiol       Date:  2013-06       Impact factor: 6.016

9.  Model-guided respiratory organ motion prediction of the liver from 2D ultrasound.

Authors:  Frank Preiswerk; Valeria De Luca; Patrik Arnold; Zarko Celicanin; Lorena Petrusca; Christine Tanner; Oliver Bieri; Rares Salomir; Philippe C Cattin
Journal:  Med Image Anal       Date:  2014-04-13       Impact factor: 8.545

10.  Feasibility of volumetric MRI-guided high intensity focused ultrasound (MR-HIFU) for painful bone metastases.

Authors:  Merel Huisman; Mie K Lam; Lambertus W Bartels; Robbert J Nijenhuis; Chrit T Moonen; Floor M Knuttel; Helena M Verkooijen; Marco van Vulpen; Maurice A van den Bosch
Journal:  J Ther Ultrasound       Date:  2014-10-10
View more
  5 in total

1.  Deformable image registration for tissues with large displacements.

Authors:  Xishi Huang; Jing Ren; Anwar Abdalbari; Mark Green
Journal:  J Med Imaging (Bellingham)       Date:  2017-01-25

2.  Respiratory motion correction for free-breathing 3D abdominal MRI using CNN-based image registration: a feasibility study.

Authors:  Jun Lv; Ming Yang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-01-31       Impact factor: 3.039

3.  Image registration assessment in radiotherapy image guidance based on control chart monitoring.

Authors:  Wenyao Xia; Stephen L Breen
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-14

4.  Simulated accuracy assessment of small footprint body-mounted probe alignment device for MRI-guided cryotherapy of abdominal lesions.

Authors:  Naoyuki Shono; Brian Ninni; Franklin King; Takahisa Kato; Junichi Tokuda; Takahiro Fujimoto; Kemal Tuncali; Nobuhiko Hata
Journal:  Med Phys       Date:  2020-03-28       Impact factor: 4.071

5.  Motion modeling from 4D MR images of liver simulating phantom.

Authors:  Henna Kavaluus; Lauri Koivula; Eero Salli; Tiina Seppälä; Kauko Saarilahti; Mikko Tenhunen
Journal:  J Appl Clin Med Phys       Date:  2022-04-12       Impact factor: 2.243

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.