Literature DB >> 17260361

Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound.

Baudouin Denis de Senneville1, Charles Mougenot, Chrit T W Moonen.   

Abstract

Focused ultrasound (US) is a unique and noninvasive technique for local deposition of thermal energy deep inside the body. MRI guidance offers the additional benefits of excellent target visualization and continuous temperature mapping. However, treating a moving target poses severe problems because 1) motion-related thermometry artifacts must be corrected, 2) the US focal point must be relocated according to the target displacement. In this paper a complete MRI-compatible, high-intensity focused US (HIFU) system is described together with adaptive methods that allow continuous MR thermometry and therapeutic US with real-time tracking of a moving target, online motion correction of the thermometry maps, and regional temperature control based on the proportional, integral, and derivative method. The hardware is based on a 256-element phased-array transducer with rapid electronic displacement of the focal point. The exact location of the target during US firing is anticipated using automatic analysis of periodic motions. The methods were tested with moving phantoms undergoing either rigid body or elastic periodical motions. The results show accurate tracking of the focal point. Focal and regional temperature control is demonstrated with a performance similar to that obtained with stationary phantoms. Copyright (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17260361     DOI: 10.1002/mrm.21124

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

1.  The effect of electronically steering a phased array ultrasound transducer on near-field tissue heating.

Authors:  Allison Payne; Urvi Vyas; Nick Todd; Joshua de Bever; Douglas A Christensen; Dennis L Parker
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

2.  Hybrid referenceless and multibaseline subtraction MR thermometry for monitoring thermal therapies in moving organs.

Authors:  William A Grissom; Viola Rieke; Andrew B Holbrook; Yoav Medan; Michael Lustig; Juan Santos; Michael V McConnell; Kim Butts Pauly
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

3.  Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry.

Authors:  Jing Yuan; Chang-Sheng Mei; Lawrence P Panych; Nathan J McDannold; Bruno Madore
Journal:  Quant Imaging Med Surg       Date:  2012

4.  Influence of geometric and material properties on artifacts generated by interventional MRI devices: Relevance to PRF-shift thermometry.

Authors:  Ken Tatebe; Elizabeth Ramsay; Charles Mougenot; Mohammad Kazem; Hamed Peikari; Michael Bronskill; Rajiv Chopra
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

Review 5.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

Review 6.  MR thermometry for monitoring tumor ablation.

Authors:  Baudouin Denis de Senneville; Charles Mougenot; Bruno Quesson; Iulius Dragonu; Nicolas Grenier; Chrit T W Moonen
Journal:  Eur Radiol       Date:  2007-05-22       Impact factor: 5.315

Review 7.  MR-guided focused ultrasound surgery, present and future.

Authors:  David Schlesinger; Stanley Benedict; Chris Diederich; Wladyslaw Gedroyc; Alexander Klibanov; James Larner
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

8.  Focal therapy for localized prostate cancer -choosing the middle ground.

Authors:  Uri Lindner; John Trachtenberg
Journal:  Can Urol Assoc J       Date:  2009-08       Impact factor: 1.862

9.  Accurate MR thermometry by hyperpolarized 129 Xe.

Authors:  Le Zhang; Alex Burant; Andrew McCallister; Victor Zhao; Karl M Koshlap; Simone Degan; Michael Antonacci; Rosa Tamara Branca
Journal:  Magn Reson Med       Date:  2016-10-19       Impact factor: 4.668

10.  Evaluation of referenceless thermometry in MRI-guided focused ultrasound surgery of uterine fibroids.

Authors:  Nathan McDannold; Clare Tempany; Ferenc Jolesz; Kullervo Hynynen
Journal:  J Magn Reson Imaging       Date:  2008-10       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.