Validation of a new closed circuit indirect calorimetry method compared with the open Douglas bag method.

J M Raurich1, J Ibañez, P Marse.   

Abstract

New equipment designed for the routine measurement of oxygen uptake (VO2) using a closed circuit method has been validated by comparing it with a standard Douglas bag method. The equipment (The Caloric Measurement Unit, CMU) has been tested in 10 critically ill patients during mechanical ventilation (MV) and in 10 spontaneously breathing healthy subjects. Determinations of VO2 and of the resting energy expenditure (REE) were measured in duplicate with the standard method and once with the CMU. Six additional patients receiving MV were studied with the CMU to evaluate the reproducibility and the effect of FIO2 = 1 vs FIO2 = 0.43 on VO2 measurements. Considering the whole group of 10 patients and 10 subjects, the mean difference of VO2 between both methods was -2 +/- 21 ml/min (95% confidence interval, -11.8 to 7.8 ml/min, p = 0.6) standard deviation. Both methods had a similar reproducibility and the mean difference of VO2 measured at the two different FIO2 with the CMU was -3.2 +/- 11 ml/min (95% confidence interval, -14.7 to 8.4 ml/min, p = 0.5). No statistically significant difference was found between derived REE values obtained from either method. These data show a good correlation between the two methods suggesting that CMU may be used in place of the standard method with the same accuracy in measurement of VO2 even at FIO2 = 1.

Entities:  

Mesh:

Year:  1989        PMID: 2745871     DOI: 10.1007/bf00271067

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  21 in total

1.  Effect of immediate postoperative nutritional support on length of hospitalization.

Authors:  J Askanazi; T W Hensle; P M Starker; S H Lockhart; P A LaSala; C Olsson; J M Kinney
Journal:  Ann Surg       Date:  1986-03       Impact factor: 12.969

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Clinical implications of continuous measurement of energy expenditure in mechanically ventilated patients.

Authors:  M Carlsson; J Nordenström; G Hedenstierna
Journal:  Clin Nutr       Date:  1984-07       Impact factor: 7.324

4.  Gas exchange during ventilator treatment: a validation of a computerized technique and its comparison with the Douglas bag method.

Authors:  S Bredbacka; S Kawachi; O Norlander; B Kirk
Journal:  Acta Anaesthesiol Scand       Date:  1984-08       Impact factor: 2.105

5.  Analysis of error in the determination of respiratory gas exchange at varying FIO2.

Authors:  J S Ultman; S Bursztein
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1981-01

6.  Clinical validation of a new metabolic monitor suitable for use in critically ill patients.

Authors:  L D Nelson; H B Anderson; H Garcia
Journal:  Crit Care Med       Date:  1987-10       Impact factor: 7.598

7.  Morphine and postoperative rewarming in critically ill patients.

Authors:  J L Rodriguez; C Weissman; M C Damask; J Askanazi; A I Hyman; J M Kinney
Journal:  Circulation       Date:  1983-12       Impact factor: 29.690

8.  The energy expenditure of the mechanically ventilated critically ill patient. An analysis.

Authors:  C Weissman; M Kemper; D H Elwyn; J Askanazi; A I Hyman; J M Kinney
Journal:  Chest       Date:  1986-02       Impact factor: 9.410

9.  A systematic method for validation of gas exchange measurements.

Authors:  M C Damask; C Weissman; J Askanazi; A I Hyman; S H Rosenbaum; J M Kinney
Journal:  Anesthesiology       Date:  1982-09       Impact factor: 7.892

10.  Metabolic and nutritional evaluation of patients supported with mechanical ventilation.

Authors:  F D Hunker; C W Bruton; E M Hunker; R M Durham; C L Krumdieck
Journal:  Crit Care Med       Date:  1980-11       Impact factor: 7.598

View more
  4 in total

1.  Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation.

Authors:  J Lynch; H Kaemmerer
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

Review 2.  Classical experiments in whole-body metabolism: closed-circuit respirometry.

Authors:  Bruno Archiza; Joseph F Welch; A William Sheel
Journal:  Eur J Appl Physiol       Date:  2017-07-26       Impact factor: 3.078

3.  Sexually dimorphic effects of prenatal diazepam exposure on respiratory control and the monoaminergic system of neonate and young rats.

Authors:  Carlos Aparecido da Silva Junior; Luís Gustavo A Patrone; Vivian Biancardi; Heloísa H Vilela-Costa; Danuzia A Marques; Caroline Cristina-Silva; Kaoma Stephani da Costa Silva; Kênia C Bícego; Raphael E Szawka; Luciane H Gargaglioni
Journal:  Pflugers Arch       Date:  2022-07-25       Impact factor: 4.458

4.  Clinical validation of the Deltatrac monitoring system in mechanically ventilated patients.

Authors:  S Tissot; B Delafosse; O Bertrand; Y Bouffard; J P Viale; G Annat
Journal:  Intensive Care Med       Date:  1995-02       Impact factor: 17.440

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.