| Literature DB >> 27455473 |
Daniel C Pavord1, Steven Birnbaum, Douglas Bocuzzi, Steven deBoer, D Jay Freedman, Michael Schell, Steven Sutlief.
Abstract
The goal of this report is to provide a framework from which an institution can develop a competency and credentialing program. It is not intended to be adopted as written, but rather as a list of suggestions from which the institution develops their program. A clear distinction should be made between the initial evaluation of the competency of new staff (credentialing) and the ongoing verification of the competency of existing staff. Furthermore, whenever new technologies are imple-mented, the entire staff would be subject to the credentialing process. Competencies involve the ongoing verification of the performance of a procedure according to the established policies and procedures at a facility. This can be done by audits of work product, direct observation of performance, self-evaluation, or testing. PACS number(s): 87.10.-e, 87.90.+yEntities:
Mesh:
Year: 2016 PMID: 27455473 PMCID: PMC5690041 DOI: 10.1120/jacmp.v17i4.5804
Source DB: PubMed Journal: J Appl Clin Med Phys ISSN: 1526-9914 Impact factor: 2.102
Sample list of competency assessments and minimum number of procedures performed per year
|
|
|
|
|---|---|---|
| Second check of treatment plan | Audit | 12 |
| Chart check | Audit | 50 |
| Patient specific IMRT QA | Audit | 4 |
| Treatment planning general | Audit | 12 |
| Treatment planning special procedure | Audit | 4 |
| Routine equipment QA | Observation | 1 |
| Output calibration | Outside audit (IROC or RDS) | 1 |
| Radioactive source strength calibration | Observation | 1 |
| Brachytherapy | Observation | 4 |
| Intraoperative radiation therapy | Observation | 4 |
| SRS/SBRT | Observation | 4 |
| Radiation Safety | Quiz | NA |
Competencies
|
|
|
|
|
|
|---|---|---|---|---|
| Second check | AAPM TG40 | Audit | 12 | |
| Chart check | AAPM TG40 | Audit | 50 | |
| Patient specific IMRT QA | Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee | Audit | 4 | |
| Routine equipment QA | NY State part 16 | AAPM Task Group reports 40,142 | Observation | 1 |
| Output calibration | NY State part 16 | AAPM TG51, AAPM Report 99 | Outside audit | 1 |
| Radioactive source strength calibration | AAPM TG56 | Observation | 1 | |
| HDR | NY State part 16 | AAPM TG59 | Observation | 4 |
| Seed implants | AAPM TG56, AAPM Report 137, AAPM Report 128, AAPM TG64 | Observation | 4 | |
| Intraoperative radiation therapy | AAPM Report 152, AAPM TG72 | Observation | 4 | |
| SRS | AAPM TG42 | Observation | 4 | |
| SBRT | AAPM Report 101 | Observation | 4 | |
| Radiation Safety | AAPM Report 160 | Test | NA |
Sample form for credentialized staff
|
|
|
|
|---|---|---|
| Second check | ||
| Chart check | ||
| Patient specific IMRT QA | ||
| Routine equipment QA | ||
| Output calibration | ||
| Radioactive source strength calibration | ||
| HDR | ||
| Seed implants | ||
| Intraoperative radiation therapy | ||
| SRS | ||
| SBRT |
Samples of staff competency record, audit form of previously performed procedures, and evaluation form
|
| |||||
|---|---|---|---|---|---|
| Staff Name: John Doe | |||||
| Date of Hire: 1–1‐2008 | |||||
| Competencies: | |||||
|
|
|
|
|
|
|
| Second check | 1–10‐2008 | 1–30‐2010 | 12 | 200 | Documentation of number of procedures and competency audit form. |
| Chart check | 1–13‐2008 | 50 | 500 | Documentation of number of procedures and competency audit form. | |
| Patient specific IMRT QA | 1–20‐2008 | 4 | 60 | Documentation of number of procedures and competency audit form. | |
| Routine equipment QA | 1–30‐2008 | 1 | 6 | Copy of QA records and competency audit form. | |
| Output calibration | 2–15‐2008 | 1 | 2 | Outside audit results and copy of calibration reports | |
| Radioactive source strength calibration | 3–15‐2008 | 1 | 9 | Copy of calibration report and competency evaluation form. | |
| HDR | 2–10‐2008 | 4 | 24 | Documentation of number of procedures and competency evaluation form. | |
| Seed implants | 3–20‐2008 | 4 | 6 | Documentation of number of procedures and competency evaluation form. | |
| Intraoperative radiation therapy | 4–15‐2008 | 4 | 2 | Documentation of number of procedures and competency evaluation form. | |
| SRS | 9–1‐2008 | 4 | 6 | Documentation of number of procedures and competency evaluation form. | |
| SBRT | 8–1‐2008 | 4 | 10 | Printout from department information system documenting number of procedures and competency evaluation form. | |
| Radiation Safety | 1–4‐2008 | NA | NA | Outline of safety in‐service and quiz result. DOT training documentation. |
Notes: John Doe has not completed minimum number of IORT procedures in the last year. Must be re‐credentialed prior to performing independently.
|
|
|---|
| Procedure |
| Items audited |
| Staff performing audit |
| Dates and number of procedures audited |
| Result of audit |
| Is staff member competent (yes/no)? |
|
|
| Procedure |
| Items observed |
| Staff performing evaluation |
| Dates and number of procedures evaluated |
| Result of evaluation |
| Is staff member competent (yes/no)? |