Literature DB >> 27449525

A Comparison of Screw Fixation and Suture-Button Fixation in a Syndesmosis Injury in an Ankle Fracture.

Jung-Han Kim1, Heui-Chul Gwak2, Chang-Rack Lee1, Hye-Jeung Choo3, Jeon-Gyo Kim4, Dae-Yoo Kim5.   

Abstract

The present study compared the quality of reduction and the clinical assessment between screw fixation and suture-button fixation with an ankle fracture accompanied by syndesmosis injury. We studied the clinical and radiologic findings 1 year postoperatively through retrospective examination of 24 patients who had undergone screw fixation from January 2011 to December 2012 and prospective examination of 20 patients who had undergone suture button fixation from January 2013 to May 2014. Regarding the tibiofibular clear space, tibiofibular overlap, and medial clear space, the screw fixation group had improvement from a preoperative mean of 6.97 (range 2.79 to 15.81) mm, 4.43 (range 0 to 7.87) mm, 7.90 (range 4.24 to 19.50) mm to a postoperative mean of 4.95 (range 2.72 to 9.08) mm, 6.29 (range 0 to 10.37) mm, and 4.32 (range 1.98 to 6.57) mm, respectively. The corresponding improvement for the suture-button fixation group was from a preoperative mean of 6.65 (range 3.94 to 13.73) mm, 5.39 (range 0 to 9.44) mm, 7.27 (range 4.04 to 16.00) mm to a postoperative mean of 5.15 (range 2.93 to 7.30) mm, 7.21 (range 2.15 to 10.30) mm, and 4.25 (range 2.97 to 5.71) mm. No statistically significant difference was found between the 2 techniques. Both suture-button and metal screw fixation are effective treatment methods for an ankle fracture accompanied by syndesmosis injury. However, a long-term and prospective analysis is needed.
Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Tightrope(®); ankle fracture; screw fixation; syndesmosis injury

Mesh:

Year:  2016        PMID: 27449525     DOI: 10.1053/j.jfas.2016.05.002

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  14 in total

1.  Dynamic fixation is superior in terms of clinical outcomes to static fixation in managing distal tibiofibular syndesmosis injury.

Authors:  Kaifeng Gan; Dingli Xu; Keqi Hu; Wei Wu; Yandong Shen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-08-17       Impact factor: 4.342

Review 2.  Imaging in syndesmotic injury: a systematic literature review.

Authors:  Nicola Krähenbühl; Maxwell W Weinberg; Nathan P Davidson; Megan K Mills; Beat Hintermann; Charles L Saltzman; Alexej Barg
Journal:  Skeletal Radiol       Date:  2017-11-30       Impact factor: 2.199

Review 3.  Management of acute injuries of the tibiofibular syndesmosis.

Authors:  Nicholas M Fort; Amiethab A Aiyer; Jonathan R Kaplan; Niall A Smyth; Anish R Kadakia
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-04-08

Review 4.  A meta-analysis comparing the outcomes of syndesmotic injury treated with metal screw, dynamic fixation, and bioabsorbable screw.

Authors:  Jiayong Liu; Gautam Pathak; Mihir Joshi; Kyle Andrews; Joseph Lee
Journal:  J Orthop       Date:  2021-04-24

Review 5.  Acute syndesmotic injuries in ankle fractures: From diagnosis to treatment and current concepts.

Authors:  Francesco Pogliacomi; Massimo De Filippo; Daniele Casalini; Alberto Longhi; Fabrizio Tacci; Rocco Perotta; Francesco Pagnini; Silvio Tocco; Francesco Ceccarelli
Journal:  World J Orthop       Date:  2021-05-18

6.  A comparison of double single suture-button fixation, suture-button fixation, and screw fixation for ankle syndesmosis injury: A retrospective cohort study.

Authors:  Alper Kurtoglu; Alauddin Kochai; Mustafa Erkan Inanmaz; Erhan Sukur; Dogan Keskin; Mehmet Türker; Mustafa Uysal; Zafer Sen; Ismail Daldal
Journal:  Medicine (Baltimore)       Date:  2021-04-02       Impact factor: 1.889

Review 7.  A systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury.

Authors:  Pei Zhang; Yuan Liang; Jinshan He; Yongchao Fang; Pengtao Chen; Jingcheng Wang
Journal:  BMC Musculoskelet Disord       Date:  2017-07-04       Impact factor: 2.362

8.  Dynamic Fixation versus Static Fixation in Treatment Effectiveness and Safety for Distal Tibiofibular Syndesmosis Injuries: A Systematic Review and Meta-Analysis.

Authors:  Xiao Fan; Peng Zheng; Ying-Yu Zhang; Zeng-Tao Hou
Journal:  Orthop Surg       Date:  2019-12       Impact factor: 2.071

9.  Syndesmotic malreduction may decrease fixation stability: a biomechanical study.

Authors:  Lu Bai; Wentao Zhang; Siyao Guan; Jianxin Liu; Peng Chen
Journal:  J Orthop Surg Res       Date:  2020-02-21       Impact factor: 2.359

10.  Comparison of suture-button and screw fixation in the treatment of ankle syndesmotic injuries: Cohort study protocol.

Authors:  Xiaoning Liu; Guang Jin; Chengdong Piao; Zhuan Zhong; Fei Chang; Bingzhe Huang
Journal:  Medicine (Baltimore)       Date:  2020-08-07       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.