Literature DB >> 27446546

Harmonic versus LigaSure hemostasis technique in thyroid surgery: A meta-analysis.

Arun Upadhyaya1, Tianpeng Hu1, Zhaowei Meng1, Xue Li1, Xianghui He2, Weijun Tian2, Qiang Jia1, Jian Tan1.   

Abstract

Harmonic scalpel and LigaSure vessel sealing systems have been suggested as options for saving surgical time and reducing postoperative complications. The aim of the present meta-analysis was to compare surgical time, postoperative complications and other parameters between them in for the open thyroidectomy procedure. Studies were retrieved from MEDLINE, Cochrane Library, EMBASE and ISI Web of Science until December 2015. All the randomized controlled trials (RCTs) comparing Harmonic scalpel and LigaSure during open thyroidectomy were selected. Following data extraction, statistical analyses were performed. Among the 24 studies that were evaluated for eligibility, 7 RCTs with 981 patients were included. The Harmonic scalpel significantly reduced surgical time compared with LigaSure techniques (8.79 min; 95% confidence interval, -15.91 to -1.67; P=0.02). However, no significant difference was observed for the intraoperative blood loss, postoperative blood loss, duration of hospital stay, thyroid weight and serum calcium level postoperatively in either group. The present meta-analysis indicated superiority of Harmonic Scalpel only in terms of surgical time compared with LigaSure hemostasis techniques in open thyroid surgery.

Entities:  

Keywords:  Harmonic scalpel; LigaSure; randomized controlled trials; thyroid surgery

Year:  2016        PMID: 27446546      PMCID: PMC4950612          DOI: 10.3892/br.2016.691

Source DB:  PubMed          Journal:  Biomed Rep        ISSN: 2049-9434


  39 in total

1.  The use of Ligasure Vessel Sealing System in thyroid surgery.

Authors:  Vassilios A Lachanas; Emmanuel P Prokopakis; Antonios A Mpenakis; Alexander D Karatzanis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-03       Impact factor: 3.497

2.  Laparoscopic liver resection using a bipolar vessel-sealing device: LigaSure.

Authors:  Douglas P Slakey
Journal:  HPB (Oxford)       Date:  2008       Impact factor: 3.647

Review 3.  Ultrasonic coagulator for thyroidectomy: a systematic review of randomized controlled trials.

Authors:  Zong-jiu Zhang; Peng Zhang; Jin-hui Tian; Jun Li; Lun Li; Jing Tian; Ke-hu Yang
Journal:  Surg Innov       Date:  2010-03       Impact factor: 2.058

4.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.

Authors:  David Moher; Alessandro Liberati; Jennifer Tetzlaff; Douglas G Altman
Journal:  Int J Surg       Date:  2010-02-18       Impact factor: 6.071

5.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.

Authors:  Allan E Siperstein; Eren Berber; Ebru Morkoyun
Journal:  Arch Surg       Date:  2002-02

6.  Risk of bias reporting in Cochrane systematic reviews.

Authors:  Lisa Hopp
Journal:  Int J Nurs Pract       Date:  2014-03-12       Impact factor: 2.066

7.  The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS.

Authors:  Gianlorenzo Dionigi; Luigi Boni; Stefano Rausei; Francesco Frattini; Cesare Carlo Ferrari; Alberto Mangano; Andrea Leotta; Marco Franchin
Journal:  Langenbecks Arch Surg       Date:  2012-01-10       Impact factor: 3.445

8.  Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy.

Authors:  Yoann Pons; Jérome Gauthier; Elsa Ukkola-Pons; Philippe Clément; Eric Roguet; Jean-Luc Poncet; Claude Conessa
Journal:  Otolaryngol Head Neck Surg       Date:  2009-10       Impact factor: 3.497

9.  A comparison of two methods of hemostasis in thyroidectomy.

Authors:  Michael M McNally; Steven C Agle; R Fredrick Williams; Walter E Pofahl
Journal:  Am Surg       Date:  2009-11       Impact factor: 0.688

10.  Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement.

Authors:  David Moher; Larissa Shamseer; Mike Clarke; Davina Ghersi; Alessandro Liberati; Mark Petticrew; Paul Shekelle; Lesley A Stewart
Journal:  Syst Rev       Date:  2015-01-01
View more
  6 in total

1.  Thyroidectomy with energy-based devices: surgical outcomes and complications-comparison between Harmonic Focus, LigaSure Small Jaw and Thunderbeat Open Fine Jaw.

Authors:  Gian Luigi Canu; Fabio Medas; Francesco Podda; Alberto Tatti; Giuseppe Pisano; Enrico Erdas; Pietro Giorgio Calò
Journal:  Gland Surg       Date:  2020-06

2.  An advanced bipolar device helps reduce the rate of postoperative pancreatic fistula in laparoscopic gastrectomy for gastric cancer patients: a propensity score-matched analysis.

Authors:  Kazunori Shibao; Shinsaku Honda; Yasuhiro Adachi; Shiro Kohi; Yuzan Kudou; Nobutaka Matayoshi; Nagahiro Sato; Keiji Hirata
Journal:  Langenbecks Arch Surg       Date:  2022-10-01       Impact factor: 2.895

3.  The Use of Harmonic Focus and Thunderbeat Open Fine Jaw in Thyroid Surgery: Experience of a High-Volume Center.

Authors:  Gian Luigi Canu; Fabio Medas; Federico Cappellacci; Francesco Casti; Raffaela Bura; Enrico Erdas; Pietro Giorgio Calò
Journal:  J Clin Med       Date:  2022-05-29       Impact factor: 4.964

4.  LigaSure versus monopolar cautery for recipient hepatectomy in liver transplantation: a propensity score-matched analysis.

Authors:  Jeong-Moo Lee; Kwangpyo Hong; Eui Soo Han; Sanggyun Suh; Suyoung Hong; Suk Kyun Hong; YoungRok Choi; Nam-Joon Yi; Kwang-Woong Lee; Kyung-Suk Suh
Journal:  Ann Transl Med       Date:  2021-07

5.  Parathyroid hormone level after total thyroidectomy using conventional versus harmonic focus technique: Prospective randomized study.

Authors:  Hany Abdelfatah Elhady; Rasha Abd Elaziz Abd Elghany; Mohammed Shehata Zarad
Journal:  Ann Med Surg (Lond)       Date:  2021-12-14

6.  Impact of scalpel type on operative time and acute complications in thyroidectomies.

Authors:  Tamires Santos Fraga; Hugo Fontan Köhler; Thiago Celestino Chulam; Luiz Paulo Kowalski
Journal:  Braz J Otorhinolaryngol       Date:  2019-10-03
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.