Literature DB >> 22230963

The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS.

Gianlorenzo Dionigi1, Luigi Boni, Stefano Rausei, Francesco Frattini, Cesare Carlo Ferrari, Alberto Mangano, Andrea Leotta, Marco Franchin.   

Abstract

PURPOSE: The options for haemostasis and dissection during modern thyroid surgery include the use of a bipolar vessel sealing system and ultrasonic technology. The aim of this study was to compare these energy-based devices (EBDs) with respect to their use in open thyroidectomy.
METHODS: The FOCUS Shear (F) and LigaSure LF1212 (L) were evaluated. A total of 182 consecutive patients scheduled for open thyroidectomy were prospectively randomised into two similarly sized groups. The parameters of operative time, morbidity, incision length, postoperative pain and hospital stay were analysed.
RESULTS: The main clinically primary endpoints of the two devices were identical in the study as the rate of nerve lesions, bleeding, drainage, operative time and postoperative calcium concentration with no significant differences with respect to the instrument utilised. The mean length of the incision was greater in the F group (p < 0.05). Patients in the F group were more likely to complain of pain while swallowing (p < 0.001). Early postoperative measurements of intact parathyroid hormone plasma levels revealed that although the levels were within the reference range, they were significantly lower in the F group (p < 0.001). Oral calcium supplementation was significantly higher and more prolonged in the F group.
CONCLUSIONS: The present study demonstrated no significant difference in the rates of postoperative morbidity associated with these two different EBDs used. Differences in clinically less significant were founded and focused on.

Entities:  

Mesh:

Year:  2012        PMID: 22230963     DOI: 10.1007/s00423-011-0898-0

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  19 in total

1.  Real-time thermography during energized vessel sealing and dissection.

Authors:  P A Campbell; A B Cresswell; T G Frank; A Cuschieri
Journal:  Surg Endosc       Date:  2003-07-21       Impact factor: 4.584

2.  The use of Ligasure Vessel Sealing System in thyroid surgery.

Authors:  Vassilios A Lachanas; Emmanuel P Prokopakis; Antonios A Mpenakis; Alexander D Karatzanis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-03       Impact factor: 3.497

Review 3.  Influence of new technologies on thyroid surgery: state of the art.

Authors:  Gianlorenzo Dionigi; Alessandro Bacuzzi; Luigi Boni; Francesca Rovera; Eliana Piantanida; Maria Laura Tanda; Mario Diurni; Giulio Carcano; Bartalena Luigi; Salvatore Cuffari; Renzo Dionigi
Journal:  Expert Rev Med Devices       Date:  2005-09       Impact factor: 3.166

4.  Impact of modern technologies on quality of thyroid surgery.

Authors:  Henning Dralle
Journal:  Langenbecks Arch Surg       Date:  2006-02       Impact factor: 3.445

Review 5.  Thyroid surgery: new approach to dissection and hemostasis.

Authors:  Gianlorenzo Dionigi; Luigi Boni; Francesca Rovera; Renzo Dionigi
Journal:  Surg Technol Int       Date:  2006

6.  Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments.

Authors:  Gianlorenzo Dionigi
Journal:  Langenbecks Arch Surg       Date:  2008-12-24       Impact factor: 3.445

7.  Randomized controlled trial of harmonic scalpel use during thyroidectomy.

Authors:  Paolo Miccoli; Piero Berti; Gianlorenzo Dionigi; Gian L Dionigi; Jacopo D'Agostino; Cinzia Orlandini; Gianluca Donatini
Journal:  Arch Otolaryngol Head Neck Surg       Date:  2006-10

8.  The use of LigaSure in patients with hyperthyroidism.

Authors:  Umut Barbaros; Yeşim Erbil; Alp Bozbora; Uğur Deveci; Nihat Aksakal; Ahmet Dinççağ; Selçuk Ozarmağan
Journal:  Langenbecks Arch Surg       Date:  2006-09-06       Impact factor: 3.445

9.  Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma.

Authors:  Carter T Smith; Barbara Zarebczan; Amal Alhefdhi; Herbert Chen
Journal:  J Surg Res       Date:  2011-03-29       Impact factor: 2.192

10.  Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique.

Authors:  Jan Franko; Karen J Kish; Christopher M Pezzi; Ho Pak; John S Kukora
Journal:  Am Surg       Date:  2006-02       Impact factor: 0.688

View more
  25 in total

1.  Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience.

Authors:  Serkan Teksoz; Yusuf Bukey; Murat Ozcan; Akif Enes Arikan; Ates Ozyegin
Journal:  Updates Surg       Date:  2013-08-29

Review 2.  ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis.

Authors:  Pietro Contin; Käthe Gooßen; Kathrin Grummich; Katrin Jensen; Hubertus Schmitz-Winnenthal; Markus W Büchler; Markus K Diener
Journal:  Langenbecks Arch Surg       Date:  2013-11-16       Impact factor: 3.445

3.  Thyroid surgery without antibiotic prophylaxis: experiences with 1,030 patients from a teaching hospital in China.

Authors:  Qian Qin; Hong Li; Li-Bin Wang; Ai-Hui Li; Li-Ju Chen; Qiang Lu
Journal:  World J Surg       Date:  2014-04       Impact factor: 3.352

Review 4.  Safety of energy based devices for hemostasis in thyroid surgery.

Authors:  Gianlorenzo Dionigi; Che-Wei Wu; Hoon-Yub Kim; Xiaoli Liu; Renbin Liu; Gregory W Randolph; Angkoon Anuwong
Journal:  Gland Surg       Date:  2016-10

5.  LigaSure small jaws versus cold knife dissection in superficial parotidectomy.

Authors:  Christoffer Holst Hahn; Christian Hjort Sørensen
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-10-02       Impact factor: 2.503

6.  Reply to the commentary by Dr. Sauerland S. and Dr. Gross CTR.

Authors:  Gianlorenzo Dionigi; Markus W Büchler; Martin Schneider; Stefan Sauerland; Christian T R Gross
Journal:  Langenbecks Arch Surg       Date:  2012-10-13       Impact factor: 3.445

7.  Questions on randomised trials by Dionigi and coworkers.

Authors:  Stefan Sauerland; Christian T R Gross
Journal:  Langenbecks Arch Surg       Date:  2013-03-05       Impact factor: 3.445

8.  Which hemostatic surgical devices should be used for thyroid surgery, or should we just continue to clamp and tie?

Authors:  Samira M Sadowski; Electron Kebebew
Journal:  Thyroid       Date:  2013-08-03       Impact factor: 6.568

9.  A new hemostatic clip for endoscopic surgery that can maintain blood flow after clipping.

Authors:  Kyoung Won Nam; Sang Bong Lee; In Young Kim; Kwang Gi Kim; Sang Jae Park
Journal:  World J Gastroenterol       Date:  2014-02-07       Impact factor: 5.742

Review 10.  Prevention and management of bleeding in thyroid surgery.

Authors:  Gabriele Materazzi; Carlo Enrico Ambrosini; Lorenzo Fregoli; Luigi De Napoli; Gianluca Frustaci; Valeria Matteucci; Piermarco Papini; Sohail Bakkar; Paolo Miccoli
Journal:  Gland Surg       Date:  2017-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.