Anthony Danso-Appiah1, Jonathan Minton2, Daniel Boamah3, Joseph Otchere4, Richard H Asmah5, Mark Rodgers6, Kwabena M Bosompem4, Paolo Eusebi7, Sake J De Vlas8.
Abstract
OBJECTIVE: To assess the accuracy of point-of-care testing for circulatory cathodic antigen in the diagnosis of schistosome infection.Entities:
Mesh:
Substances:
Year: 2016 PMID: 27429491 PMCID: PMC4933137 DOI: 10.2471/BLT.15.158741
Source DB: PubMed Journal: Bull World Health Organ ISSN: 0042-9686 Impact factor: 9.408
Fig. 1Selection of studies included in the systematic review and meta-analysis on the accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection
Characteristics of the studies included in the systematic review and meta-analysis on the accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection
| Study | Country | Year | No. of study communities | Initial sample size | Participants | Ages (years) | Prevalence (%) | CCA test investigated, and no. of samples per participant | No. of stool samples per participant |
|---|---|---|---|---|---|---|---|---|---|
| Kremsner, 1994 | Cameroon | NR | 1 | 148 | Schoolchildren | 4–13 | NR | EIA (1) | 1 |
| De Clercq, 1997 | Mali | NR | 2 | NRc | Adults and children | NR | 99.0 | ELISA (1) | 2 |
| De Clercq, 1997 | Mali | 1993 | 4 | NRd | Adults and children | NR | NR | ELISA (1) | 1 |
| Legesse, 2007 | Ethiopia | 2007 | 1 | 251 | Adults and children | > 5 | 90.0 (schoolchildren) | Reagent strip (1) | 1 |
| Ayele, 2008 | Ethiopia | NR | 1 | 206 | Schoolchildren | 4–21 | 47.6 | Reagent strip (1) | NA |
| Legesse, 2008 | Ethiopia | 2007 | 1 | 184 | Schoolchildren | 5–22 | 36.4 | Reagent strip (1) | 1 |
| Midzi, 2009 | Zimbabwe | 2006 | 1 | 265 | Preschool children and schoolchildren | 2–19 | 40.4 | Reagent strip (1) | 1 |
| Stothard, 2009 | Uganda | 2009 | 1 | 242 | Infants and preschool children | < 6 | > 50.0 | Reagent strip (1) | 2 |
| Sousa-Figueiredo, 2010 | Uganda | 2007 and 2009 | NR | 608 | Preschool children and mothers | < 7e | 16.0 and 43.3 (children), 29.2 and 60.0 (mothers) from either Lake Victoria or Lake Albert | Cassette (1) | 2 |
| Standley, 2010 | Kenya, United Republic of Tanzania | 2009 | 11 | 171 | Schoolchildren | 6–17 | 68.6 | Reagent strip (1) | 1 |
| Coulibaly, 2011 | Côte d’Ivoire | 2010 | 1 | 146 | Children | 8–12 | 32.9 | Cassette (1, 2 or 3) | 1, 2 or 3 |
| Coulibaly, 2011 | Côte d’Ivoire | 2010 | 1 | 130 | Children | 8–12 | 53.1 | Cassette (1, 2 or 3) | 1, 2 or 3 |
| Coulibaly, 2011 | Côte d’Ivoire | 2010 | 1 | 170 | Children | 8–12 | 91.8 | Cassette (1, 2 or 3) | 1, 2 or 3 |
| Shane, 2011 | Kenya | 2007 | 1 | 484 | Children | 1–15 | 38.8 | Dipstick (1) | 3 |
| Tchuem Tchuenté, 2012 | Cameroon | 2010/2011 | 1 | 765 | Schoolchildren | 8–12 | 21.0 | Cassette (1) and dipstick (NR) | 3 |
| Tchuem Tchuenté, 2012 | Cameroon | 2010/2011 | 1 | 765 | Schoolchildren | 8–12 | 41.8 | Cassette (1) and dipstick (NR) | 3 |
| Tchuem Tchuenté, 2012 | Cameroon | 2010/2011 | 1 | 765 | Schoolchildren | 8–12 | 31.4 | Cassette (1) and dipstick (NR) | 3 |
| Colley, 2013 | Cameroon, Côte d’Ivoire, Ethiopia, Kenya, Uganda | 2010 | 5 | 4305 | Schoolchildren | 9–12 | 15.1 (Kenya), 25.0 (Uganda), 38.4 (Cameroon), 43.0 (Ethiopia) and 47.9 (Côte d’Ivoire) | Cassette (1) | 1 |
| Coulibaly, 2013 | Côte d’Ivoire | 2011 | 2 | 242 | Preschool children | < 6 | 23.1 | Cassette (2) | 2 |
| Dawson, 2013 | Uganda | 2011 | NR | 82 | Preschool children | < 6 | 45.0 | Cassette (1) | 2 |
| Erko, 2013 | Ethiopia | 2010/2011 | 2 | 620 | Schoolchildren | 8–12 | 34.0 | Cassette (1, 2 or 3) | 1, 2 or 3 |
| Koukounari, 2013 | Uganda | 2005 | 1 | 446 | Children and adults | 7–16 and 17–76 | NR | Cassette (1) | 3 |
| Sousa-Figueiredo, 2013 | Uganda | 2009 | NR | 333 | Preschool children | < 7 | 7.2 | Dipstick (1) | 1 |
| Sousa-Figueiredo, 2013 | Uganda | 2009 | NR | 337 | Preschool children | < 7 | 16.9 | Dipstick (1) | 1 |
| Sousa-Figueiredo, 2013 | Uganda | 2009 | NR | 255 | Preschool children | < 7 | 38.8 | Dipstick (1) | 1 |
| Adriko, 2014 | Uganda | NR | 5 | 500 | Schoolchildren | 7–13 | 8.0, 23.0 and 36.0 from low, moderate and high endemic areas, respectively | Cassette (1) | 1, 2 or 3 |
CCA: circulatory cathodic antigen; EIA: enzyme immunoassay; ELISA: enzyme-linked immunosorbent assay; NA: not applicable; NR: not reported.
a Of infection with the schistosome species of interest, as indicated by the results of the reference test.
b Each examined as a duplicate Kato–Katz smear.
c Overall, 352 serum, 134 stool and 337 urine samples were investigated
d Overall, 348 blood, 324 stool and 431 urine samples were investigated.
e Reported age of children.
f The article was conducted in settings of low, moderate and high endemicity. We treated the publication as a report on three studies, which we designated studies 1, 2 and 3.
Fig. 2Single point-of-care testing for circulatory cathodic antigen in the detection of Schistosoma haematobium infection: summary receiver-operating characteristic curve
Fig. 3Accuracy of single point-of-care testing for circulatory cathodic antigen in the detection of Schistosoma mansoni infection
Fig. 4Single point-of-care testing for circulatory cathodic antigen in the detection of Schistosoma mansoni infection: summary receiver-operating characteristic curve
Fig. 5Accuracy of single point-of-care testing for circulatory cathodic antigen in the detection of Schistosoma mansoni infection
Fig. 6Accuracy of double or triple point-of-care testing for circulatory cathodic antigen in the detection of Schistosoma mansoni infection
Latent class analysis of the studies on the accuracy of point-of-care testing for circulatory cathodic antigen in the detection of schistosome infection included in the meta-analysis
| Latent class and study | CCA test investigated, and no. of samples per participant | No. of stool samples per participant |
|---|---|---|
| Coulibaly, 2011 | Cassette (1) | 1 |
| Coulibaly, 2011 (study 1) | Cassette (1) | 3 |
| Coulibaly, 2011 (study 1) | Cassette (3) | 3 |
| Coulibaly, 2011 (study 2) | Cassette (1) | 3 |
| Coulibaly, 2011 (study 2) | Cassette (3) | 3 |
| Coulibaly, 2011 (study 3) | Cassette (1) | 3 |
| Koukounari, 2013 (study 2) | Cassette (1) | 3 |
| Legesse, 2007 | Cassette (1) | 1b |
| Legesse, 2008 | Reagent strip (1) | 1b |
| Standley, 2010 | Cassette (1) | 1 |
| Shane, 2011 | Cassette (1) | 1 |
| Coulibaly, 2011 (study 3) | Cassette (3) | 3 |
| Tchuem Tchuenté, 2012 | Cassette (1) | 1 |
| Tchuem Tchuenté, 2012 (study 1) | Cassette (1) | 3 |
| Tchuem Tchuenté, 2012 (study 1) | Cassette (3) | 3 |
| Tchuem Tchuenté, 2012 (study 2) | Cassette (1) | 3 |
| Tchuem Tchuenté, 2012 (study 2) | Cassette (3) | 3 |
| Tchuem Tchuenté, 2012 (study 3) | Cassette (1) | 3 |
| Tchuem Tchuenté, 2012 (study 3) | Cassette (3) | 3 |
| Coulibaly, 2013 | Cassette (1) | 3 |
| Coulibaly, 2013 | Cassette (2) | 2 |
| Dawson, 2013 | Cassette (1) | 2 |
| Erko, 2013 | Cassette (1) | 1 |
| Erko, 2013 | Cassette (1) | 3 |
| Erko, 2013 | Cassette (3) | 3 |
| Koukounari, 2013 (study 1) | Cassette (1) | 3 |
| Sousa-Figueiredo, 2013 | Cassette (1) | 1 |
| Sousa-Figueiredo, 2013 (study 1) | Cassette (1) | 1 |
| Sousa-Figueiredo, 2013 (study 2) | Cassette (1) | 1 |
| Sousa-Figueiredo, 2013 (study 3) | Cassette (1) | 1 |
| Adriko, 2014 | Cassette (1) | 1 |
| Adriko, 2014 | Cassette (1) | 3 |
CCA: circulatory cathodic antigen.
a Each examined as a duplicate Kato–Katz smear.
b Stool samples were also checked by formol–ether concentration.