| Literature DB >> 27428975 |
Du Wang1,2, Zhaowei Zhang3,4, Peiwu Li5,6,7,8, Qi Zhang9,10,11, Wen Zhang12,13,14.
Abstract
Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.Entities:
Keywords: aflatoxin B1; food safety; soybean sauce; time-resolved fluorescent immunochromatographic strip
Mesh:
Substances:
Year: 2016 PMID: 27428975 PMCID: PMC4970140 DOI: 10.3390/s16071094
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1Schematic outlining the principle of competitive assay in immunochromatographic (IC) strip format.
Figure 2Different concentrations of AFB1 under UV light and portable TRFIA ((a) sample without AFB1; (b) sample with 5 µg·kg−1 AFB1; (c) sample with 10 µg·kg−1 AFB1).
Figure 3Standard curve by of soybean sauce sample.
The recovery and coefficients of variation (CVs) of time resolved fluorescent immunochromatographic (TRFIA) method.
| Sample | Number | Spike µg·kg−1 | Result by TRFIA µg·kg−1 | CV% | Recovery % | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | Mean | |||||
| Soybean sauce | 1 | ND | ND | ND | ND | ND | ND | - | - | - |
| 2 | 0.80 | 0.99 | 0.97 | 0.90 | 0.79 | 0.92 | 0.91 | 8.6 | 114.3 | |
| 3 | 4.00 | 4.57 | 3.88 | 3.69 | 4.33 | 4.22 | 4.14 | 8.5 | 103.5 | |
| 4 | 8.00 | 7.90 | 7.39 | 7.74 | 8.43 | 7.26 | 7.75 | 6.0 | 96.8 | |
| 5 | 12.00 | 11.45 | 11.98 | 13.01 | 12.89 | 12.87 | 12.44 | 5.7 | 103.7 | |
| Soybean sauce | 1 | ND | ND | ND | ND | ND | ND | - | - | - |
| 2 | 2.00 | 2.10 | 2.07 | 1.93 | 2.20 | 2.29 | 2.12 | 6.4 | 105.9 | |
| 3 | 5.00 | 5.02 | 5.24 | 5.46 | 5.34 | 5.09 | 5.23 | 3.4 | 104.6 | |
| 4 | 10.00 | 9.42 | 9.89 | 9.65 | 10.37 | 10.57 | 9.98 | 4.5 | 99.8 | |
| 5 | 15.00 | 12.98 | 12.07 | 13.58 | 13.12 | 13.68 | 13.09 | 5.0 | 87.2 | |
| Average | 6.0 | 110.0 | ||||||||
ND: “not detected”.
Intra- and inter- batch CV tests ofin TRFIA sensing.
| Soybean Sauce Sample | HPLC Detected AFB1 µg·kg−1 | Intra-Batch (n = 5) | Inter-Batch (n = 5) | ||
|---|---|---|---|---|---|
| Average Detected Value µg·kg−1 | Average CV % | Average Detected Value µg·kg−1 | Average CV % | ||
| 1# | ND | ND | - | ND | - |
| 2# | 0.8 | 0.69 | 7.9 | 0.68 | 8.7 |
| 3# | 3.2 | 3.43 | 4.6 | 3.58 | 5.2 |
| 4# | 8.9 | 9.30 | 5.3 | 9.20 | 5.6 |
| 5# | ND | ND | - | ND | - |
| 6# | 0.3 | 0.32 | 8.9 | 0.27 | 9.2 |
| 7# | 4.7 | 4.43 | 6.6 | 3.98 | 5.9 |
| 8# | 12.4 | 13.2 | 5.3 | 13.7 | 5.6 |
| 9# | 6.4 | 6.00 | 6.4 | 5.80 | 7.2 |
| 10# | 0.8 | 0.69 | 9.1 | 0.68 | 9.4 |
ND: “not detected”.
AFB1 analysis: TRFIA vs. HPLC methods.
| Number | AFB1 Result by HPLC µg·kg−1 | AFB1 Result by TRFIA µg·kg−1 |
|---|---|---|
| 1# | 5.20 | 4.90 |
| 2# | 6.40 | 6.70 |
| 3# | 9.80 | 10.7 |
| 4# | 3.20 | 2.75 |
| 5# | 2.90 | 2.45 |
| 6# | 0.80 | 0.70 |
| 7# | 1.30 | 1.50 |
| 8# | 3.60 | 4.20 |
| 9# | 0.31 | 0.44 |
| 10# | 3.60 | 3.80 |