OBJECTIVE: This field study aimed to assess the noise reduction of hearing protection for individual workers, demonstrate the effectiveness of training on the level of protection achieved, and measure the time required to implement hearing protector fit testing in the workplace. DESIGN: The National Institute for Occupational Safety and Health (NIOSH) conducted field studies in Louisiana and Texas to test the performance of HPD Well-Fit. STUDY SAMPLE: Fit tests were performed on 126 inspectors and engineers working in the offshore oil industry. RESULTS: Workers were fit tested with the goal of achieving a 25-dB PAR. Less than half of the workers were achieving sufficient protection from their hearing protectors prior to NIOSH intervention and training; following re-fitting and re-training, over 85% of the workers achieved sufficient protection. Typical test times were 6-12 minutes. CONCLUSIONS: Fit testing of the workers' earplugs identified those workers who were and were not achieving the desired level of protection. Recommendations for other hearing protection solutions were made for workers who could not achieve the target PAR. The study demonstrates the need for individual hearing protector fit testing and addresses some of the barriers to implementation.
OBJECTIVE: This field study aimed to assess the noise reduction of hearing protection for individual workers, demonstrate the effectiveness of training on the level of protection achieved, and measure the time required to implement hearing protector fit testing in the workplace. DESIGN: The National Institute for Occupational Safety and Health (NIOSH) conducted field studies in Louisiana and Texas to test the performance of HPD Well-Fit. STUDY SAMPLE: Fit tests were performed on 126 inspectors and engineers working in the offshore oil industry. RESULTS: Workers were fit tested with the goal of achieving a 25-dB PAR. Less than half of the workers were achieving sufficient protection from their hearing protectors prior to NIOSH intervention and training; following re-fitting and re-training, over 85% of the workers achieved sufficient protection. Typical test times were 6-12 minutes. CONCLUSIONS: Fit testing of the workers' earplugs identified those workers who were and were not achieving the desired level of protection. Recommendations for other hearing protection solutions were made for workers who could not achieve the target PAR. The study demonstrates the need for individual hearing protector fit testing and addresses some of the barriers to implementation.
Authors: William J Murphy; John R Franks; Elliott H Berger; Alberto Behar; John G Casali; Christine Dixon-Ernst; Edward F Krieg; Ben T Mozo; Julia D Royster; Larry H Royster; Stephen D Simon; Carol Stephenson Journal: J Acoust Soc Am Date: 2004-01 Impact factor: 1.840
Authors: Nicholas Heyer; Thais C Morata; Lynne E Pinkerton; Scott E Brueck; Daniel Stancescu; Mary Prince Panaccio; Hyoshin Kim; J Stephen Sinclair; Martha A Waters; Cherie F Estill; John R Franks Journal: Occup Environ Med Date: 2010-11-07 Impact factor: 4.402
Authors: E H Berger; J R Franks; A Behar; J G Casali; C Dixon-Ernst; R W Kieper; C J Merry; B T Mozo; C W Nixon; D Ohlin; J D Royster; L H Royster Journal: J Acoust Soc Am Date: 1998-02 Impact factor: 1.840
Authors: Elizabeth A Masterson; James A Deddens; Christa L Themann; Stephen Bertke; Geoffrey M Calvert Journal: Am J Ind Med Date: 2015-02-17 Impact factor: 2.214
Authors: Paul A Schulte; Thomas R Cunningham; Leslie Nickels; Sarah Felknor; Rebecca Guerin; Fred Blosser; Chia-Chia Chang; Pietra Check; Donald Eggerth; Michael Flynn; Christy Forrester; David Hard; Heidi Hudson; Jennifer Lincoln; Lauralynn T McKernan; Preethi Pratap; Carol M Stephenson; Donna Van Bogaert; Lauren Menger-Ogle Journal: Am J Ind Med Date: 2017-10-09 Impact factor: 2.214
Authors: Wei Gong; Liangliang Zhao; Ling Li; Thais C Morata; Wei Qiu; Huiling Amy Feng; Baoli Zhu Journal: Int J Environ Res Public Health Date: 2021-07-05 Impact factor: 3.390