Literature DB >> 36203859

Hybrid tracer - A modified novel extra oral tracer.

Nithin Kumar Sonnahalli1, Prajna P Shetty2, Ramesh Chowdhary2.   

Abstract

Introduction: Gothic arch Tracing has been a common modality in the recording of centric jaw relation. There has been two ways of recording the gothic tracing. They are extra oral and intra oral tracing. Among the extra oral tracers hight tracers are the most used tracers. Aim: Intra-oral and extra-oral tracers have a number of individual advantages and limitations. With the idea to overcome the short comings of both the tracers, hybrid tracers were made. Hybrid tracers could be a good alternative to the Hight-tracer in recording centric relation and can provide better clinical and teaching experience to the students. Methodology: The hybrid tracer is a two-component assembly, upper and lower component. The upper component has a central bearing plate and stylus in continuation with the central bearing plate. The lower component has central bearing device with three central bearing points one anteriorly and two posteriorly, and it has a tracing platform (15 × 35 mm) in continuation with the central bearing device. The length of these upper and lower components ismade to confine within the incisal rod of semi adjustable articulator. Result: hybrid tracers showed more accuracy while recording the centric jaw relation. There was more stability and equalization of pressure during the movement due to a tripod effect of three screws. Hence it provided more precise recording and being less technique sensitive. It was also more comfortable and acceptable by the patient.
Conclusion: hybrid tracers hence will provide more accuracy and precision in recording of horizontal jaw relation. This will in turn help in fabricating a successful prosthesis and enhance the well-being of the patient. This tracer will also be significant in institutions for educational purpose. Clinical implication: Hybrid tracers are simple, non-technique sensitive, provide balance, equalization of pressure, stabilize the occlusal rims well, are close to the centre of rotation providing precise record and provide easy access and visibility to the operator which will help the operator in guiding the patient well for a correct jaw relation.
© 2022 Craniofacial Research Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Equalization of pressure; Extra oral tracer; Gothic arch tracing; Hight tracer; Horizontal jaw relation

Year:  2022        PMID: 36203859      PMCID: PMC9530952          DOI: 10.1016/j.jobcr.2022.09.013

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  8 in total

Review 1.  An appraisal of the literature on centric relation. Part III.

Authors:  A Keshvad; R B Winstanley
Journal:  J Oral Rehabil       Date:  2001-01       Impact factor: 3.837

2.  The influence of different registration techniques on condyle displacement and electromyographic activity in stomatognathically healthy subjects: a prospective study.

Authors:  Sabine S Linsen; Helmut Stark; Azadeh Samai
Journal:  J Prosthet Dent       Date:  2012-01       Impact factor: 3.426

3.  The magic slate as recording medium for Gothic arch tracing.

Authors:  Ashwin R Mysore; Meena A Aras
Journal:  J Prosthet Dent       Date:  2012-07       Impact factor: 3.426

4.  Use of personal computers for Gothic arch tracing: analysis and evaluation of horizontal mandibular positions with edentulous prosthesis.

Authors:  Y Watanabe
Journal:  J Prosthet Dent       Date:  1999-11       Impact factor: 3.426

5.  Factors influencing centric relation records in edentulous mouths. 1964.

Authors:  A Albert Yurkstas; Krishan K Kapur
Journal:  J Prosthet Dent       Date:  2005-04       Impact factor: 3.426

6.  A comparative evaluation of static and functional methods for recording centric relation and condylar guidance: a clinical study.

Authors:  Mridul Thakur; Veena Jain; Hari Parkash; Pravesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-07-27

7.  The value of the Gothic arch tracing in the positioning of denture teeth.

Authors:  A S el-Gheriani; R B Winstanley
Journal:  J Oral Rehabil       Date:  1988-07       Impact factor: 3.837

8.  Evaluation of Four Elastomeric Interocclusal Recording Materials.

Authors:  P Dua; S H Gupta; S Ramachandran; H S Sandhu
Journal:  Med J Armed Forces India       Date:  2011-07-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.