| Literature DB >> 27401670 |
Igor P Oscorbin1,2, Ekaterina A Belousova1, Aleksandr I Zakabunin1, Ulyana A Boyarskikh1, Maksim L Filipenko1,2.
Abstract
Real-time or quantitative loop-mediated isothermal amplification (qLAMP) is a promising technique for the accurate detection of pathogens in organisms and the environment. Here we present a comparative study of the performance of six fluorescent intercalating dyes-SYTO-9, SYTO-13, SYTO-82, SYBR Green I, SYBR Gold, EvaGreen-in three different qLAMP model systems. SYTO-9 and SYTO-82, which had the best results, were used for additional enzyme and template titration studies. SYTO-82 demonstrated the best combination of time-to-threshold (Tt) and signal-to-noise ratio (SNR).Entities:
Keywords: Bst DNA polymerase; EvaGreen; LAMP; SYBR Gold; SYBR Green I; SYTO-13; SYTO-82; SYTO-9; isothermal amplification
Mesh:
Substances:
Year: 2016 PMID: 27401670 DOI: 10.2144/000114432
Source DB: PubMed Journal: Biotechniques ISSN: 0736-6205 Impact factor: 1.993