Literature DB >> 27376596

Microelectrode Arrays of Diamond-Insulated Graphitic Channels for Real-Time Detection of Exocytotic Events from Cultured Chromaffin Cells and Slices of Adrenal Glands.

Federico Picollo1,2,3,4, Alfio Battiato1,2,3,4, Ettore Bernardi1,2,3,4, Andrea Marcantoni3,4,5, Alberto Pasquarelli6, Emilio Carbone3,4,5, Paolo Olivero1,2,3,4, Valentina Carabelli3,4,5.   

Abstract

A microstructured graphitic 4 × 4 multielectrode array was embedded in a single-crystal diamond substrate (4 × 4 μG-SCD MEA) for real-time monitoring of exocytotic events from cultured chromaffin cells and adrenal slices. The current approach relies on the development of a parallel ion beam lithographic technique, which assures the time-effective fabrication of extended arrays with reproducible electrode dimensions. The reported device is suitable for performing amperometric and voltammetric recordings with high sensitivity and temporal resolution, by simultaneously acquiring data from 16 rectangularly shaped microelectrodes (20 × 3.5 μm(2)) separated by 200 μm gaps. Taking advantage of the array geometry we addressed the following specific issues: (i) detect both the spontaneous and KCl-evoked secretion simultaneously from several chromaffin cells directly cultured on the device surface, (ii) resolve the waveform of different subsets of exocytotic events, and (iii) monitoring quantal secretory events from thin slices of the adrenal gland. The frequency of spontaneous release was low (0.12 and 0.3 Hz, respectively, for adrenal slices and cultured cells) and increased up to 0.9 Hz after stimulation with 30 mM KCl in cultured cells. The spike amplitude as well as rise and decay time were comparable with those measured by carbon fiber microelectrodes and allowed to identify three different subsets of secretory events associated with "full fusion" events, "kiss-and-run" and "kiss-and-stay" exocytosis, confirming that the device has adequate sensitivity and time resolution for real-time recordings. The device offers the significant advantage of shortening the time to collect data by allowing simultaneous recordings from cell populations either in primary cell cultures or in intact tissues.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27376596     DOI: 10.1021/acs.analchem.5b04449

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Low pHo boosts burst firing and catecholamine release by blocking TASK-1 and BK channels while preserving Cav1 channels in mouse chromaffin cells.

Authors:  Laura Guarina; David H F Vandael; Valentina Carabelli; Emilio Carbone
Journal:  J Physiol       Date:  2017-03-02       Impact factor: 5.182

Review 2.  Electrochemical measurement of quantal exocytosis using microchips.

Authors:  Kevin D Gillis; Xin A Liu; Andrea Marcantoni; Valentina Carabelli
Journal:  Pflugers Arch       Date:  2017-09-02       Impact factor: 3.657

Review 3.  Surface-modified CMOS IC electrochemical sensor array targeting single chromaffin cells for highly parallel amperometry measurements.

Authors:  Meng Huang; Joannalyn B Delacruz; John C Ruelas; Shailendra S Rathore; Manfred Lindau
Journal:  Pflugers Arch       Date:  2017-09-09       Impact factor: 3.657

Review 4.  Recent Progress in Quantitatively Monitoring Vesicular Neurotransmitter Release and Storage With Micro/Nanoelectrodes.

Authors:  Yuying Liu; Jinchang Du; Mengying Wang; Jing Zhang; Chunlan Liu; Xianchan Li
Journal:  Front Chem       Date:  2021-01-11       Impact factor: 5.221

5.  On-Chip Cyclic Voltammetry Measurements Using a Compact 1024-Electrode CMOS IC.

Authors:  Meng Huang; Carlos I Dorta-Quiñones; Bradley A Minch; Manfred Lindau
Journal:  Anal Chem       Date:  2021-05-26       Impact factor: 8.008

Review 6.  Latest Trends in Electrochemical Sensors for Neurotransmitters: A Review.

Authors:  Zahra Tavakolian-Ardakani; Oana Hosu; Cecilia Cristea; Mohammad Mazloum-Ardakani; Giovanna Marrazza
Journal:  Sensors (Basel)       Date:  2019-04-30       Impact factor: 3.576

Review 7.  Advanced real-time recordings of neuronal activity with tailored patch pipettes, diamond multi-electrode arrays and electrochromic voltage-sensitive dyes.

Authors:  Bernd Kuhn; Federico Picollo; Valentina Carabelli; Giorgio Rispoli
Journal:  Pflugers Arch       Date:  2020-10-13       Impact factor: 3.657

8.  Triggering Neurotransmitters Secretion from Single Cells by X-ray Nanobeam Irradiation.

Authors:  Federico Picollo; Giulia Tomagra; Valentina Bonino; Valentina Carabelli; Lorenzo Mino; Paolo Olivero; Alberto Pasquarelli; Marco Truccato
Journal:  Nano Lett       Date:  2020-04-03       Impact factor: 11.189

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.