Literature DB >> 27376018

Methods, units and quality requirements for the analysis of haemoglobin A1c in diabetes mellitus.

Ilkka Penttilä1, Karri Penttilä1, Päivi Holm1, Harri Laitinen1, Päivi Ranta1, Jukka Törrönen1, Rainer Rauramaa1.   

Abstract

The formation of glycohemoglobin, especially the hemoglobin A1c (HbA1c) fraction, occurs when glucose becomes coupled with the amino acid valine in the β-chain of Hb; this reaction is dependent on the plasma concentration of glucose. Since the early 1970s it has been known that diabetics display higher values OF HbA1C because they have elevated blood glucose concentrations. Thus HbA1c has acquired a very important role in the treatment and diagnosis of diabetes mellitus. After the introduction of the first quantitative measurement OF HbA1C, numerous methods for glycohemoglobin have been introduced with different assay principles: From a simple mini-column technique to the very accurate automated high-pressure chromatography and lastly to many automated immunochemical or enzymatic assays. In early days, the results of the quality control reports for HbA1c varied extensively between laboratories, therefore in United States and Canada working groups (WG) of the Diabetes Controls and Complications Trial (DCCT) were set up to standardize the HbA1c assays against the DCCT/National Glycohemoglobin Standardization Program reference method based on liquid chromatography. In the 1990s, the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) appointed a new WG to plan a reference preparation and method for the HBA1c measurement. When the reference procedures were established, in 2004 IFCC recommended that all manufacturers for equipment used in HbA1c assays should calibrate their methods to their proposals. This led to an improvement in the coefficient of variation (CV%) associated with the assay. In this review, we describe the glycation of Hb, methods, standardization of the HbA1c assays, analytical problems, problems with the units in which HbA1c values are expressed, reference values, quality control aspects, target requirements for HbA1c, and the relationship of the plasma glucose values to HbA1c concentrations. We also note that the acceptance of the mmol/mol system for HbA1c as recommended by IFCC, i.e., the new unit and reference ranges, are becoming only slowly accepted outside of Europe where it seems that expressing HbA1c values either only in per cent units or with parallel reporting of percent and mmol/mol will continue. We believe that these issues should be resolved in the future and that it would avoid confusion if mmol/mol unit for HbA1c were to gain worldwide acceptance.

Entities:  

Keywords:  Diabetes; Glucose; Glycohemoglobin; Hemoglobin A1c; International Federation of Clinical Chemistry and Laboratory Medicine; Quality assurance; Recommendation; Reference values; Target limits

Year:  2016        PMID: 27376018      PMCID: PMC4921944          DOI: 10.5662/wjm.v6.i2.133

Source DB:  PubMed          Journal:  World J Methodol        ISSN: 2222-0682


  60 in total

1.  New hemoglobin in normal adult blood.

Authors:  H G KUNKEL; G WALLENIUS
Journal:  Science       Date:  1955-08-12       Impact factor: 47.728

2.  2013 Update on the worldwide standardization of the hemoglobin A1c measurement.

Authors:  Ragnar Hanas; W Garry John
Journal:  Pediatr Diabetes       Date:  2013-05-20       Impact factor: 4.866

3.  [HbA1c--new standardization introduced in Sweden. The new unit is mmol/mol].

Authors:  Mona Landin-Olsson; Jan-Olof Jeppsson; Gunnar Nordin
Journal:  Lakartidningen       Date:  2010-12-22

4.  Evaluation of the Menarini/ARKRAY ADAMS A1c HA-8180V analyser for HbA1c.

Authors:  Cas Weykamp; Erna Lenters-Westra; Hans van der Vuurst; Robbert Slingerland; Carla Siebelder; Willeke Visser-Dekkers
Journal:  Clin Chem Lab Med       Date:  2011-02-17       Impact factor: 3.694

5.  Recommendations for the implementation of international standardization of glycated hemoglobin in Italy.

Authors:  Andrea Mosca; Maria Teresa Branca; Mariarosa Carta; Maria Ludovica Genna; Carlo B Giorda; Rosangela Ghidelli; Germana Ghislandi; Dario Iafusco; Annunziata Lapolla; Vera Buondonno Lombardi; Carlo Augusto Lovagnini Scher; Maurizio Marra; Gerardo Medea; Franco Meschi; Andrea Pizzini; Francesco Rossi; Raffaele Scalpone; Gianni Tofini; Mariella Trovati; Martina Zaninotto
Journal:  Clin Chem Lab Med       Date:  2010-05       Impact factor: 3.694

6.  Adaptation of the Diazyme Direct Enzymatic HbA1c Assay for a microplate reader at room temperature.

Authors:  Ilkka Penttilä; Karri Penttilä; Toivo Halonen; Kari Pulkki; Jukka Törrönen; Rainer Rauramaa
Journal:  Clin Chem Lab Med       Date:  2011-05-17       Impact factor: 3.694

7.  Changing from glucose to HbA1c for diabetes diagnosis: predictive values of one test and importance of analytical bias and imprecision.

Authors:  Aneta Aleksandra Nielsen; Per Hyltoft Petersen; Anders Green; Cramer Christensen; Henry Christensen; Ivan Brandslund
Journal:  Clin Chem Lab Med       Date:  2014-07       Impact factor: 3.694

8.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Clin Chem       Date:  2011-05-26       Impact factor: 8.327

9.  Insulin sensitivity indices obtained from oral glucose tolerance testing: comparison with the euglycemic insulin clamp.

Authors:  M Matsuda; R A DeFronzo
Journal:  Diabetes Care       Date:  1999-09       Impact factor: 19.112

10.  Impaired glucose metabolism among those with and without diagnosed diabetes and mortality: a cohort study using Health Survey for England data.

Authors:  Vanessa L Z Gordon-Dseagu; Jennifer S Mindell; Andrew Steptoe; Alison Moody; Jane Wardle; Panayotes Demakakos; Nicola J Shelton
Journal:  PLoS One       Date:  2015-03-18       Impact factor: 3.240

View more
  4 in total

1.  Effects of hemoglobin variants HbJ Bangkok, HbE, HbG Taipei, and HbH on analysis of glycated hemoglobin via ion-exchange high-performance liquid chromatography.

Authors:  Xiu-Ming Zhang; Dong-Mei Wen; Sheng-Nan Xu; Ming-Huan Suo; Ya-Qiong Chen
Journal:  J Clin Lab Anal       Date:  2017-04-13       Impact factor: 2.352

2.  Advanced glycation end-products (AGEs) are lower in prostate tumor tissue and inversely related to proportion of West African ancestry.

Authors:  Morgan L Zenner; Yves B Helou; Ryan J Deaton; Maria Sverdlov; Heng Wang; Andre Kajdacsy-Balla; Virgilia Macias; Cindy Voisine; Marcus Murray; Sarki A Abdulkadir; Adam B Murphy; Larisa Nonn
Journal:  Prostate       Date:  2021-12-02       Impact factor: 4.104

3.  Association of Glycated Haemoglobin and Serum Apolipoproteins with Diabetic Retinopathy: An Indian Overview.

Authors:  Bhasker Mukherjee; Sandeep Shankar; Rehan Ahmed; Kanchan Singh; Kapil Bhatia
Journal:  J Clin Diagn Res       Date:  2017-09-01

4.  Trehalose Activates Hepatic and Myocardial Autophagy and Has Anti-Inflammatory Effects in db/db Diabetic Mice.

Authors:  Tatiana A Korolenko; Marina V Ovsyukova; Nataliya P Bgatova; Igor D Ivanov; Svetlana I Makarova; Valentin A Vavilin; Alexey V Popov; Ekaterina I Yuzhik; Elena V Koldysheva; Erik C Korolenko; Evgeny L Zavjalov; Tamara G Amstislavskaya
Journal:  Life (Basel)       Date:  2022-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.