| Literature DB >> 27375687 |
Tariq Abduljabbar1, Mohammed Ayedh AlQahtani2, Zaid Al Jeaidi3, Fahim Vohra4.
Abstract
OBJECTIVES: To evaluate the effect of silane application and silane heat treatment on lithium-disilicate ceramic when bonded to composite resin.Entities:
Keywords: Lithium disilicate; Microtensile bond strength; Silane; Silane heat treatment
Year: 2016 PMID: 27375687 PMCID: PMC4928396 DOI: 10.12669/pjms.323.9851
Source DB: PubMed Journal: Pak J Med Sci ISSN: 1681-715X Impact factor: 1.088
Comparison of means and standard deviations of micro tensile bond strength of experimental groups using ANOVA.
| Lithium disilicate ceramic (µtbs) | Mean | 34.95 | 39.94 | 42.63 | < 0.01[ |
| SD | 3.123 | 2.589 | 3.701 | ||
significant,
Analysis of variance (ANOVA) was performed
SD: Standard deviation, µtbs: Microtensile bond strength.
Fig.1Example of category 2 failure propagating into resin at x214 magnification (Specimen from group C).
Fig.2Example of category 1 failure at x1000 magnification (Specimen from group A).
Percentage distribution of failure modes in the experimental groups.
| Category 1 | 100 | 50 | 25 |
| Category 2 | 0 | 50 | 75 |
| Category 3 | 0 | 0 | 0 |
| Category 4 | 0 | 0 | 0 |
| Appendix A: Materials and Equipment Used |
|---|
| E-max Press® (E): (lithium disilicate ceramic, Ivoclar Vivadent, MO2 lot no. 4312 |
| 9.5% Hydroflouric acid: Ceram Etch, Gresco product Int |
| Silane (S): Calibra, Silane Coupling Agent, Dentsply, Caulk. Lot no.070307) |
| Composite Blocks And luting agent: Filtek Z350 XT, Hybrid filler particles, Universal Restorative, 3M ESPE, Shade A1E, Lot no. 8CU |
| Aquasil soft putty: Polyvinylsiloxane impression material, Caulk, Dentsply |
| Cyanoacrylate adhesive: Zapit, Dental ventures Inc, CA, USA |
| Curing light: Bluephase ® C8, Ivoclar Vivadent, AG, Schaan / Liechtenstein |
| Hot pressing furnaces: Multimat 2 (Dentsply) and Programat P300 (Ivoclar Vivadent, AG, Schaan / Liechtenstein) |
| SiC abrasive coated paper & Aluminutesa: Mark V Laboratory, East Granby, CT, USA |
| Isomet 1000: Buehler, Lake Bluff, IL, USA |
| Microtensile tester: Bisco Inc., Virginia, USA. |
| Scanning electron microscope: XL 30CP, Phillips |