Literature DB >> 27374639

Femoral Component Rotation in Total Knee Arthroplasty: A Comparison Between Transepicondylar Axis and Posterior Condylar Line Referencing.

Vincenzo Franceschini1, Scott R Nodzo1, Alejandro Gonzalez Della Valle1.   

Abstract

BACKGROUND: Proper rotational alignment of the femoral component is critical for a successful total knee arthroplasty (TKA). Controversy remains regarding the optimal intraoperative reference to determine femoral component rotation.
METHODS: Thirty-one patients who underwent magnetic resonance imaging of a TKA between April 2008 and November 2015 were retrospectively reviewed. A single surgeon performed the TKA using a posterior condylar angle of 3° (PCA group) or surgical transepicondylar axis (TEA group) to determine femoral component rotation. The hip-knee-ankle angle and the tibial plateau-tibial shaft angle (TPTSA) were measured on full-length x-rays, and the rotation of the femoral component was measured as compared to the TEA on magnetic resonance imaging (negative values indicate internal rotation).
RESULTS: The median measured rotational deviation of the femoral component from the TEA was significantly higher in the PCA group than in the TEA group (-3.8 ± 2.9° and -1.4 ± 1.9°, respectively) (P = .02). When knees with preoperative varus and neutral alignment were evaluated, the median measured rotational deviation of the femoral component was significantly higher in the fixed PCL group than in the TEA group (-3.4 ± 3.3° and -0.61 ± 1.3°, respectively) (P = .04). Linear regression used to evaluate the relationship between the TPTSA and femoral component rotational deviation from the TEA revealed similar near zero slopes (P = .90); however, the Y intercepts in the TEA group were significantly higher than the PCA group (-2.8 ± 0.7 and -5.5 ± 1.1, respectively) (P = .007).
CONCLUSION: The use of the surgical TEA as an intraoperative rotational reference is more reliable than the PCA in valgus, varus, and neutrally aligned knees independent from the magnitude of the TPTSA.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  femoral rotation; posterior condylar angle; total knee arthroplasty; total knee arthroplasty balance; transepicondylar axis

Mesh:

Year:  2016        PMID: 27374639     DOI: 10.1016/j.arth.2016.05.032

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  Failure modes in malrotated total knee replacement.

Authors:  Ashok Rajgopal; Paneendra Sudarshan; Sumit Kumar; Kalpana Aggarwal
Journal:  Arch Orthop Trauma Surg       Date:  2022-08-03       Impact factor: 2.928

2.  No correlation between rotation of femoral components in the transverse plane and clinical outcome after total knee arthroplasty.

Authors:  Roland Becker; Katharina Bäker; Hagen Hommel; Manfred Bernard; Sebastian Kopf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-05-16       Impact factor: 4.342

3.  The flexion space is more reliably balanced when using the transepicondylar axis as compared to the posterior condylar line.

Authors:  Scott R Nodzo; Vincenzo Franceschini; Diego Sanchez Cruz; Alejandro Gonzalez Della Valle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-02-07       Impact factor: 4.342

4.  Evaluating distal femoral torsion and posterior condylar line reliability for adjusting femoral component rotation in TKA, Egyptian population radiographic study.

Authors:  Mohamed A Mahran; Ahmed A Khalifa; Moataz Abdelraheem Ahmed; Hatem M Bakr; Yaser E Khalifa
Journal:  J Clin Orthop Trauma       Date:  2020-12-05

5.  Patient-specific instrumentation combined with a new tool for gap balancing is useful in total knee replacement: a 3-year follow-up of a retrospective study.

Authors:  Ting Deng; Tangyou Liu; Qing Lei; Lihong Cai; Song Chen
Journal:  J Orthop Surg Res       Date:  2021-05-12       Impact factor: 2.359

6.  A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images.

Authors:  Emma L Robertson; Martin Hengherr; Felix Amsler; Michael T Hirschmann; Dominic T Mathis
Journal:  Skeletal Radiol       Date:  2021-01-04       Impact factor: 2.199

7.  Tibiofemoral rotation alignment in the normal knee joints among Chinese adults: a CT analysis.

Authors:  Yufeng Lu; Xiaoyu Ren; Benyin Liu; Peng Xu; Yangquan Hao
Journal:  BMC Musculoskelet Disord       Date:  2020-05-23       Impact factor: 2.362

8.  Gait Analysis after Total Knee Arthroplasty Assisted by 3D-Printed Personalized Guide.

Authors:  Maolin Sun; Ying Zhang; Yang Peng; Dejie Fu; Huaquan Fan; Rui He
Journal:  Biomed Res Int       Date:  2020-06-30       Impact factor: 3.411

9.  Does increased femoral component size options reduce anterior femoral notching in total knee replacement?

Authors:  Anshu Shekhar; Ch Chandra Krishna; Shantanu Patil; Sachin Tapasvi
Journal:  J Clin Orthop Trauma       Date:  2019-03-16

10.  [Effect of three-dimensional printing guide plate on improving femoral rotational alignment and patellar tracking in total knee arthroplasty].

Authors:  Maolin Sun; Liu Yang; Rui He; Peng Hao; Jiawei Sun
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-03-15
View more