Literature DB >> 32189945

Does increased femoral component size options reduce anterior femoral notching in total knee replacement?

Anshu Shekhar1, Ch Chandra Krishna1, Shantanu Patil2, Sachin Tapasvi1.   

Abstract

OBJECTIVE: Total knee arthroplasty (TKA) is currently the best option for management of advanced knee arthritis for patients who have exhausted conservative management. There have been significant implant design improvements and this is a continuing process to help the surgeon replicate patient anatomy and kinematics. Amongst the many variables in implantation to achieve a well-functioning TKA, getting optimal femoral component sizing is one. Every implant system has certain discreet implant sizes and the surgeon has to strive to obtain the best fit possible for the patient and attain a well aligned and stable TKA. The aim of this study was to assess the frequency of various femoral component sizes being implanted with a system which has 2.5 mm antero-posterior increment between sizes, and to assess the incidence of anterior femoral notching when using a posterior referencing system.
MATERIALS AND METHODS: A retrospective analysis of 739 TKAs implanted in 532 patients between January 2013 and January 2016 at a single center using a single posterior stabilized implant system was done. Patient demographics and femur component size used was obtained from hospital patient records. Immediate post-operative radiographs were analyzed to look for anterior femoral notching and presence of this was classified according to Tayside classification. A telephonic follow up at minimum 2 tears post-surgery was done to interview for occurrence of supracondylar femur fracture or revision for any other causes.
RESULTS: There were 207 bilateral and 325 unilateral TKAs performed in 532 patients during the study period. There were 245 males and 287 females with an average age of 61.3 years (43-81 years, SD = 7.2). The most commonly used femoral component was 60 mm and an intermediate size prosthesis was used in 43.11% patients. The incidence of femoral notching ranged from 0 to 6.3%. No patient had sustained a supracondylar condylar fracture at minimum 2 years follow up.
CONCLUSION: The availability of a larger number of femoral components in a TKA system allows the surgeon the modularity to choose and obtain the best fit possible. Restoration of posterior condylar offset, preventing anterior notching, medio-lateral overhang and patellofemoral joint stuffing are greatly dependent on correct femoral component sizing. The findings from our study underscore the need to use an implant system with as many femoral size options as possible with lesser increments in between sizes to minimize anterior femoral notching when using a posterior referencing technique.
© 2019 Delhi Orthopedic Association. All rights reserved.

Entities:  

Keywords:  Arthroplasty; Component; Femur; Fitting; Knee; Prosthesis; Replacement; Treatment outcome

Year:  2019        PMID: 32189945      PMCID: PMC7068002          DOI: 10.1016/j.jcot.2019.03.006

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  25 in total

1.  Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty. Influence of posterior condylar offset.

Authors:  J Bellemans; S Banks; J Victor; H Vandenneucker; A Moemans
Journal:  J Bone Joint Surg Br       Date:  2002-01

Review 2.  Technical considerations in total knee surgery. Management of patella problems.

Authors:  V M Goldberg; H E Figgie; M P Figgie
Journal:  Orthop Clin North Am       Date:  1989-04       Impact factor: 2.472

3.  Effects of patellofemoral overstuffing on knee flexion and patellar kinematics following total knee arthroplasty: a cadaveric study.

Authors:  Daniel N Bracey; Matthew L Brown; Hoyt R Beard; Sandeep Mannava; Omar F Nazir; Thorsten M Seyler; Jason E Lang
Journal:  Int Orthop       Date:  2015-03-18       Impact factor: 3.075

4.  Total knee arthroplasty and the unforeseen impact on return to work: a cross-sectional multicenter survey.

Authors:  Arthur J Kievit; Rutger C I van Geenen; P Paul F M Kuijer; Thijs M J Pahlplatz; Leendert Blankevoort; Matthias U Schafroth
Journal:  J Arthroplasty       Date:  2014-01-10       Impact factor: 4.757

Review 5.  Femoral Component Sizing During Total Knee Arthroplasty: Anterior Versus Posterior Referencing.

Authors:  Ryan S Charette; Neil P Sheth; Friedrich Boettner; Giles R Scuderi; Christopher M Melnic
Journal:  JBJS Rev       Date:  2018-01

6.  The consequences of anterior femoral notching in total knee arthroplasty. A biomechanical study.

Authors:  M L Lesh; D J Schneider; G Deol; B Davis; C R Jacobs; V D Pellegrini
Journal:  J Bone Joint Surg Am       Date:  2000-08       Impact factor: 5.284

7.  Gender-based differences in the dimensions of the femoral trochlea and condyles in the Chinese population: correlation to the risk of femoral component overhang.

Authors:  Mengning Yan; Jun Wang; You Wang; Jun Zhang; Bing Yue; Yiming Zeng
Journal:  Knee       Date:  2012-12-12       Impact factor: 2.199

8.  Effect of the Referencing System on the Posterior Condylar Offset and Anterior Flange-Bone Contact in Posterior Cruciate-Substituting Total Knee Arthroplasty.

Authors:  O-Sung Lee; Yong Seuk Lee
Journal:  J Arthroplasty       Date:  2017-11-16       Impact factor: 4.757

9.  Anterior femoral notching and ipsilateral supracondylar femur fracture in total knee arthroplasty.

Authors:  M A Ritter; P M Faris; E M Keating
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

10.  Risk of periprosthetic fracture after anterior femoral notching.

Authors:  Narendra Gujarathi; Amit B Putti; Rami J Abboud; James G B MacLean; Arthur J Espley; Catherine F Kellett
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

View more
  3 in total

1.  [Research progress of anterior femoral notching in total knee arthroplasty].

Authors:  Jincheng Zhang; Shuo Feng; Leshu Zhang; Hang Zhou; Xiangyang Chen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-11-15

Review 2.  Anterior femoral notching ≥ 3 mm is associated with increased risk for supracondylar periprosthetic femoral fracture after total knee arthroplasty: a systematic review and meta-analysis.

Authors:  Dimitrios Stamiris; Nifon K Gkekas; Konstantinos Asteriadis; Stavros Stamiris; Panagiotis Anagnostis; Lazaros Poultsides; Ioannis Sarris; Michael Potoupnis; Eustathios Kenanidis; Eleftherios Tsiridis
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-04-26

3.  Stress distribution patterns during the gait cycle in patients with anterior femoral notching following total knee replacement.

Authors:  Jin-Cheng Zhang; Le-Shu Zhang; Hang Zhou; Wang Chen; Zheng-Hao Hu; Xiang-Yang Chen; Shuo Feng
Journal:  BMC Musculoskelet Disord       Date:  2022-07-28       Impact factor: 2.562

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.