Literature DB >> 27365787

A comparative evaluation of rate of space closure after extraction using E-chain and stretched modules in bimaxillary dentoalveolar protrusion cases.

Rajat Mitra1, S M Londhe2, Prasanna Kumar3.   

Abstract

BACKGROUND: Aim of this study was to compare the rate of space closure between E-chain mechanics in one side of upper arch and by elastomeric module with ligature wire on the contralateral side in same patient.
METHODS: Thirty bimaxillary dentoalveolar protrusion cases were taken up for comprehensive fixed orthodontic treatment after extraction of all first premolars to retract both upper and lower anterior teeth. After initial alignment and levelling, alginate impressions were made for upper and lower arches and models constructed. In the upper arch model a vernier caliper was used to measure the extraction space in both sides from middle point of distal surface of canine to the middle most point of mesial surface of second premolar. This is the amount of space present before the onset of retraction mechanics. During space closure procedure two different retracting components were applied in right and left sides of each case. On right side elastic chain (E-chain) applied in both upper and lower arches and on left side elastomeric module with steel ligature (0.010") stretched double its diameter fixed in both arches. Both the mechanisms produced approximately 250-300 g of force as measured by a tension gauge. After onset of retraction mechanism all patients were recalled after every six weeks for three visits. In all these three visits modules and E-chains were changed. In all three visits impression was made, models constructed, and the remaining available space was measured by a vernier caliper up to 0.1 mm level variations.
RESULTS: Mean value for total space closure in case of E-chain was 2.777 mm whereas in case of module with ligature wire the value increased to 3.017 mm. Mean value for rate of space closure in case of E-chain was 0.2143 mm, whereas in case of module with ligature wire the value increased to 0.2343 mm with a standard deviation of 0.001104 and 0.001194, respectively. The standard deviation for total space closure was 0.1305 for E-chain and 0.1487 for module with ligature wire.
CONCLUSION: Space closure by elastomeric module with ligature wire is better than the E-chain.

Entities:  

Keywords:  bimaxillary dentoalveolar protrusion; elastic chain; elastomeric module with ligature

Year:  2011        PMID: 27365787      PMCID: PMC4920791          DOI: 10.1016/S0377-1237(11)60017-8

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  9 in total

1.  Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations.

Authors:  B P Loftus; J Artun; J I Nicholls; T A Alonzo; J A Stoner
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-09       Impact factor: 2.650

2.  An ex-vivo investigation into the effect of bracket displacement on the resistance to sliding.

Authors:  D O'Reilly; P A Dowling; L Lagerstrom; M L Swartz
Journal:  Br J Orthod       Date:  1999-09

3.  The effect of hydrogen ion concentration on the force-degradation rate of orthodontic polyurethane chain elastics.

Authors:  J P Ferriter; C E Meyers; L Lorton
Journal:  Am J Orthod Dentofacial Orthop       Date:  1990-11       Impact factor: 2.650

4.  Controlled space closure with a preadjusted appliance system.

Authors:  J C Bennett; R P McLaughlin
Journal:  J Clin Orthod       Date:  1990-04

5.  Frictional forces related to self-ligating brackets.

Authors:  L Pizzoni; G Ravnholt; B Melsen
Journal:  Eur J Orthod       Date:  1998-06       Impact factor: 3.075

6.  An investigation into the placement of force delivery systems and the initial forces applied by clinicians during space closure.

Authors:  C Nattrass; A J Ireland; M Sherriff
Journal:  Br J Orthod       Date:  1997-05

7.  Laboratory and intra-oral tests of the degradation of elastic chains.

Authors:  R Kuster; B Ingervall; W Bürgin
Journal:  Eur J Orthod       Date:  1986-08       Impact factor: 3.075

8.  A comparison of the rate of space closure using a nickel-titanium spring and an elastic module: a clinical study.

Authors:  R H Samuels; S J Rudge; L H Mair
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-05       Impact factor: 2.650

9.  The effect of environmental factors on elastomeric chain and nickel titanium coil springs.

Authors:  C Nattrass; A J Ireland; M Sherriff
Journal:  Eur J Orthod       Date:  1998-04       Impact factor: 3.075

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.