Literature DB >> 27348519

The association between home vs. ambulatory night-time blood pressure and end-organ damage in the general population.

Annika S Lindroos1, Jouni K Johansson, Pauli J Puukka, Ilkka Kantola, Veikko Salomaa, Eeva P Juhanoja, Sam S E Sivén, Pekka Jousilahti, Antti M Jula, Teemu J Niiranen.   

Abstract

OBJECTIVE: The aim of this study was to test the agreement between night-time home and night-time ambulatory blood pressure (BP) and to compare their associations with hypertensive end-organ damage for the first time in the general population.
METHODS: A population sample of 248 participants underwent measurements for night-time home BP (three measurements on two nights with a timer-equipped home device), night-time ambulatory BP, pulse wave velocity (PWV), carotid intima-media thickness (IMT) and echocardiographic left ventricular mass index (LVMI).
RESULTS: No significant or systematic differences were observed between mean night-time ambulatory and home BPs (systolic/diastolic difference: 0.7 ± 7.6/0.2 ± 6.0 mmHg, P = 0.16/0.64). All night-time home and ambulatory BPs were positively correlated with PWV, IMT and LVMI (P < 0.01 for all). No significant differences in Pearson's correlations between end-organ damage and night-time home or ambulatory BP were observed (P ≥ 0.11 for all comparisons using Dunn and Clark's Z), except for a slightly stronger correlation between PWV and ambulatory SBP than for home SBP (r = 0.57 vs. 0.50, P = 0.03). The adjusted R of all multivariable-adjusted models for PWV, IMT or LVMI that included night-time home or ambulatory SBP/DBP were within 2/1%.
CONCLUSION: Our study demonstrates that night-time home and ambulatory measurements produce similar BP values that have comparable associations with end-organ damage in the general population even when a clinically feasible measurement protocol is used for measuring night-time home BP. In the future, night-time home BP measurement may offer a feasible and easily accessible alternative to ambulatory monitoring for the measurement of night-time BP.

Entities:  

Mesh:

Year:  2016        PMID: 27348519     DOI: 10.1097/HJH.0000000000000995

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  8 in total

1.  Night-time blood pressure and pulse wave velocity in dialysis patients.

Authors:  Xiurong Li; Qingbo Jiang; Wenhui Wu; Xianlin Xu; Liying Miao; Lina Jin; Lina Xue; Tian Huang; Jia Di; Jinfeng Liu; Xiaozhou He
Journal:  Clin Exp Nephrol       Date:  2017-08-08       Impact factor: 2.801

Review 2.  KDOQI US Commentary on the 2017 ACC/AHA Hypertension Guideline.

Authors:  Holly J Kramer; Raymond R Townsend; Karen Griffin; Joseph T Flynn; Daniel E Weiner; Michael V Rocco; Michael J Choi; Matthew R Weir; Tara I Chang; Rajiv Agarwal; Srinivasan Beddhu
Journal:  Am J Kidney Dis       Date:  2019-04       Impact factor: 8.860

3.  Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9601T.

Authors:  Mitsuo Kuwabara; Kanako Harada; Yukiko Hishiki; Takayoshi Ohkubo; Kazuomi Kario; Yutaka Imai
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-05-24       Impact factor: 3.738

4.  Genome-wide association study of nocturnal blood pressure dipping in hypertensive patients.

Authors:  Jenni M Rimpelä; Ilkka H Pörsti; Antti Jula; Terho Lehtimäki; Teemu J Niiranen; Lasse Oikarinen; Kimmo Porthan; Antti Tikkakoski; Juha Virolainen; Kimmo K Kontula; Timo P Hiltunen
Journal:  BMC Med Genet       Date:  2018-07-04       Impact factor: 2.103

Review 5.  Clinical significance of nocturnal home blood pressure monitoring and nocturnal hypertension in Asia.

Authors:  Takeshi Fujiwara; Satoshi Hoshide; Naoko Tomitani; Hao-Min Cheng; Arieska Ann Soenarta; Yuda Turana; Chen-Huan Chen; Huynh Van Minh; Guru Prasad Sogunuru; Jam Chin Tay; Tzung-Dau Wang; Yook-Chin Chia; Narsingh Verma; Yan Li; Ji-Guang Wang; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2021-02-16       Impact factor: 3.738

6.  Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9600T.

Authors:  Mitsuo Kuwabara; Kanako Harada; Yukiko Hishiki; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-01-04       Impact factor: 3.738

7.  The relation of work-related factors with ambulatory blood pressure and nocturnal blood pressure dipping among aging workers.

Authors:  Saana Karelius; Jussi Vahtera; Jaana Pentti; Annika S Lindroos; Pekka Jousilahti; Olli J Heinonen; Sari Stenholm; Teemu J Niiranen
Journal:  Int Arch Occup Environ Health       Date:  2019-12-31       Impact factor: 3.015

8.  Comparison of nighttime measurement schedules using a wrist-type nocturnal home blood pressure monitoring device.

Authors:  Naoko Tomitani; Hiroshi Kanegae; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2021-03-16       Impact factor: 3.738

  8 in total