Literature DB >> 27329093

Late recurrence of a completely occluded large intracranial aneurysm treated with a Tubridge flow diverter.

Xiaoxi Zhang1, Nan Lv1, Chi Wang1, Wei Cao1, Jianmin Liu1, Qinghai Huang1.   

Abstract

We report a rare case of recurrence of a large intracavernous aneurysm after angiography proved complete occlusion. The aneurysm was treated by a combination of a Tubridge flow diverter and coils, and balloon angioplasty, after flow diverter devices deployment for parent vessel stenosis. Six month angiographic follow-up demonstrated complete occlusion. Unfortunately, obvious aneurysm recurrence was confirmed on 2 year angiographic follow-up. The probable mechanism of recurrence was analyzed. 2016 BMJ Publishing Group Ltd.

Entities:  

Keywords:  Aneurysm; Flow Diverter

Mesh:

Year:  2016        PMID: 27329093      PMCID: PMC4932404          DOI: 10.1136/bcr-2016-012268

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  16 in total

Review 1.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review.

Authors:  Francesco Briganti; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Arturo Brunetti; Francesco Maiuri
Journal:  Neuroradiol J       Date:  2015-08-27

Review 2.  Flow diverter stents in the treatment of intracranial aneurysms: Where are we?

Authors:  Laurent Pierot
Journal:  J Neuroradiol       Date:  2011-01-22       Impact factor: 3.447

3.  Treatment of intracranial aneurysms by flow diverter devices: long-term results from a single center.

Authors:  Francesco Briganti; Manuela Napoli; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Fabio Tortora; Francesco Maiuri
Journal:  Eur J Radiol       Date:  2014-06-02       Impact factor: 3.528

4.  Comparison of the flow diverter and stent-assisted coiling in large and giant aneurysms: safety and efficacy based on a propensity score-matched analysis.

Authors:  Yongxin Zhang; Yu Zhou; Pengfei Yang; Jianmin Liu; Yi Xu; Bo Hong; Wenyuan Zhao; Qi Chen; Qing-Hai Huang
Journal:  Eur Radiol       Date:  2015-10-15       Impact factor: 5.315

5.  In vitro reproduction of device deformation leading to thrombotic complications and failure of flow diversion.

Authors:  Laurent Estrade; Alina Makoyeva; Tim E Darsaut; Jimmy Ghostine; Evgueni Kouznetsov; Igor Salazkin; Daniel Roy; Alain Weill; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

6.  Long-Term Outcome of Tubridge Flow Diverter(S) in Treating Large Vertebral Artery Dissecting Aneurysms-A Pilot Study.

Authors:  Y-B Fang; W-L Wen; P-F Yang; Y Zhou; Y-N Wu; B Hong; Y Xu; W-Y Zhao; J-M Liu; Q-H Huang
Journal:  Clin Neuroradiol       Date:  2016-01-15       Impact factor: 3.649

7.  Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents.

Authors:  Angelo Carneiro; Neil Rane; Wilhelm Küker; Martino Cellerini; Rufus Corkill; James V Byrne
Journal:  Neuroradiology       Date:  2013-12-07       Impact factor: 2.804

8.  A novel flow-diverting device (Tubridge) for the treatment of 28 large or giant intracranial aneurysms: a single-center experience.

Authors:  Y Zhou; P-F Yang; Y-B Fang; Y Xu; B Hong; W-Y Zhao; Q Li; R Zhao; Q-H Huang; J-M Liu
Journal:  AJNR Am J Neuroradiol       Date:  2014-04-10       Impact factor: 3.825

9.  Aneurysm rupture after endovascular flow diversion: the possible role of persistent flows through the transition zone associated with device deformation.

Authors:  T E Darsaut; E Rayner-Hartley; A Makoyeva; I Salazkin; F Berthelet; J Raymond
Journal:  Interv Neuroradiol       Date:  2013-05-21       Impact factor: 1.610

Review 10.  Flow diverters for intracranial aneurysms.

Authors:  Yazan J Alderazi; Darshan Shastri; Tareq Kass-Hout; Charles J Prestigiacomo; Chirag D Gandhi
Journal:  Stroke Res Treat       Date:  2014-05-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.