Case report of an anomalous single azygos venous coil insertion to reduce the defibrillation threshold in a patient with a right-sided deltopectoral ICD implant.

Darragh Patrick Moran1, Usman Bhutta1, Ibrahim Yearoo1, Edward Keelan1, James O'Neill1, Joseph Galvin1.   

Abstract

Entities:  

Keywords:  Arrhythmias

Year:  2013        PMID: 27326066      PMCID: PMC4832637          DOI: 10.1136/heartasia-2012-010179

Source DB:  PubMed          Journal:  Heart Asia        ISSN: 1759-1104


× No keyword cloud information.
  8 in total

1.  Azygos vein lead implantation: a novel adjunctive technique for implantable cardioverter defibrillator placement.

Authors:  David Cesario; Mandeep Bhargava; Miguel Valderrábano; Gregg C Fonarow; Bruce Wilkoff; Kalyanam Shivkumar
Journal:  J Cardiovasc Electrophysiol       Date:  2004-07

2.  Hemiazygous coil placement for high-defibrillation thresholds in a patient with a right-sided implantable cardioverter defibrillator.

Authors:  Kent R Nilsson; Kevin P Jackson
Journal:  Pacing Clin Electrophysiol       Date:  2010-08-17       Impact factor: 1.976

3.  Azygous vein coil lowers defibrillation threshold in patients with high defibrillation threshold.

Authors:  Swee-Chong Seow; Clara Sy Tolentino; Jing Zhao; Toon-Wei Lim
Journal:  Europace       Date:  2011-03-23       Impact factor: 5.214

4.  Successful reduction of a high defibrillation threshold by a combined implantation of a subcutaneous array and azygos vein lead.

Authors:  Takumi Yamada; Peter G Robertson; H Thomas McElderry; Harish Doppalapudi; Vance J Plumb; G Neal Kay
Journal:  Pacing Clin Electrophysiol       Date:  2012-02-23       Impact factor: 1.976

5.  Coronary sinus shocking lead as salvage in patients with advanced CHF and high defibrillation thresholds.

Authors:  Osman Faheem; Arun Padala; Jeffrey Kluger; Steven Zweibel; Christopher A Clyne
Journal:  Pacing Clin Electrophysiol       Date:  2010-03-08       Impact factor: 1.976

6.  Defibrillation efficacy comparing a subcutaneous array electrode versus an "active can" implantable cardioverter defibrillator and a subcutaneous array electrode in addition to an "active can" implantable cardioverter defibrillator: results from active can versus array trials I and II.

Authors:  R Gradaus; M Block; K Seidl; J Brunn; F Isgro; D Hammel; B Hauer; G Breithardt; D Bocker
Journal:  J Cardiovasc Electrophysiol       Date:  2001-08

7.  The azygos defibrillator lead for elevated defibrillation thresholds: implant technique, lead stability, and patient series.

Authors:  Jonas A Cooper; Matthew P Latacha; Gabriel E Soto; Richard G Garmany; Marye J Gleva; Jane Chen; Mitchell N Faddis; Timothy W Smith
Journal:  Pacing Clin Electrophysiol       Date:  2008-11       Impact factor: 1.976

8.  Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.

Authors:  D S Echt; K Armstrong; P Schmidt; P E Oyer; E B Stinson; R A Winkle
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

  8 in total
  2 in total

1.  A Systematic Review and Single-center Experience of Azygos Vein Defibrillator Lead Insertion.

Authors:  Ying Chi Yang; Suchith Shetty; Ketan Koranne; Aaqib Malik; Michael Giudici
Journal:  J Innov Card Rhythm Manag       Date:  2022-05-15

2.  Transvenous lead implantation via the accessory hemiazygos vein in superior vena cava occlusion.

Authors:  Peter H Waddingham; Adam S C Dennis; Anu Balan; Anthony W C Chow
Journal:  Heart Rhythm O2       Date:  2021-12-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.