Literature DB >> 27312553

Discrepancies between Antigen and Polymerase Chain Reaction Tests for the Detection of Rotavirus and Norovirus.

Hyun Soo Kim1, Jae-Seok Kim2.   

Abstract

We compared the results of an antigen test (ELISA) with those of polymerase chain reaction (PCR) for the detection of rotavirus and norovirus in stool specimens. Rotavirus and norovirus antigen-positive stool specimens were collected, and rotavirus and norovirus PCRs were performed on these specimens. Of the 325 rotavirus antigen-positive specimens, 200 were positive for both assays and 125 were PCR negative. Of 286 norovirus antigen-positive specimens, 51 were PCR negative. Comparison of the lower limit of detection showed that rotavirus PCR was 16 times more sensitive and norovirus PCR was over 4,000 times more sensitive than the ELISA. Discrepant results between ELISA and PCR were common, and the possibility of false-positive and false-negative results should be considered with rotavirus and norovirus assays.
© 2016 by the Association of Clinical Scientists, Inc.

Keywords:  ELISA; PCR; comparison; norovirus; rotavirus

Mesh:

Substances:

Year:  2016        PMID: 27312553

Source DB:  PubMed          Journal:  Ann Clin Lab Sci        ISSN: 0091-7370            Impact factor:   1.256


  4 in total

1.  Changes of haemogram and serum biochemistry in neonatal piglet diarrhoea associated with porcine rotavirus type A.

Authors:  G E Chethan; J Garkhal; Shubhankar Sircar; Y P S Malik; R Mukherjee; V K Gupta; N R Sahoo; R K Agarwal; U K De
Journal:  Trop Anim Health Prod       Date:  2017-07-27       Impact factor: 1.559

2.  Performance of concanavalin A-immobilized on polyacrylate beads for the detection of human norovirus and hepatitis A virus in fecal specimens.

Authors:  Songhak Kim; Susanne U Mertens-Talcott; Bipin Vaidya; Vinicius Paula Venancio; Se-Young Cho; Jong-Am Song; Boon P Chew; Joseph Kwon; Duwoon Kim
Journal:  Food Sci Biotechnol       Date:  2020-11-04       Impact factor: 2.391

3.  Performance Evaluation of the Automated Fluorescent Immunoassay System Rotavirus Assay in Clinical Samples.

Authors:  Jae Seok Kim; Su Kyung Lee; Dae Hyun Ko; Jungwon Hyun; Hyun Soo Kim
Journal:  Ann Lab Med       Date:  2019-01       Impact factor: 3.464

4.  Performance evaluation of Automated Fluorescent Immunoassay System ROTA and NORO for detection of rotavirus and norovirus: A comparative study of assay performance with RIDASCREEN® Rotavirus and Norovirus.

Authors:  Changhee Ha; In Young Yoo; Sun Ae Yun; Yoo Na Chung; Hee Jae Huh; Nam Yong Lee
Journal:  J Clin Lab Anal       Date:  2020-09-23       Impact factor: 2.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.