Figure 1Fusion Maximum Intensity Projection (MIP) of 82Rb-PET/CT scan of a Male Sprague-Dawley rat after myocardial infarction LAD ligation, showing excellent cardiac uptake with practically no background uptake apart from clearance through the kidneys. The animal which was anesthetized using 4 % Sevoflurane in 35 % O2, had a catheter placed in the tail vein, and was placed in a Siemens Inveon pre-clinical PET/CT scanner (Siemens, Knoxville, US). PET acquisition was performed for 5 minutes, with infusion of approximately 40 MBq 82Rb in 2 ml saline over 4-5 seconds from a clinically approved 82Rb generator (CardioGen-82, Bracco Diagnostics Inc., US) simultaneous with PET imaging, followed by a CT scan for anatomical co-registration and attenuation correction. PET list-mode data were histogrammed into two timeframes, the first 45 seconds and the remaining 255 seconds (the latter is shown here), and images were reconstructed using scatter and attenuation corrected OP-MAP / 3D-OSEM with 3 mm requested resolution, 18 and 2 subsets, respectively. All experiments were approved by the Danish Animal Experiments Inspectorate (Permit No. 2012-15-2934-00064)
Figure 282Rb-PET short axis images of the heart before (left column) and after (middle column) LAD ligation. The reconstructed scan was imported into pMod software (v 3.3, pMod Technologies Ltd, Zürich, Switzerland) and reoriented to short axis view. After the second PET/CT scan, the animal was injected with 40-50 MBq of 99mTc-Sestamibi and after 10 minutes the animal was euthanized by decapitation. The heart was rapidly excised and snap-frozen in liquid nitrogen. The frozen heart was casted in Tissue-Tek (Sakura, NL) and 20 slides (8 µm thick) were made, 240 µm apart, covering the infarcted area. The slides were exposed to a radiosensitive phosphor film and developed in a phosphor imager (Cyclone Plus, PerkinElmer Inc., US). The right panels show the resulting ex vivo autoradiography images of histological slices corresponding to the PET images. The infarcted area is marked by an arrow on both the 82Rb-PET and the autoradiography. The star (*) denotes a slicing artifact