Literature DB >> 27288764

Relative sensitivities of DCE-MRI pharmacokinetic parameters to arterial input function (AIF) scaling.

Xin Li1, Yu Cai2, Brendan Moloney2, Yiyi Chen3, Wei Huang2, Mark Woods4, Fergus V Coakley5, William D Rooney2, Mark G Garzotto6, Charles S Springer2.   

Abstract

Dynamic-Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) has been used widely for clinical applications. Pharmacokinetic modeling of DCE-MRI data that extracts quantitative contrast reagent/tissue-specific model parameters is the most investigated method. One of the primary challenges in pharmacokinetic analysis of DCE-MRI data is accurate and reliable measurement of the arterial input function (AIF), which is the driving force behind all pharmacokinetics. Because of effects such as inflow and partial volume averaging, AIF measured from individual arteries sometimes require amplitude scaling for better representation of the blood contrast reagent (CR) concentration time-courses. Empirical approaches like blinded AIF estimation or reference tissue AIF derivation can be useful and practical, especially when there is no clearly visible blood vessel within the imaging field-of-view (FOV). Similarly, these approaches generally also require magnitude scaling of the derived AIF time-courses. Since the AIF varies among individuals even with the same CR injection protocol and the perfect scaling factor for reconstructing the ground truth AIF often remains unknown, variations in estimated pharmacokinetic parameters due to varying AIF scaling factors are of special interest. In this work, using simulated and real prostate cancer DCE-MRI data, we examined parameter variations associated with AIF scaling. Our results show that, for both the fast-exchange-limit (FXL) Tofts model and the water exchange sensitized fast-exchange-regime (FXR) model, the commonly fitted CR transfer constant (K(trans)) and the extravascular, extracellular volume fraction (ve) scale nearly proportionally with the AIF, whereas the FXR-specific unidirectional cellular water efflux rate constant, kio, and the CR intravasation rate constant, kep, are both AIF scaling insensitive. This indicates that, for DCE-MRI of prostate cancer and possibly other cancers, kio and kep may be more suitable imaging biomarkers for cross-platform, multicenter applications. Data from our limited study cohort show that kio correlates with Gleason scores, suggesting that it may be a useful biomarker for prostate cancer disease progression monitoring.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  AIF scaling; Arterial input function; Contrast reagent; Dynamic-Contrast-Enhanced; Prostate cancer; Water exchange

Mesh:

Substances:

Year:  2016        PMID: 27288764      PMCID: PMC4958517          DOI: 10.1016/j.jmr.2016.05.018

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  30 in total

1.  Gd-DTPA relaxivity depends on macromolecular content.

Authors:  G J Stanisz; R M Henkelman
Journal:  Magn Reson Med       Date:  2000-11       Impact factor: 4.668

2.  Evidence for weak protein binding of commercial extracellular gadolinium contrast agents.

Authors:  Yan Wang; Marga Spiller; Peter Caravan
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

3.  A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations.

Authors:  Matthias C Schabel; Jacob U Fluckiger; Edward V R DiBella
Journal:  Phys Med Biol       Date:  2010-08-03       Impact factor: 3.609

4.  MRI and quantitative autoradiographic studies following bolus injections of unlabeled and (14)C-labeled gadolinium-diethylenetriaminepentaacetic acid in a rat model of stroke yield similar distribution volumes and blood-to-brain influx rate constants.

Authors:  Tavarekere N Nagaraja; James R Ewing; Kishor Karki; Paul E Jacobs; George W Divine; Joseph D Fenstermacher; Clifford S Patlak; Robert A Knight
Journal:  NMR Biomed       Date:  2010-12-12       Impact factor: 4.044

5.  Frequency and determinants of disagreement and error in gleason scores: a population-based study of prostate cancer.

Authors:  Michael Goodman; Kevin C Ward; Adeboye O Osunkoya; Milton W Datta; Daniel Luthringer; Andrew N Young; Katerina Marks; Vaunita Cohen; Jan C Kennedy; Michael J Haber; Mahul B Amin
Journal:  Prostate       Date:  2012-01-06       Impact factor: 4.104

6.  Diffusion into rat brain of contrast and shift reagents for magnetic resonance imaging and spectroscopy.

Authors:  E Preston; D O Foster
Journal:  NMR Biomed       Date:  1993 Sep-Oct       Impact factor: 4.044

7.  Variation of the relaxographic "shutter-speed" for transcytolemmal water exchange affects the CR bolus-tracking curve shape.

Authors:  Thomas E Yankeelov; William D Rooney; Xin Li; Charles S Springer
Journal:  Magn Reson Med       Date:  2003-12       Impact factor: 4.668

8.  Cell membrane water exchange effects in prostate DCE-MRI.

Authors:  Xin Li; Ryan A Priest; William J Woodward; Faisal Siddiqui; Tomasz M Beer; Mark G Garzotto; William D Rooney; Charles S Springer
Journal:  J Magn Reson       Date:  2012-03-28       Impact factor: 2.229

Review 9.  Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols.

Authors:  P S Tofts; G Brix; D L Buckley; J L Evelhoch; E Henderson; M V Knopp; H B Larsson; T Y Lee; N A Mayr; G J Parker; R E Port; J Taylor; R M Weisskoff
Journal:  J Magn Reson Imaging       Date:  1999-09       Impact factor: 4.813

10.  Mapping human brain capillary water lifetime: high-resolution metabolic neuroimaging.

Authors:  William D Rooney; Xin Li; Manoj K Sammi; Dennis N Bourdette; Edward A Neuwelt; Charles S Springer
Journal:  NMR Biomed       Date:  2015-04-27       Impact factor: 4.044

View more
  15 in total

1.  Dynamic Contrast-Enhanced MRI-Derived Intracellular Water Lifetime (τ i ): A Prognostic Marker for Patients with Head and Neck Squamous Cell Carcinomas.

Authors:  S Chawla; L A Loevner; S G Kim; W-T Hwang; S Wang; G Verma; S Mohan; V LiVolsi; H Quon; H Poptani
Journal:  AJNR Am J Neuroradiol       Date:  2017-11-16       Impact factor: 3.825

2.  Comparison of region-of-interest-averaged and pixel-averaged analysis of DCE-MRI data based on simulations and pre-clinical experiments.

Authors:  Dianning He; Marta Zamora; Aytekin Oto; Gregory S Karczmar; Xiaobing Fan
Journal:  Phys Med Biol       Date:  2017-09-05       Impact factor: 3.609

3.  Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI.

Authors:  Sharon Peled; Mark Vangel; Ron Kikinis; Clare M Tempany; Fiona M Fennessy; Andrey Fedorov
Journal:  Acad Radiol       Date:  2018-11-20       Impact factor: 3.173

4.  Estimation of cellular-interstitial water exchange in dynamic contrast enhanced MRI using two flip angles.

Authors:  Jin Zhang; Sungheon Gene Kim
Journal:  NMR Biomed       Date:  2019-07-26       Impact factor: 4.044

5.  Differentiation between glioblastoma and primary CNS lymphoma: application of DCE-MRI parameters based on arterial input function obtained from DSC-MRI.

Authors:  Koung Mi Kang; Seung Hong Choi; Park Chul-Kee; Tae Min Kim; Sung-Hye Park; Joo Ho Lee; Soon-Tae Lee; Inpyeong Hwang; Roh-Eul Yoo; Tae Jin Yun; Ji-Hoon Kim; Chul-Ho Sohn
Journal:  Eur Radiol       Date:  2021-05-18       Impact factor: 5.315

6.  Linearization improves the repeatability of quantitative dynamic contrast-enhanced MRI.

Authors:  Kyle M Jones; Mark D Pagel; Julio Cárdenas-Rodríguez
Journal:  Magn Reson Imaging       Date:  2017-11-15       Impact factor: 2.546

7.  Predicting clinically significant prostate cancer from quantitative image features including compressed sensing radial MRI of prostate perfusion using machine learning: comparison with PI-RADS v2 assessment scores.

Authors:  David Jean Winkel; Hanns-Christian Breit; Bibo Shi; Daniel T Boll; Hans-Helge Seifert; Christian Wetterauer
Journal:  Quant Imaging Med Surg       Date:  2020-04

8.  Pseudo Test-Retest Evaluation of Millimeter-Resolution Whole-Brain Dynamic Contrast-enhanced MRI in Patients with High-Grade Glioma.

Authors:  Yannick Bliesener; R Marc Lebel; Jay Acharya; Richard Frayne; Krishna S Nayak
Journal:  Radiology       Date:  2021-06-08       Impact factor: 29.146

9.  The Impact of Arterial Input Function Determination Variations on Prostate Dynamic Contrast-Enhanced Magnetic Resonance Imaging Pharmacokinetic Modeling: A Multicenter Data Analysis Challenge, Part II.

Authors:  Wei Huang; Yiyi Chen; Andriy Fedorov; Xia Li; Guido H Jajamovich; Dariya I Malyarenko; Madhava P Aryal; Peter S LaViolette; Matthew J Oborski; Finbarr O'Sullivan; Richard G Abramson; Kourosh Jafari-Khouzani; Aneela Afzal; Alina Tudorica; Brendan Moloney; Sandeep N Gupta; Cecilia Besa; Jayashree Kalpathy-Cramer; James M Mountz; Charles M Laymon; Mark Muzi; Paul E Kinahan; Kathleen Schmainda; Yue Cao; Thomas L Chenevert; Bachir Taouli; Thomas E Yankeelov; Fiona Fennessy; Xin Li
Journal:  Tomography       Date:  2019-03

10.  NMR shutter-speed elucidates apparent population inversion of 1 H2 O signals due to active transmembrane water cycling.

Authors:  Xin Li; Silvia Mangia; Jing-Huei Lee; Ruiliang Bai; Charles S Springer
Journal:  Magn Reson Med       Date:  2019-03-22       Impact factor: 4.668

View more