Literature DB >> 27278958

The phenomenon of drop in output at larger field sizes for telecobalt units.

Sukhvir Singh1, Ajay K Singh1, Manoj K Semwal2, Virender Suhag1, Arti Sarin1, Aruna Kaushik3.   

Abstract

It is known that the output factors (OPFs) for external-beam radiotherapy units increase with field size due to increased scattered radiation from the collimator system. Saturation in the OPF value is generally reported beyond approximately 30 × 30 cm(2). For the first time, to the best of our knowledge, we report on a drop in OPF values, although marginal, measured for a telecobalt machine beyond the 38 × 38 cm(2) field size. We believe that reporting and explaining the results will lead to a better understanding of the scatter composition of the radiation from telecobalt machines. This also has the potential to impact the estimation of low dose regions in patients, in addition to being a purely scientific inquiry. We used Monte Carlo (MC) simulations to validate the measured values. The MC data showed that the decrease in OPF was due to decreased scatter from the machine head.

Entities:  

Keywords:  Larger fields; Output factors; Telecobalt units

Mesh:

Year:  2016        PMID: 27278958     DOI: 10.1007/s12194-016-0363-4

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  8 in total

1.  Monte Carlo simulation of a typical 60Co therapy source.

Authors:  G M Mora; A Maio; D W Rogers
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM.

Authors:  P Francescon; C Cavedon; S Reccanello; S Cora
Journal:  Med Phys       Date:  2000-07       Impact factor: 4.071

3.  Monte Carlo dose calculations for radiotherapy machines: Theratron 780-C teletherapy case study.

Authors:  B Teimouri Sichani; M Sohrabpour
Journal:  Phys Med Biol       Date:  2004-03-07       Impact factor: 3.609

4.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units.

Authors:  D W Rogers; B A Faddegon; G X Ding; C M Ma; J We; T R Mackie
Journal:  Med Phys       Date:  1995-05       Impact factor: 4.071

5.  Monte Carlo simulation based study of a proposed multileaf collimator for a telecobalt machine.

Authors:  G Sahani; Sunil Dutt Sharma; P K Dash Sharma; D N Sharma; S A Hussain
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

6.  Monte Carlo simulation of a cobalt-60 beam.

Authors:  K Han; D Ballon; C Chui; R Mohan
Journal:  Med Phys       Date:  1987 May-Jun       Impact factor: 4.071

7.  Gamma radiation from cobalt 60 teletherapy units.

Authors:  T J Godden
Journal:  Br J Radiol Suppl       Date:  1983

8.  Monte Carlo simulation of a multi-leaf collimator design for telecobalt machine using BEAMnrc code.

Authors:  Komanduri M Ayyangar; M Dinesh Kumar; Pradush Narayan; Fenedit Jesuraj; M R Raju
Journal:  J Med Phys       Date:  2010-01
  8 in total