Literature DB >> 10947261

Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM.

P Francescon1, C Cavedon, S Reccanello, S Cora.   

Abstract

The purpose of this work is to compare the photon dose calculation of a commercially available three-dimensional (3D) treatment planning system based on the collapsed cone convolution technique against BEAM, a Monte Carlo code that allows detailed simulation of a radiotherapy accelerator. The first part of the work is devoted to the commissioning of BEAM for a 6 MV photon beam and to the optimization of the linac description to fit the experimental data. This step also involves a comparison with radiochromic film data on an inhomogeneous phantom built to simulate electronic nonequilibrium conditions. Commissioning the selected photon beams required a careful description of the treatment head and the fine tuning of physical parameters such as electron beam energy and radius. The second part shows the dose comparison for real patient's CT data sets: A mediastinal treatment and a breast treatment were simulated. Doses in terms of absolute values per monitor unit were calculated based on the BEAM simulation of the CT data sets. For comparisons of real-patient cases, differences between the treatment planning system and BEAM ranged from 0 to 2.6% and were within +/-2 standard deviations for the dose calculated at the prescription point. Dose-volume histogram analysis indicated that there is no consistent difference between the Monte Carlo and the convolution calculations. On the basis of the results presented in this study, we can conclude that the CCC algorithm is capable of giving results absolutely comparable to those of a Monte Carlo calculation, as far as common 3D radiotherapy planning is concerned.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10947261     DOI: 10.1118/1.599024

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  The phenomenon of drop in output at larger field sizes for telecobalt units.

Authors:  Sukhvir Singh; Ajay K Singh; Manoj K Semwal; Virender Suhag; Arti Sarin; Aruna Kaushik
Journal:  Radiol Phys Technol       Date:  2016-06-08

2.  Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center's anthropomorphic thorax phantom used for RTOG credentialing.

Authors:  Stephen F Kry; Paola Alvarez; Andrea Molineu; Carrie Amador; James Galvin; David S Followill
Journal:  Int J Radiat Oncol Biol Phys       Date:  2013-01-01       Impact factor: 7.038

3.  Assessment of skin dose in breast cancer radiotherapy: on-phantom measurement and Monte Carlo simulation.

Authors:  Mohammad Taghi Bahreyni Toossi; Nastaran Mohamadian; Mohammad Mohammadi; Mahdi Ghorbani; Mohsen Hassani; Benyamin Khajetash; Farideh Khorshidi; Courtney Knaup
Journal:  Rep Pract Oncol Radiother       Date:  2020-03-18

4.  Verification of the accuracy of a photon dose-calculation algorithm.

Authors:  Kent A Gifford; David S Followill; H Helen Liu; George Starkschall
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.