Literature DB >> 14666265

Initial experience in Brazil with the Helex septal occluder for percutaneous occlusion of atrial septal defects.

Carlos A C Pedra1, Simone F Pedra, César A Esteves, Francisco Chamiê, Sérgio Ramos, Sérgio C Pontes, João Carlos Tress, Sérgio L N Braga, Larry A Latson, Valmir F Fontes.   

Abstract

OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects.
METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 3.3mm, and 15.2 3.8mm, respectively. The Qp/Qs ratio was 1.9 0.3 in patients with ASD.
RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences.
CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.

Entities:  

Mesh:

Year:  2003        PMID: 14666265     DOI: 10.1590/s0066-782x2003001300001

Source DB:  PubMed          Journal:  Arq Bras Cardiol        ISSN: 0066-782X            Impact factor:   2.000


  3 in total

1.  Initial Experience with the Nit-Occlud ASD-R: Short-Term Results.

Authors:  Mustafa Orhan Bulut; Ilker Kemal Yucel; Mehmet Kucuk; Sevket Balli; Evic Zeynep Basar; Ahmet Celebi
Journal:  Pediatr Cardiol       Date:  2016-06-09       Impact factor: 1.655

2.  First experience with the 2005 modified Gore Helex ASD occluder system.

Authors:  R Kozlik-Feldmann; R Dalla Pozza; U Römer; T Rampp; P Bernasconi; S Däbritz; H Netz
Journal:  Clin Res Cardiol       Date:  2006-07-20       Impact factor: 5.460

3.  Transesophageal echocardiography and fluoroscopy for percutaneous closure of atrial septal defects: A comparative study.

Authors:  Weize Xu; Jianhua Li; Jingjing Ye; Jin Yu; Jiangen Yu; Zewei Zhang
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  3 in total