Literature DB >> 27274470

Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition.

Won Seok Oh1, Yong Seuk Lee2, Byung Kak Kim3, Jae Ang Sim3, Beom Koo Lee3.   

Abstract

PURPOSE: To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs.
MATERIALS AND METHODS: From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia.
RESULTS: Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition.
CONCLUSIONS: In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.

Entities:  

Keywords:  Arthroplasty; Contact point; Knee; Osteoarthritis; Rotating platform

Year:  2016        PMID: 27274470      PMCID: PMC4895085          DOI: 10.5792/ksrr.2016.28.2.137

Source DB:  PubMed          Journal:  Knee Surg Relat Res        ISSN: 2234-0726


  20 in total

1.  Multicenter determination of in vivo kinematics after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Brian D Haas; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

2.  Cemented rotating-platform total knee replacement: a concise follow-up, at a minimum of twenty years, of a previous report.

Authors:  John J Callaghan; Christopher W Wells; Steve S Liu; Devon D Goetz; Richard C Johnston
Journal:  J Bone Joint Surg Am       Date:  2010-07-07       Impact factor: 5.284

3.  The effect of sagittal laxity on function after posterior cruciate-retaining total knee replacement.

Authors:  David P Gwynne Jones; Conlin Locke; Jonathon Pennington; Jean-Claude Theis
Journal:  J Arthroplasty       Date:  2006-08       Impact factor: 4.757

4.  Safety and efficacy of a rotating-platform, high-flexion knee design three- to five-year follow-up.

Authors:  Morteza Meftah; Amar S Ranawat; Chitranjan S Ranawat
Journal:  J Arthroplasty       Date:  2011-05-31       Impact factor: 4.757

5.  Postoperative flexion analysis of 3 rotating-platform knee designs.

Authors:  Rajesh N Maniar; Singhi Tushar; Ashish Singh; Himanshu Gupta; Arun Nanivadekar; Parul Rajesh Maniar
Journal:  Orthopedics       Date:  2012-08-01       Impact factor: 1.390

6.  High-flex rotating platform knee implants: two- to 6-year results of a prospective study.

Authors:  Rajesh N Maniar; Tushar Singhi
Journal:  J Arthroplasty       Date:  2011-09-23       Impact factor: 4.757

7.  The long-term results of simultaneous fixed-bearing and mobile-bearing total knee replacements performed in the same patient.

Authors:  Y-H Kim; S-H Yoon; J-S Kim
Journal:  J Bone Joint Surg Br       Date:  2007-10

8.  A new measurement technique for the tibiofemoral contact point in normal knees and knees with TKR.

Authors:  R J de Jong; P J C Heesterbeek; A B Wymenga
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-11-28       Impact factor: 4.342

9.  Sagittal laxity after posterior cruciate ligament-retaining mobile-bearing total knee arthroplasty.

Authors:  Julien Chouteau; Jean Luc Lerat; Rodolph Testa; Bernard Moyen; Scott A Banks; Banks A Scott
Journal:  J Arthroplasty       Date:  2008-08-12       Impact factor: 4.757

10.  Uncemented rotating-platform total knee replacement: a five to twelve-year follow-up study.

Authors:  R Barry Sorrells; Paul E Voorhorst; Jeffrey A Murphy; Maryrose P Bauschka; A Seth Greenwald
Journal:  J Bone Joint Surg Am       Date:  2004-10       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.