Literature DB >> 22868599

Postoperative flexion analysis of 3 rotating-platform knee designs.

Rajesh N Maniar1, Singhi Tushar, Ashish Singh, Himanshu Gupta, Arun Nanivadekar, Parul Rajesh Maniar.   

Abstract

Rotating-platform knee implants have successively undergone modifications to improve postoperative flexion. The cruciate-sacrificing Low Contact Stress (LCS) implant (DePuy Orthopaedics, Inc, Warsaw, Indiana) was modified into the cruciate-substituting PFC Sigma RP (ΣRP) implant and further into the PFC Sigma RPF (ΣRPF) implant (DePuy Orthopaedics, Inc). The goal of this study was to determine whether these modifications improved postoperative flexion. Postoperative flexion at 2 years was compared against preoperative flexion with regard to the general demographics of each group.Statistical analysis showed that the pre- to postoperative flexion changes achieved by the ΣRP (14.6°) and the ΣRPF (2.9°) were better (P<.001) than that achieved by the LCS (-10.3°); however, between the ΣRP (14.6°) and the ΣRPF (2.9°), the change was statistically insignificant (P=.045). In subgroups with preoperative flexion less than 125°, postoperative flexion achieved was 100.1° with the LCS, 119.8° with the ΣRP, and 121.3° with the ΣRPF. The difference between the ΣRP and ΣRPF and the LCS was statistically significant (P<.001), but between the ΣRP and the ΣRPF was statistically insignificant (P=.621). In subgroups with preoperative flexion 125° or more, postoperative flexion was 125° with the LCS, 132° with the ΣRP, and 130° with the ΣRPF, with no significant difference between groups (P=.416). Both cruciate-substituting designs produced better postoperative flexion than the cruciate-sacrificing design. The ΣRP, despite less preoperative flexion (P=.004), achieved statistically better postoperative flexion than the LCS (P<.001). In subgroups with comparable preoperative flexion, no statistical difference in postoperative flexion was achieved by the ΣRP and the ΣRPF. Copyright 2012, SLACK Incorporated.

Entities:  

Mesh:

Year:  2012        PMID: 22868599     DOI: 10.3928/01477447-20120725-13

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  2 in total

1.  Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition.

Authors:  Won Seok Oh; Yong Seuk Lee; Byung Kak Kim; Jae Ang Sim; Beom Koo Lee
Journal:  Knee Surg Relat Res       Date:  2016-06-01

2.  Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F.

Authors:  Jun-Young Kim; Sang-Ho Cheon; Hee-Soo Kyung
Journal:  Knee Surg Relat Res       Date:  2012-11-29