Literature DB >> 27253137

Sensitive and Quantitative Detection of C-Reaction Protein Based on Immunofluorescent Nanospheres Coupled with Lateral Flow Test Strip.

Jiao Hu1, Zhi-Ling Zhang1, Cong-Ying Wen1, Man Tang1, Ling-Ling Wu1, Cui Liu1, Lian Zhu1, Dai-Wen Pang1.   

Abstract

Sensitive and quantitative detection of protein biomarkers with a point-of-care (POC) assay is significant for early diagnosis, treatment, and prognosis of diseases. In this paper, a quantitative lateral flow assay with high sensitivity for protein biomarkers was established by utilizing fluorescent nanospheres (FNs) as reporters. Each fluorescent nanosphere (FN) contains 332 ± 8 CdSe/ZnS quantum dots (QDs), leading to its superstrong luminescence, 380-fold higher than that of one QD. Then a detection limit of 27.8 pM C-reaction protein (CRP) could be achieved with an immunofluorescent nanosphere (IFN)-based lateral flow test strip. The assay was 257-fold more sensitive than that with a conventional Au-based lateral flow test strip for CRP detection. Besides, the fluorescence intensity of FNs and bioactivity of IFNs were stable during 6 months of storage. Hence, the assay owns good reproducibility (intra-assay variability of 5.3% and interassay variability of 6.6%). Furthermore, other cancer biomarkers (PSA, CEA, AFP) showed negative results by this method, validating the excellent specificity of the method. Then the assay was successfully applied to quantitatively detect CRP in peripheral blood plasma samples from lung cancer and breast cancer patients, and healthy people, facilitating the diagnosis of lung cancer. It holds a good prospect of POC protein biomarker detection.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27253137     DOI: 10.1021/acs.analchem.6b01427

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  20 in total

1.  Highly sensitive protein detection using recombinant spores and lateral flow immunoassay.

Authors:  Wen-Zhi Lin; I-Cheng Ma; Jun-Pei Wang; Ping-Chun Hsieh; Cheng-Che Liu; Shao-Yi Hou
Journal:  Anal Bioanal Chem       Date:  2021-02-19       Impact factor: 4.142

2.  Aptamer-functionalized magnetic and fluorescent nanospheres for one-step sensitive detection of thrombin.

Authors:  Cong-Ying Wen; Jia-Hui Bi; Ling-Ling Wu; Jing-Bin Zeng
Journal:  Mikrochim Acta       Date:  2017-12-22       Impact factor: 5.833

3.  Fluorometric immunoassay for the simultaneous determination of the tumor markers carcinoembryonic antigen and cytokeratin 19 fragment using two kinds of CdSe/ZnS quantum dot nanobeads and magnetic beads.

Authors:  Lihua Ding; Xiao Chen; Leiliang He; Fei Yu; Songcheng Yu; Jia Wang; Yongmei Tian; Yilin Wang; Yongjun Wu; Li-E Liu; Lingbo Qu
Journal:  Mikrochim Acta       Date:  2020-02-15       Impact factor: 5.833

4.  An anti-BSA antibody-based immunochromatographic assay for chloramphenicol and aflatoxin M1 by using carboxy-modified CdSe/ZnS core-shell nanoparticles as label.

Authors:  Zhiwei Qie; Wenliang Yan; Zichen Gao; Wu Meng; Rui Xiao; Shengqi Wang
Journal:  Mikrochim Acta       Date:  2019-12-03       Impact factor: 5.833

5.  Functionalized ultra-fine bimetallic PtRu alloy nanoparticle with high peroxidase-mimicking activity for rapid and sensitive colorimetric quantification of C-reactive protein.

Authors:  Pramod K Gupta; Seong Eun Son; Gi Hun Seong
Journal:  Mikrochim Acta       Date:  2021-03-09       Impact factor: 5.833

6.  Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip).

Authors:  Meili Dong; Jiandong Wu; Zimin Ma; Hagit Peretz-Soroka; Michael Zhang; Paul Komenda; Navdeep Tangri; Yong Liu; Claudio Rigatto; Francis Lin
Journal:  Sensors (Basel)       Date:  2017-03-26       Impact factor: 3.576

7.  Ultrabright fluorescent nanoscale labels for the femtomolar detection of analytes with standard bioassays.

Authors:  Jingyi Luan; Anushree Seth; Rohit Gupta; Zheyu Wang; Priya Rathi; Sisi Cao; Hamed Gholami Derami; Rui Tang; Baogang Xu; Samuel Achilefu; Jeremiah J Morrissey; Srikanth Singamaneni
Journal:  Nat Biomed Eng       Date:  2020-04-20       Impact factor: 25.671

8.  Fluorescent hollow ZrO2@CdTe nanoparticles-based lateral flow assay for simultaneous detection of C-reactive protein and troponin T.

Authors:  Xin Liu; Xiangling Ren; Lufeng Chen; Jian Zou; Ting Li; Longfei Tan; Changhui Fu; Qiong Wu; Chaohui Li; Jiayi Wang; Zhongbing Huang; Xianwei Meng
Journal:  Mikrochim Acta       Date:  2021-05-28       Impact factor: 5.833

9.  A sensitive and innovative detection method for rapid C-reactive proteins analysis based on a micro-fluxgate sensor system.

Authors:  Lei Guo; Zhen Yang; Shaotao Zhi; Zhu Feng; Chong Lei; Yong Zhou
Journal:  PLoS One       Date:  2018-03-30       Impact factor: 3.240

10.  Rapid Detection of Rongalite via a Sandwich Lateral Flow Strip Assay Using a Pair of Aptamers.

Authors:  Jie Li; Le Jing; Yuzhu Song; Jinyang Zhang; Qiang Chen; Binghui Wang; Xueshan Xia; Qinqin Han
Journal:  Nanoscale Res Lett       Date:  2018-09-24       Impact factor: 4.703

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.