Literature DB >> 34047819

Fluorescent hollow ZrO2@CdTe nanoparticles-based lateral flow assay for simultaneous detection of C-reactive protein and troponin T.

Xin Liu1,2,3, Xiangling Ren1,3,4, Lufeng Chen5, Jian Zou1,2,3, Ting Li1,3,4, Longfei Tan1,3, Changhui Fu1,3, Qiong Wu1,3, Chaohui Li6, Jiayi Wang6, Zhongbing Huang2, Xianwei Meng7,8.   

Abstract

Highly fluorescent hollow ZrO2@CdTe nanoparticles (NPs) were synthesized efficiently via the hydrothermal method. By changing the hydrothermal time of ZrO2@CdTe NP, the peaks of fluorescence spectra measured at fluorescent excitation of 330 nm were at 540 nm, 590 nm, and 640 nm, respectively. Hollow ZrO2 NPs have a uniform core-shell structure with the size of 178 ± 10 nm and shell of 19 ± 4 nm. The as-prepared yellow-ZrO2@CdTe NPs were used to develop lateral flow assay (LFA) for the sensitive and qualitative detection of C-reactive protein (CRP). The visual limit of detection of the LFA for the CRP antigen was 1 μg/L within 20 min, which is 1000-fold lower than that of colloidal gold-based LFA. In addition, a multiplex lateral flow assay (mLFA) was developed using the as-prepared green and red-ZrO2@CdTe NPs for the simultaneous, specific, sensitive, and qualitative detection of CRP and troponin T (cTnT). The visual limits of detection of CRP and cTnT in mLFA were 10 μg/L and 0.1 mg/L, respectively. The excellent performance of ZrO2@CdTe NPs should facilitate their application in point-of-care technology for the detection of other biomarkers.

Entities:  

Keywords:  Cardiac biomarkers; Fluorescence detection; Lateral flow assay; Multiple detection; ZrO2@CdTe nanoparticles

Mesh:

Substances:

Year:  2021        PMID: 34047819     DOI: 10.1007/s00604-021-04865-3

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  18 in total

1.  Rapid and sensitive detection of protein biomarker using a portable fluorescence biosensor based on quantum dots and a lateral flow test strip.

Authors:  Zhaohui Li; Ying Wang; Jun Wang; Zhiwen Tang; Joel G Pounds; Yuehe Lin
Journal:  Anal Chem       Date:  2010-08-15       Impact factor: 6.986

Review 2.  Synthesis and Biomedical Applications of Poly((meth)acrylic acid) Brushes.

Authors:  Zhenyuan Qu; Hong Xu; Hongchen Gu
Journal:  ACS Appl Mater Interfaces       Date:  2015-07-01       Impact factor: 9.229

3.  CdTe@SiO2 signal reporters-based fluorescent immunosensor for quantitative detection of prostate specific antigen.

Authors:  Yuting Zhao; Wen Gao; Xiaoxiao Ge; Suiqiong Li; Dan Du; Haipeng Yang
Journal:  Anal Chim Acta       Date:  2019-01-18       Impact factor: 6.558

4.  Fast synthesis of fluorescent SiO2@CdTe nanoparticles with reusability in detection of H2O2.

Authors:  Jiejie Ge; Xiangling Ren; Xiaozhong Qiu; Haitang Shi; Xianwei Meng; Fangqiong Tang
Journal:  J Mater Chem B       Date:  2015-07-13       Impact factor: 6.331

5.  A silica nanoparticle based 2-color immunochromatographic assay for simultaneous determination of clenbuterol and ractopamine.

Authors:  Qiongqiong Yu; Jing Liu; Guangying Zhao; Wenchao Dou
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

6.  Portable Multiplex Immunochromatographic Assay for Quantitation of Two Typical Algae Toxins Based on Dual-Color Fluorescence Microspheres.

Authors:  Huiyan Zhang; Jiaxun Luo; Natalia Beloglazova; Shupeng Yang; Sarah De Saeger; Ghulam Mujtaba Mari; Suxia Zhang; Jianzhong Shen; Zhanhui Wang; Xuezhi Yu
Journal:  J Agric Food Chem       Date:  2019-05-16       Impact factor: 5.279

7.  Sensitive and Quantitative Detection of C-Reaction Protein Based on Immunofluorescent Nanospheres Coupled with Lateral Flow Test Strip.

Authors:  Jiao Hu; Zhi-Ling Zhang; Cong-Ying Wen; Man Tang; Ling-Ling Wu; Cui Liu; Lian Zhu; Dai-Wen Pang
Journal:  Anal Chem       Date:  2016-06-13       Impact factor: 6.986

8.  Direct vs Mediated Coupling of Antibodies to Gold Nanoparticles: The Case of Salivary Cortisol Detection by Lateral Flow Immunoassay.

Authors:  Fabio Di Nardo; Simone Cavalera; Claudio Baggiani; Cristina Giovannoli; Laura Anfossi
Journal:  ACS Appl Mater Interfaces       Date:  2019-09-03       Impact factor: 9.229

9.  A fluorescent nanosphere-based immunochromatography test strip for ultrasensitive and point-of-care detection of tetanus antibody in human serum.

Authors:  Juan Chen; Hong-Min Meng; Ying An; Juanzu Liu; Ran Yang; Lingbo Qu; Zhaohui Li
Journal:  Anal Bioanal Chem       Date:  2019-12-23       Impact factor: 4.142

10.  Development of a lateral flow immunoassay of C-reactive protein detection based on red fluorescent nanoparticles.

Authors:  Yanxue Cai; Keren Kang; Yujia Liu; Yu Wang; Xiaowei He
Journal:  Anal Biochem       Date:  2018-06-30       Impact factor: 3.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.