Literature DB >> 31797114

An anti-BSA antibody-based immunochromatographic assay for chloramphenicol and aflatoxin M1 by using carboxy-modified CdSe/ZnS core-shell nanoparticles as label.

Zhiwei Qie1, Wenliang Yan1, Zichen Gao2, Wu Meng2, Rui Xiao3, Shengqi Wang4.   

Abstract

A lateral-flow immunochromatographic assay with excellent sensitivity and wide application potential is described. The bovine serum albumin (BSA) antibody was immobilized in the test line for universality, and preincubation was introduced for high method sensitivity. Carboxy-modified CdSe/ZnS core-shell nanoparticles were used as label, and the fluorescence peaking at 605 nm was detected. The fluorescence in the test line was negative against the relevant analyte content. The chloramphenicol (CAP) and the aflatoxin M1 (AFM1) in milk were detected using the same strip to validate the universality. After optimization, the detection limit for CAP is 10 pg·mL-1, which is three times less that of a conventional assay (30 pg·mL-1). The detection limit for AFM1 was 6 pg·mL-1, which was 13 times less than that of a conventional assay (8 pg·mL-1). The method was applied in the analysis of spiked milk samples. The performance was compared with that of the commercial ELISA kit, and good agreement was observed. Graphical abstractSchematic representation of the universal and sensitive combined immunochromatographic assay (USICA) and conventional immunochromatographic assay (TICA) of chloramphenicol (CAP) and aflatoxin M1.

Entities:  

Keywords:  Competitive recognition; Immunoassay; Milk; Mycotoxin; Pre-incubation; Sensitivity; Universality

Mesh:

Substances:

Year:  2019        PMID: 31797114     DOI: 10.1007/s00604-019-4009-1

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  29 in total

1.  Immunochromatographic assay for quantitative and sensitive detection of hepatitis B virus surface antigen using highly luminescent quantum dot-beads.

Authors:  Jun Shen; Yaofeng Zhou; Fen Fu; Hengyi Xu; Jiaofeng Lv; Yonghua Xiong; Andrew Wang
Journal:  Talanta       Date:  2015-04-27       Impact factor: 6.057

2.  Universal and Ultrasensitive Immunochromatographic Assay by Using an Antigen as a Bifunctional Element and Antialbumin Antibody on a Test Line.

Authors:  Zhiwei Qie; Qiqi Liu; Wenliang Yan; Zichen Gao; Wu Meng; Rui Xiao; Shengqi Wang
Journal:  Anal Chem       Date:  2019-07-08       Impact factor: 6.986

3.  'Traffic light' immunochromatographic test based on multicolor quantum dots for the simultaneous detection of several antibiotics in milk.

Authors:  N A Taranova; A N Berlina; A V Zherdev; B B Dzantiev
Journal:  Biosens Bioelectron       Date:  2014-07-25       Impact factor: 10.618

4.  Lateral flow assay for simultaneous detection of cellular- and humoral immune responses.

Authors:  Paul L A M Corstjens; Claudia J de Dood; Jolien J van der Ploeg-van Schip; Karien C Wiesmeijer; Terhi Riuttamäki; Krista E van Meijgaarden; John S Spencer; Hans J Tanke; Tom H M Ottenhoff; Annemieke Geluk
Journal:  Clin Biochem       Date:  2011-07-06       Impact factor: 3.281

5.  Quantum dot-based immunochromatography test strip for rapid, quantitative and sensitive detection of alpha fetoprotein.

Authors:  Qiuhua Yang; Xiaoqun Gong; Tao Song; Jiumin Yang; Shengjiang Zhu; Yunhong Li; Ye Cui; Yingxin Li; Bingbo Zhang; Jin Chang
Journal:  Biosens Bioelectron       Date:  2011-09-16       Impact factor: 10.618

6.  Validation and long term performance characteristics of a quantitative enzyme linked immunosorbent assay (ELISA) for human anti-PA IgG.

Authors:  V A Semenova; J Schiffer; E Steward-Clark; S Soroka; D S Schmidt; M M Brawner; F Lyde; R Thompson; N Brown; L Foster; S Fox; N Patel; A E Freeman; C P Quinn
Journal:  J Immunol Methods       Date:  2011-12-17       Impact factor: 2.303

7.  Quantum-dot submicrobead-based immunochromatographic assay for quantitative and sensitive detection of zearalenone.

Authors:  Hong Duan; Xuelan Chen; Wei Xu; Jinhua Fu; Yonghua Xiong; Andrew Wang
Journal:  Talanta       Date:  2014-09-06       Impact factor: 6.057

8.  Development of an ultrasensitive aptasensor for the detection of aflatoxin B1.

Authors:  Xiaodong Guo; Fang Wen; Nan Zheng; Qiujiang Luo; Haiwei Wang; Hui Wang; Songli Li; Jiaqi Wang
Journal:  Biosens Bioelectron       Date:  2014-02-02       Impact factor: 10.618

9.  A novel immunochromatographic assay based on a time-resolved chemiluminescence strategy for the multiplexed detection of ractopamine and clenbuterol.

Authors:  Wenwen Wang; Xiaoxiao Su; Hui Ouyang; Lin Wang; Zhifeng Fu
Journal:  Anal Chim Acta       Date:  2016-03-05       Impact factor: 6.558

10.  Lateral flow immunoassay integrated with competitive and sandwich models for the detection of aflatoxin M1 and Escherichia coli O157:H7 in milk.

Authors:  Chun Wang; Juan Peng; Dao-Feng Liu; Ke-Yu Xing; Gang-Gang Zhang; Zhen Huang; Song Cheng; Fang-Fei Zhu; Miao-Lin Duan; Kai-Yi Zhang; Mei-Fang Yuan; Wei-Hua Lai
Journal:  J Dairy Sci       Date:  2018-08-09       Impact factor: 4.034

View more
  2 in total

1.  On-Site Detection of Carcinoembryonic Antigen in Human Serum.

Authors:  Tohid Mahmoudi; Mohammad Pourhassan-Moghaddam; Behnaz Shirdel; Behzad Baradaran; Eden Morales-Narváez; Hamed Golmohammadi
Journal:  Biosensors (Basel)       Date:  2021-10-14

2.  A Sensitive Two-Analyte Immunochromatographic Strip for Simultaneously Detecting Aflatoxin M1 and Chloramphenicol in Milk.

Authors:  Shih-Wei Wu; Jiunn-Liang Ko; Biing-Hui Liu; Feng-Yih Yu
Journal:  Toxins (Basel)       Date:  2020-10-02       Impact factor: 4.546

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.