Literature DB >> 27241335

Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age.

Jan Schmolders1, Grigoris Amvrazis2, Peter H Pennekamp2, Andreas Christian Strauss2, Max Julian Friedrich2, Matthias D Wimmer2, Yorck Rommelspacher2, Dieter Christian Wirtz2, Thomas Wallny2.   

Abstract

PURPOSE: Compared to older patients undergoing total hip arthroplasty (THA) younger patients are considered to be more active, thereby exposing the implant to significantly higher loads over a much longer period of time. Additionally, cases of secondary osteoarthritis caused by hip dysplasia, femoral head necrosis or rheumatic diseases are much more frequent than among the average patient population. Therefore, durable implant fixation and low wear rates are extremely important to achieve good long-term implant survival in this group of patients.
OBJECTIVE: The aim of this retrospective study was to evaluate the mid- to long-term survival of a cementless femoral stem (Zweymüller® SL stem) and a threaded cup (Bicon SL®) in patients younger than 50 years of age.
METHODS: Therefore, a consecutive series of 100 patients (111 hips) aged 50 years or younger (range: 30 to 50 years) was analysed at a mean follow up of 13.5 years. Follow-up assessment included physical examination and radiographic workup. Hip disability osteoarthritis and outcome score (HOOS) and Harris hip score (HHS) were used to evaluate the pre- and post-operative functional outcome, respectively. Patient satisfaction with the surgical result was assessed by standardized questionnaires.
RESULTS: The overall survival rate with any revision as endpoint was 96.8 % (95 % CI: 90.5 % to 98.9 %) at ten years. Gender, operation time and the occurence of osteolyses had no influence on joint function or patient satisfaction. We recorded an overall failure rate of 7.4 % (six cases). In four cases (5 %) the prosthesis had to be revised due to aseptic loosening of the cup after 12 years, eight years, 12 years and 11 years, in one case (1.2 %) recurrent luxation led to a revision operation (acetabular cup and head) after three years of primary implantation. In one case an implant failure was recorded (acetabular cup breakage after eight years of implantation). We recorded the occurence of asymptomatic radiolucent lines of the cup in 21 % and of the stem in 35 % in our series. The HOOS was influenced by the presence or abscence of radiolucent lines of the stem. Patients with radiolucent lines of the stem had a median HOOS score of (74 points) compared to those without radiolucent lines (89 points). Other factors, such as "diagnosis led to operation" and "previous operations" had no influence on the HHS and HOOS.
CONCLUSION: Our study demonstrates excellent long-term survival of cementless femoral stem in combination with a threaded cup in young patients undergoing total hip arthroplasty.

Entities:  

Keywords:  Cementless; Hip replacement; Hip surgery; Long term; Outcome; Total hip arthroplasty

Mesh:

Substances:

Year:  2016        PMID: 27241335     DOI: 10.1007/s00264-016-3226-z

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  34 in total

1.  Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

Authors:  Paul Yuh Feng Lee; Madhu Rachala; Kar Ho Teoh; David John Woodnutt
Journal:  Int Orthop       Date:  2016-01-12       Impact factor: 3.075

2.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

3.  Survivorship of the cementless Spotorno femoral component in patients under 50 years of age at a mean follow-up of 18.4 years.

Authors:  J E Biemond; S Venkatesan; G G van Hellemondt
Journal:  Bone Joint J       Date:  2015-02       Impact factor: 5.082

4.  A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results.

Authors:  K Zweymüller
Journal:  Instr Course Lect       Date:  1986

5.  Patterns of osteolysis around total hip components inserted with and without cement.

Authors:  B Zicat; C A Engh; E Gokcen
Journal:  J Bone Joint Surg Am       Date:  1995-03       Impact factor: 5.284

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Uncemented total hip arthroplasty in patients 50 years of age or younger.

Authors:  P A Dowdy; C H Rorabeck; R B Bourne
Journal:  J Arthroplasty       Date:  1997-12       Impact factor: 4.757

8.  Ectopic bone formation following low friction arthroplasty of the hip.

Authors:  J DeLee; A Ferrari; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

9.  Long-term fate of uncemented, threaded acetabular components with smooth surface treatment: minimum 10-year follow-up of two different designs.

Authors:  Peter R Aldinger; Marc Thomsen; Martin Lukoschek; Hans Mau; Volker Ewerbeck; Steffen J Breusch
Journal:  Arch Orthop Trauma Surg       Date:  2004-07-07       Impact factor: 3.067

10.  Hip disability and osteoarthritis outcome score (HOOS)--validity and responsiveness in total hip replacement.

Authors:  Anna K Nilsdotter; L Stefan Lohmander; Maria Klässbo; Ewa M Roos
Journal:  BMC Musculoskelet Disord       Date:  2003-05-30       Impact factor: 2.362

View more
  11 in total

1.  The augment-and-modular-cage revision system for reconstruction of severe acetabular defects-two-year clinical and radiographic results.

Authors:  Philip P Roessler; Max Jaenisch; Manuel Kuhlmann; Miriam Wacker; P Johannes Wagenhäuser; Sascha Gravius; Dieter C Wirtz
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  Long-term survivorship of a monoblock long cementless stem in revision total hip arthroplasty.

Authors:  Yannick Herry; Anthony Viste; Hugo Bothorel; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2018-10-01       Impact factor: 3.075

3.  Bousquet dual mobility socket for patient under fifty years old. More than twenty year follow-up of one hundred and thirty one hips.

Authors:  Remi Philippot; Thomas Neri; Bertrand Boyer; Brice Viard; Frederic Farizon
Journal:  Int Orthop       Date:  2017-01-16       Impact factor: 3.075

4.  Total hip arthroplasty with dual mobility cup in osteonecrosis of the femoral head in young patients: over ten years of follow-up.

Authors:  Pierre Martz; Alexandre Maczynski; Sebastien Elsair; Ludovic Labattut; Brice Viard; Emmanuel Baulot
Journal:  Int Orthop       Date:  2016-11-25       Impact factor: 3.075

5.  Long-term outcomes of total hip arthroplasty in patients younger than 55 years: a systematic review of the contemporary literature

Authors:  Xin Yu Mei; Ying Jia Gong; Oleg Safir; Allan Gross; Paul Kuzyk
Journal:  Can J Surg       Date:  2019-08-01       Impact factor: 2.089

6.  An early experience of the use of dual mobility cup uncemented total hip arhroplasty in young patients with avascular necrosis of the femoral head.

Authors:  Sanjay Bhalchandra Londhe; Rahul Khot; Ravi Vinod Shah; Clevio Desouza
Journal:  J Clin Orthop Trauma       Date:  2022-08-22

7.  Better early functional outcome after short stem total hip arthroplasty? A prospective blinded randomised controlled multicentre trial comparing the Collum Femoris Preserving stem with a Zweymuller straight cementless stem total hip replacement for the treatment of primary osteoarthritis of the hip.

Authors:  Jakob van Oldenrijk; Vanessa A B Scholtes; Loes W A H van Beers; Carel H Geerdink; Bob B A M Niers; Wouter Runne; Mohit Bhandari; Rudolf W Poolman
Journal:  BMJ Open       Date:  2017-10-16       Impact factor: 2.692

8.  Adverse local tissue reaction after 2 revision hip replacements for ceramic liner fracture: A case report.

Authors:  Iulian Antoniac; Mihai Negrusoiu; Mihai Mardare; Claudiu Socoliuc; Ancuţa Zazgyva; Marius Niculescu
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

9.  Early results of total hip arthroplasty using dual-mobility cup in patients with osteonecrosis of the femoral head.

Authors:  Chahine Assi; Nadim Kheir; Camille Samaha; Pascal Kouyoumjian; Kaissar Yammine
Journal:  SICOT J       Date:  2018-02-21

10.  Comparing uncemented, hybrid and cemented primary total hip arthroplasty in young patients, a New Zealand Joint Registry study.

Authors:  Alexander Buckenham Boyle; Mark Zhu; Chris Frampton; Andrew Vane; Vaughan Poutawera
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-28       Impact factor: 2.928

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.