Literature DB >> 26753842

Long-term results with the Atlas IIIp elastic cementless acetabular component in total hip replacement.

Paul Yuh Feng Lee1,2,3, Madhu Rachala4, Kar Ho Teoh5, David John Woodnutt4.   

Abstract

PURPOSE: Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries.
METHODS: We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis.
RESULTS: The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening.
CONCLUSIONS: Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate. LEVEL OF EVIDENCE: Therapeutic III; therapeutic study.

Entities:  

Keywords:  Acetabular cup; Altas IIIp; Cementless; Elastic press-fit; Hip arthroplasty; Long-term results

Mesh:

Year:  2016        PMID: 26753842     DOI: 10.1007/s00264-015-3088-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  16 in total

1.  The effects of polyethylene cup thickness on wear of total hip prostheses.

Authors:  H Oonishi; H Iwaki; N Kin; S Kushitani; N Murata; S Wakitani; K Imoto
Journal:  J Mater Sci Mater Med       Date:  1998-08       Impact factor: 3.896

2.  Primary uncemented Harris-Galante acetabular components in patients 50 years old or younger: results at 10 to 12 years.

Authors:  Gavan P Duffy; Branko Prpa; Charles M Rowland; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2004-10       Impact factor: 4.176

3.  Ten-year follow-up of the non-porous Allofit cementless acetabular component.

Authors:  P Zenz; J B Stiehl; H Knechtel; G Titzer-Hochmaier; W Schwagerl
Journal:  J Bone Joint Surg Br       Date:  2009-11

4.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

5.  Early polyethylene wear and osteolysis in cementless total hip arthroplasty: the influence of femoral head size and polyethylene thickness.

Authors:  P C Lee; C H Shih; W J Chen; Y K Tu; C L Tai
Journal:  J Arthroplasty       Date:  1999-12       Impact factor: 4.757

6.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

7.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

8.  Metal-backed acetabular components with conventional polyethylene: a review of 9113 primary components with a follow-up of 20 years.

Authors:  G Hallan; E Dybvik; O Furnes; L I Havelin
Journal:  J Bone Joint Surg Br       Date:  2010-02

9.  High survival in young patients using a second generation uncemented total hip replacement.

Authors:  Marcus R Streit; Kerstin Schröder; Matthias Körber; Christian Merle; Tobias Gotterbarm; Volker Ewerbeck; Peter R Aldinger
Journal:  Int Orthop       Date:  2011-11-24       Impact factor: 3.075

10.  10-year results of the uncemented Allofit press-fit cup in young patients.

Authors:  Marcus R Streit; Stefan Weiss; Franziska Andreas; Thomas Bruckner; Tilman Walker; J Philippe Kretzer; Volker Ewerbeck; Christian Merle
Journal:  Acta Orthop       Date:  2014-05-30       Impact factor: 3.717

View more
  2 in total

1.  Thirteen year follow-up of a cementless femoral stem and a threaded acetabular cup in patients younger than fifty years of age.

Authors:  Jan Schmolders; Grigoris Amvrazis; Peter H Pennekamp; Andreas Christian Strauss; Max Julian Friedrich; Matthias D Wimmer; Yorck Rommelspacher; Dieter Christian Wirtz; Thomas Wallny
Journal:  Int Orthop       Date:  2016-05-30       Impact factor: 3.075

2.  Early aseptic loosening of cementless monoblock acetabular components.

Authors:  Simo S A Miettinen; Tatu J Mäkinen; Inari Laaksonen; Keijo Mäkelä; Heini Huhtala; Jukka Kettunen; Ville Remes
Journal:  Int Orthop       Date:  2016-08-10       Impact factor: 3.075

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.