Dynamic response of the ROSE damping device.

B Kleinman1, S Powell.   

Abstract

Methods used in clinical practice to increase the damping of a transducer hydraulically coupled to an intraarterial blood-pressure monitoring system often decrease the undamped natural frequency of the system. This leads to spuriously high systolic and low diastolic pressure readings. The ROSE damping device is being marketed as a possible solution to the problem. We tested the dynamic response of three different catheter systems, with various pressure-tubing lengths of 1 to 7 feet (30.5 to 213.4 cm), with and without the ROSE damping device. The device was able to substantially increase damping and at the same time maintain the undamped natural frequency. Typically it increased the damping coefficient from a minimum of 0.17 +/- 0.01 to a minimum of 0.33 +/- 0.01, while never significantly decreasing the undamped natural frequency. In testing a sample of 25 devices we did observe, however, a wide variability in damping characteristics among different devices. Damping coefficients ranged between 0.19 and 1.20.

Entities:  

Mesh:

Year:  1989        PMID: 2723705     DOI: 10.1007/BF01617884

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  6 in total

1.  Physiologic recording by modern instruments with particular reference to pressure recording.

Authors:  D L FRY
Journal:  Physiol Rev       Date:  1960-10       Impact factor: 37.312

2.  Some physical aspects of blood pressure, pulse wave, and blood pressure measurements.

Authors:  L H VAN DER TWEEL
Journal:  Am Heart J       Date:  1957-01       Impact factor: 4.749

3.  Accuracy and dynamic response of disposable pressure transducer-tubing systems.

Authors:  P Hunziker
Journal:  Can J Anaesth       Date:  1987-07       Impact factor: 5.063

4.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

5.  Use of a needle valve variable resistor to improve invasive blood pressure monitoring.

Authors:  J H Abrams; M L Olson; J A Marino; F B Cerra
Journal:  Crit Care Med       Date:  1984-11       Impact factor: 7.598

6.  The dynamic responses of liquid-filled catheter systems for direct measurements of blood pressure.

Authors:  T Shinozaki; R S Deane; J E Mazuzan
Journal:  Anesthesiology       Date:  1980-12       Impact factor: 7.892

  6 in total
  1 in total

1.  Intraarterial catheter diameter and dynamic response of arterial pressure monitoring system: a randomized controlled trial.

Authors:  Hyongmin Oh; Suk Hyung Choe; Yoon Jung Kim; Hyun-Kyu Yoon; Hyung-Chul Lee; Hee-Pyoung Park
Journal:  J Clin Monit Comput       Date:  2021-02-01       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.