Literature DB >> 27236816

One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography.

Yuzo Yamasaki1, Michinobu Nagao2, Satoshi Kawanami2, Takeshi Kamitani3, Koji Sagiyama3, Torahiko Yamanouchi3, Ichiro Sakamoto4, Kenichiro Yamamura5, Hidetake Yabuuchi6, Hiroshi Honda3.   

Abstract

OBJECTIVES: To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements.
METHODS: Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test.
RESULTS: Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size.
CONCLUSIONS: 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. KEY POINTS: • Quantification of left-to-right shunting can be performed reliably and accurately by CT. • The sizes of defects and rims can be measured accurately using 256-slice CT. • 256-slice CT permits pretreatment evaluation of ASD non-invasively and comprehensively.

Entities:  

Keywords:  Amplatzer septal occluder; Atrial septal defect; Multislice CT; One-stop shop assessment; Pulmonary to systemic blood flow ratio

Mesh:

Year:  2016        PMID: 27236816     DOI: 10.1007/s00330-016-4407-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  17 in total

1.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

2.  Improvement of automated right ventricular segmentation using dual-bolus contrast media injection with 256-slice coronary CT angiography.

Authors:  Masatoshi Kondo; Michinobu Nagao; Masato Yonezawa; Yuzo Yamazaki; Takashi Shirasaka; Yasuhiko Nakamura; Hiroshi Honda
Journal:  Acad Radiol       Date:  2014-05       Impact factor: 3.173

3.  Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI.

Authors:  Yuzo Yamasaki; Michinobu Nagao; Kenichiro Yamamura; Masato Yonezawa; Yoshio Matsuo; Satoshi Kawanami; Takeshi Kamitani; Ko Higuchi; Ichiro Sakamoto; Yuichi Shiokawa; Hidetake Yabuuchi; Hiroshi Honda
Journal:  Eur Radiol       Date:  2014-08-12       Impact factor: 5.315

4.  Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility.

Authors:  Tain Lee; I-Chen Tsai; Yun-Ching Fu; Sheng-Lin Jan; Chung-Chi Wang; Yen Chang; Min-Chi Chen
Journal:  Pediatr Radiol       Date:  2006-10-12

5.  A low tube voltage technique reduces the radiation dose at retrospective ECG-gated cardiac computed tomography for anatomical and functional analyses.

Authors:  Seitaro Oda; Daisuke Utsunomiya; Yoshinori Funama; Kazuo Awai; Kazuhiro Katahira; Takeshi Nakaura; Yumi Yanaga; Tomohiro Namimoto; Yasuyuki Yamashita
Journal:  Acad Radiol       Date:  2011-05-04       Impact factor: 3.173

6.  Preoperative cardiac computed tomography for demonstration of congenital cardiac septal defect in adults.

Authors:  Hye-Joung Eom; Dong Hyun Yang; Joon-Won Kang; Dae-Hee Kim; Jong-Min Song; Duk-Hyun Kang; Jae-Kwan Song; Joon Bum Kim; Sung-Ho Jung; Suk Jung Choo; Cheol Hyun Chung; Jae Won Lee; Tae-Hwan Lim
Journal:  Eur Radiol       Date:  2014-12-18       Impact factor: 5.315

7.  Predictors of successful transcatheter closure of atrial septal defect by cardiac magnetic resonance imaging.

Authors:  K Durongpisitkul; N L Tang; J Soongswang; D Laohaprasitiporn; A Nanal
Journal:  Pediatr Cardiol       Date:  2003-12-15       Impact factor: 1.655

Review 8.  Percutaneous treatment of patent foramen ovale and atrial septal defects.

Authors:  Jonathan Tobis; Michael Shenoda
Journal:  J Am Coll Cardiol       Date:  2012-10-03       Impact factor: 24.094

9.  Right heart: split-bolus injection of diluted contrast medium for visualization at coronary CT angiography.

Authors:  J Matthias Kerl; James G Ravenel; Shaun A Nguyen; Pal Suranyi; Christian Thilo; Philip Costello; Werner Bautz; U Joseph Schoepf
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

10.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

View more
  1 in total

1.  Evaluation of atrial septal defects with 4D flow MRI-multilevel and inter-reader reproducibility for quantification of shunt severity.

Authors:  Raluca G Chelu; Michael Horowitz; Dominica Sucha; Isabella Kardys; Delphine Ingremeau; Shreyas Vasanawala; Koen Nieman; Jean-Francois Paul; Albert Hsiao
Journal:  MAGMA       Date:  2018-08-31       Impact factor: 2.310

  1 in total